{"product_id":"beckhoff-cx2100-0904-cx-series-power-supply-unit","title":"CX2100-0904 | BECKHOFF | Bloc d'alimentation avec onduleur interne pour CX2020 et CX203x","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned to provide stable system power and integrated backup functionality, the \u003cstrong\u003eBeckhoff CX2100-0904\u003c\/strong\u003e serves as a specialized power supply module for CX2020 and CX203x Embedded PCs. This unit features a capacitively integrated uninterruptible power supply (UPS) to protect systems against brief voltage drops and ensure orderly data preservation during power failures. Additionally, the module supports automatic recognition and power distribution to either E-bus or K-bus I\/O terminals, facilitating seamless integration with Beckhoff EtherCAT and Bus Terminal setups.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated, illuminated FSTN display on the front panel provides real-time status updates and diagnostics, enabling efficient local maintenance. Built with a robust housing and spring-loaded terminal connection technology, this module is optimized for industrial control cabinets where vibration resistance and high operational reliability are critical.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCapacitively integrated UPS with 75 As capacity for safe state preservation and system shutdown.\u003c\/li\u003e\n  \u003cli\u003eAutomatic bus system recognition for both K-bus and E-bus (EtherCAT) connections.\u003c\/li\u003e\n  \u003cli\u003eSupplies up to 2 A current to the connected E-bus or K-bus system terminals.\u003c\/li\u003e\n  \u003cli\u003eIlluminated FSTN text display (2 lines x 16 characters) for parameter configuration and system diagnostics.\u003c\/li\u003e\n  \u003cli\u003eVibration-resistant electrical connection via reliable spring-loaded terminal technique.\u003c\/li\u003e\n  \u003cli\u003eDedicated diagnostic LEDs for instant monitoring of Power, I\/O Run, and I\/O Error states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous monitoring and backup for PLC and industrial PC assemblies in factory automation.\u003c\/li\u003e\n  \u003cli\u003ePower management and terminal bus communication in process control environments.\u003c\/li\u003e\n  \u003cli\u003eWind energy systems, packaging machines, and material handling systems requiring high-availability control architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCX2100-0904\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Power Output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE-bus or K-bus, automatic recognition\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Supply (E-bus\/K-bus)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUPS Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCapacitively integrated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUPS Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 As\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Technology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpring-loaded technique (adapter terminal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFSTN display, 2 lines x 16 characters of text, illuminated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDiagnostics LEDs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x PWR, 1 x I\/O Run, 1 x I\/O Err\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.5 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e118 mm x 100 mm x 91 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 1025 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +50 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95 %, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration \/ Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount on a standard 35 mm DIN rail (EN 60715) within an enclosed control cabinet.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Maintain natural convection airflow by leaving at least 30 mm of free space above and below the module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Insert conductors into the spring-loaded terminals using a standard screwdriver tool. Verify secure clamping before applying power.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the DIN rail is correctly connected to the functional earth potential of the cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106430902635,"sku":"CX2100-0904","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx2100-0904-brod2fzi5kh.png?v=1776244227","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-cx2100-0904-cx-series-power-supply-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}