{"product_id":"beckhoff-cx-2040-n031-0002-cx-2000-series-basic-cpu-module","title":"Module CPU de base série CX 2000 BECKHOFF CX 2040-N031-0002","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCX 2040-N031-0002 (CX2040-N031-0002)\u003c\/strong\u003e is a robust industrial CPU module designed for scalable automation architectures in high-demand environments, including heavy manufacturing, power distribution, and automated logistics. As a core member of the Beckhoff CX 2000 series, this unit provides the computational foundation for sophisticated machine control, ensuring minimal latency and high uptime. By centralizing logic processing and fieldbus interface management, it effectively mitigates the risk of system failures and reduces downtime in critical industrial applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThis module is optimized for serial communication tasks where reliable multi-node networking is required. The integrated RS485 interface utilizes a 9-pin D-sub socket, specifically factory-configured for drop-point applications. The hardware architecture is set to operate without echo, which is the preferred configuration for half-duplex communication in multi-drop bus topologies to prevent signal interference from reflected data. The termination is set to \"off\" by default, allowing engineers the flexibility to apply the necessary bus termination at the physical end of the cable run according to the specific impedance requirements of the communication network.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCX 2040-N031-0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBECKHOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e144 mm x 100 mm x 91 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eInterface Type\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eRS485, 9-pin D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eDrop point, no echo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eTermination\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eOff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eOptimized for low-heat dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"no echo\" configuration mean for my fieldbus network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"no echo\" setting prevents the RS485 transceiver from returning the transmitted data back to the local CPU port. This is standard for 2-wire half-duplex systems to ensure the software does not process its own transmitted data as incoming traffic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the termination set to \"off\" on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis allows for flexible network topology. In a long RS485 bus, termination should only be applied at the two physical endpoints of the cable. Since this module may be installed as a mid-segment drop point, leaving the termination off prevents signal loading issues.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a legacy CX 2040 unit with this version directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenerally, yes, provided the software project and communication settings (baud rate, parity, stop bits) are aligned with the drop-point configuration of this specific hardware revision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I manage heat dissipation in a closed cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is designed for standard convection cooling. Ensure adequate spacing (minimum 50 mm) above and below the module and verify that your cabinet's internal temperature does not exceed 55 deg C.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines and Best Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Topology Management:\u003c\/strong\u003e When using this module in an RS485 multi-drop network, ensure the bus is wired in a daisy-chain fashion. Avoid star or stub configurations, which can cause signal reflections that the \"no echo\" setting cannot fix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Procedures:\u003c\/strong\u003e If this module is located at the absolute end of your RS485 communication line, you must install an external 120 Ohm resistor across the data lines to match the characteristic impedance of the cable, as the internal termination is off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e Always use twisted-pair shielded cable for RS485 communication. Connect the shield to a single common ground point at the control cabinet to prevent ground loops, which are a common cause of intermittent communication errors in industrial settings.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106611650923,"sku":"CX2040-N031-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx2040-n031-0002-y40xti0e2zp.png?v=1776244202","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-cx-2040-n031-0002-cx-2000-series-basic-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}