{"product_id":"b-r-x20ps8002-x20-series-power-supply-module","title":"Module d'alimentation série B\u0026R X20PS8002 X20","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eB\u0026amp;R X20PS8002 (X20 PS 8002)\u003c\/strong\u003e is a dedicated power supply module within the X20 system, specifically engineered to provide a stable 24 VDC supply for standalone devices. This module serves as a critical component in ensuring consistent operational voltage across modular automation architectures, effectively isolating supply fluctuations from sensitive control logic. By maintaining a reliable power backbone, the X20PS8002 minimizes the risk of voltage-drop-related system resets or communication errors in demanding industrial environments such as automated assembly lines, process instrumentation, and remote I\/O islands.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eDesigned for high efficiency, the X20PS8002 is optimized for integration into the X20 backplane, providing a robust power output while maintaining a low internal power consumption of 1.34 W. The module is built to handle a nominal 24 VDC input with a wide tolerance of -15% to +20%, allowing it to remain operational during minor supply instability. Integrated diagnostic features, including dedicated status indicators for operating state and module status, provide maintenance personnel with immediate visual confirmation of power delivery health. Its compact design ensures that it occupies minimal cabinet space while delivering the necessary current for peripheral standalone components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eX20PS8002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eB\u0026amp;R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eFunction\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e24 VDC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e24 VDC (-15% \/ +20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eMax Input Current\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e1.34 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the X20PS8002?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is specifically designed to provide a dedicated 24 VDC power source for standalone devices within the X20 ecosystem, ensuring they receive stable power isolated from the main bus supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require special ventilation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the X20PS8002 has low power consumption, standard cabinet ventilation practices should be followed. Ensure that the module is installed in an environment where ambient temperatures stay within specified limits to maximize its service life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I monitor the status of the power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features front-facing LED indicators for operating state and module status. If the status indicator signals an error, the module is likely detecting an input voltage outside of the specified -15% \/ +20% range or an internal fault.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Protection:\u003c\/strong\u003e Although the X20PS8002 is designed for robustness, ensure that the upstream 24 VDC source is protected by a fast-acting fuse or circuit breaker rated to protect the input wiring and the module itself in the event of a short circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Practices:\u003c\/strong\u003e When connecting the 24 VDC input, use appropriately gauged copper wire to minimize voltage drop across the connection. Ensure that all terminals are tightened to the torque specifications provided in the X20 system user manual to prevent intermittent connections due to thermal expansion or cabinet vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e For optimal performance and noise immunity, ensure that the power supply is properly referenced to the system's common ground. Proper grounding minimizes the risk of ground loops, especially in configurations where this module powers sensors or actuators dispersed across a large machine frame.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Default Title","offer_id":53086366531947,"sku":"X20PS8002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/x20ps8002-4tzlzdz3drc.png?v=1776138217","url":"https:\/\/www.plcprotech.com\/fr\/products\/b-r-x20ps8002-x20-series-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}