{"product_id":"beckhoff-cp3915-0010-cp39xx-multi-touch-control-panel","title":"Panneau de contrôle multi-touch CP39xx Beckhoff CP3915-0010","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eServing as a highly resilient human-machine interface for distributed control topologies, the Beckhoff CP3915-0010 brings industrial-grade visualization directly to the field level. This premium control panel combines a robust 15-inch display with capacitive multi-finger touch technology, enclosed within an all-round IP65-rated aluminum housing with a high-durability glass front. Engineered to run seamlessly with the proprietary CP-Link 4 transmission standard, the unit consolidates video signals, USB 2.0 control signals, and power distribution into a single high-speed network infrastructure, enabling clean installations across extended distances without signal degradation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fidelity Display:\u003c\/strong\u003e 15-inch screen operating at a native resolution of 1024 x 768 pixels for clear process visualization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Touch Technology:\u003c\/strong\u003e Projected capacitive touch (PCT) sensor allows multi-finger input tracking, enabling gesture control and dual-hand safety confirmations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCP-Link 4 Integration:\u003c\/strong\u003e Utilizes One Cable Technology (OCT) to transmit DVI, USB 2.0 (100 Mbit\/s), and supply power up to 100 meters over a single Cat.6A cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Environmental Protection:\u003c\/strong\u003e Complete IP65 protection rating provides total dust ingress prevention and resistance to low-pressure water jets from all angles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSturdy Industrial Housing:\u003c\/strong\u003e CNC-milled aluminum housing with a chemically hardened glass front resistant to scratching and chemical exposure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly Lines:\u003c\/strong\u003e Mounting directly onto articulating arms next to robot cells for intuitive localized cell operations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFood \u0026amp; Beverage Processing:\u003c\/strong\u003e Rugged design stands up to standard washdown protocols and localized humidity variations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling \u0026amp; Logistics:\u003c\/strong\u003e Clean overhead installation via standard mounting arms provides reliable status feedback across large sorting hubs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eBeckhoff Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Reference\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCP3915-0010\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eDisplay Size\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e15-inch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eResolution\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTouch Technology\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMulti-finger touch (Projected Capacitive)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCP-Link 4 (via standard Cat.6A cables)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnector Ports\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 x M12 round connectors (IP65-rated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Class\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP65 (all-round)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0 to 50 degC (ambient storage limit: -20 to 60 degC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Configuration\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e4 x M6 threaded holes at 100 x 100 mm pitch on connection block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/th\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e6.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections \u0026amp; Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; font-weight: bold;\"\u003e\n        \u003cth style=\"padding: 0.5rem; width: 30%;\"\u003eConnector Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem;\"\u003eSignal \/ Power Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eM12 Connector (Port 1)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCP-Link 4 connection (transmits USB 2.0, DVI, and OCT Power)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eM12 Connector (Port 2)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eOptional external 24 VDC power supply connection (used when transmitter operates in dual-cable configuration)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUnlike legacy CP-Link 3 architectures which required dedicated PCIe cards in the Industrial PC, the CP39xx series relies on external transmitter modules (such as the CU8802 or CU8803). Ensure that your upstream host PC has a verified compatible transmitter interface. Attempting to drive this panel directly via generic standard USB or display adapters over passive extensions will result in a failure of both the display engine and touch feedback.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIn deployments with severe electromagnetic interference (EMI), such as those located near heavy robotic welding cells or variable frequency drives (VFDs), any interruption in the Cat.6A shielding path can trigger USB dropouts or screen flickering. Always verify end-to-end ground continuity on the external shielding. Do not route the CP-Link 4 cable parallel to high-voltage power conduits without a grounded metal divider barrier.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eWhen operating this control panel via the One Cable Technology (OCT) option, the host transmitter injects 24 VDC directly into the Cat.6A loop. Ensure that the total cable run does not exceed 100 meters, as copper losses on substandard cables can cause the supply voltage to sag below the operational 19.2 VDC lower threshold, leading to unpredictable device resets during thermal cycling.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Verify that the host transmitter module and all primary supply lines are fully de-energized before connecting or disconnecting the M12 round connectors. Hot-plugging CP-Link 4 interfaces during active OCT power distribution can cause internal arc-damage to high-pin-density connectors, leading to permanent transceiver degradation.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the hardware onto your mechanical support bracket or articulating swing-arm system using four M6 bolts tightened into the connection block at a standard 100 x 100 mm orientation. Maintain the recommended tightening torque specified by the arm manufacturer.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eRun a continuously shielded Cat.6A Ethernet line (with rugged, industrial-grade RJ45 or M12 terminations) from the transmitter block inside the control cabinet directly to the control panel's CP-Link 4 interface.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; align-items: center; justify-content: center; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSecure all M12 threaded couplings tightly to ensure moisture-tight sealing. Once mechanical locks are checked, apply primary power to the host system and verify proper operating OS touch calibration.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106446598507,"sku":"CP3915-0010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cp3915-0010-2rnwxlio51g.png?v=1776243804","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-cp3915-0010-cp39xx-multi-touch-control-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}