{"product_id":"beckhoff-cx1030-n060-ethernet-system-interface-module","title":"BECKHOFF CX1030-N060 Module d'interface système Ethernet","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCX1030-N060 (CX1030N060)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-speed system interface expansion module designed for the Beckhoff CX1030 Embedded PC series. This module provides an additional, independent 10\/100 Mbit\/s Ethernet port via a standard RJ45 connection, allowing for physical network separation or expanded connectivity for field-level communication. Measuring only 19 mm in width, the CX1030-N060 attaches directly to the CPU module via the internal system bus, drawing power through the CX1100-xxxx series power supply units. It is a critical component for industrial applications requiring dedicated uplinks to MES\/ERP systems or separate machine-to-machine (M2M) communication channels without overloading the primary CPU network interface.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe CX1030-N060 is engineered to extend the networking capabilities of the CX1030 series while maintaining the modular footprint of the system.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy adding the CX1030-N060, engineers can implement a dual-homed network strategy—using one port for local EtherCAT control and the N060 port for external factory network access, effectively isolating real-time control traffic from general IT traffic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes the high-speed internal system bus for data exchange. It is important to note that this module is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enot combinable with the CX1100-0004\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply unit due to internal bus pinning and resource allocation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporting Category 5 (Cat. 5) cabling, the interface is optimized for short-to-medium distance communication within the control cabinet or between adjacent equipment, with a maximum certified cable length of 20 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCX1030-N060\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBECKHOFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x Ethernet (10\/100 Mbit\/s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 x RJ45\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax. 20 m, Cat. 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVia system bus (CX1100-xxxx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19 mm x 100 mm x 51 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 80 g (Shipping weight 2 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN 61000-6-2\/4 (EMC), EN 60068-2-6\/27 (Vibration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CX1030-N060 be used to run EtherCAT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the hardware supports 100 Mbit\/s Ethernet, this module is primarily intended for standard TCP\/IP communication (Ethernet). For high-performance EtherCAT motion control, it is recommended to use the primary Ethernet ports located on the CX CPU or dedicated EtherCAT master terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is this module incompatible with the CX1100-0004 power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CX1100-0004 is a specialized power supply module that includes its own integrated 4-line display and buttons. The internal bus communication required for the N060 interface conflicts with the resource mapping of the -0004 variant. Ensure a compatible CX1100-0001, -0002, or -0003 is used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable length supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe official specification limits the cable length to 20 meters using Cat. 5 cables. This limitation ensures maximum electromagnetic compatibility and signal timing stability within the CX1030 system bus environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Sequencing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen assembling the CX system, the CX1030-N060 must be mounted on the left side of the CX1100 power supply module. Ensure the PC-104 bus connectors are clean and aligned before pressing the modules together to prevent pin damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain EMC compliance (EN 61000-6-2), route the RJ45 Ethernet cable away from high-voltage power lines and VFD output cables. Use shielded RJ45 connectors to ensure the cable shield is bonded to the module's ground plane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironment Check:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module is rated for 0 to +55 deg C. In high-density cabinets, ensure that the vertical ventilation slots of the CX assembly are not obstructed. Excessive heat can degrade the 10\/100 Mbit\/s signaling performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCX1030-N060\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a cost-effective and space-efficient way to add network redundancy or segmentation to a Beckhoff control system. Its 19 mm width allows it to be added to existing DIN rail layouts with minimal footprint changes. Because it draws power directly from the system bus, it eliminates the need for additional 24 VDC terminal wiring, simplifying the overall electrical design and reducing potential points of failure in high-vibration environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106706415979,"sku":"CX1030-N060","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx1030-n060-crz4axvy3dg.png?v=1776244149","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-cx1030-n060-ethernet-system-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}