{"product_id":"beckhoff-cx5130-0100-cx5100-embedded-pc","title":"CX5130-0100 | BECKHOFF | PC embarqué avec processeur Intel Atom®","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nProcessing industrial automation logic directly at the control level, the \u003cstrong\u003eBeckhoff CX5130-0100\u003c\/strong\u003e acts as a fanless, DIN-rail mountable control controller equipped with a dual-core \u003cstrong\u003eIntel Atom E3827 processor\u003c\/strong\u003e running at 1.75 GHz. Designed to execute complex PLC, visualization, and motion control tasks within space-constrained control cabinets, this industrial PC features integrated, hardware-level automatic detection for both \u003cstrong\u003eE-bus (EtherCAT)\u003c\/strong\u003e and \u003cstrong\u003eK-bus (Bus Terminals)\u003c\/strong\u003e physical I\/O slices. The system includes 4 GB of internal DDR3 RAM and dual independent Gigabit Ethernet ports, facilitating robust division between OT and IT communication lines. An integrated 1-second UPS leverages onboard ultra-capacitors to guarantee secure persistence of critical operational variables directly to the CFast card slot during unexpected power failures.\n\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli style=\"list-style-type: square; margin-bottom: 0.5rem; color: #2d3748;\"\u003e\n\u003cstrong\u003eIntel Atom E3827 CPU:\u003c\/strong\u003e Dual-core processing architecture clocked at 1.75 GHz for highly deterministic execution cycles.\u003c\/li\u003e\n  \u003cli style=\"list-style-type: square; margin-bottom: 0.5rem; color: #2d3748;\"\u003e\n\u003cstrong\u003e4 GB DDR3 RAM:\u003c\/strong\u003e High-speed internal system memory optimized for heavy automation runtimes and local visual processing.\u003c\/li\u003e\n  \u003cli style=\"list-style-type: square; margin-bottom: 0.5rem; color: #2d3748;\"\u003e\n\u003cstrong\u003eDual Storage Slots:\u003c\/strong\u003e Accommodates one CFast card and one microSD card to isolate operating system installations from application data logging.\u003c\/li\u003e\n  \u003cli style=\"list-style-type: square; margin-bottom: 0.5rem; color: #2d3748;\"\u003e\n\u003cstrong\u003eIntegrated 1-Second UPS:\u003c\/strong\u003e Automatically writes up to 1 MB of persistent variables to the flash media upon detection of main supply loss.\u003c\/li\u003e\n  \u003cli style=\"list-style-type: square; margin-bottom: 0.5rem; color: #2d3748;\"\u003e\n\u003cstrong\u003eHybrid I\/O Backplane:\u003c\/strong\u003e Built-in automatic identification of connected E-bus (EtherCAT Terminals) or K-bus (standard Bus Terminals) systems.\u003c\/li\u003e\n  \u003cli style=\"list-style-type: square; margin-bottom: 0.5rem; color: #2d3748;\"\u003e\n\u003cstrong\u003eComprehensive Connectivity:\u003c\/strong\u003e Equipped with 2 x RJ45 Gigabit Ethernet ports, 1 x DVI-I display interface, and 4 x USB 2.0 peripheral ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli style=\"list-style-type: square; margin-bottom: 0.5rem; color: #2d3748;\"\u003eHigh-speed EtherCAT-based synchronized multi-axis motion control systems.\u003c\/li\u003e\n  \u003cli style=\"list-style-type: square; margin-bottom: 0.5rem; color: #2d3748;\"\u003eIndustrial IoT gateways bridging fieldbus communication networks with cloud-level architectures.\u003c\/li\u003e\n  \u003cli style=\"list-style-type: square; margin-bottom: 0.5rem; color: #2d3748;\"\u003eCompact localized visual machine-to-machine control panels requiring direct, high-definition DVI output.\u003c\/li\u003e\n  \u003cli style=\"list-style-type: square; margin-bottom: 0.5rem; color: #2d3748;\"\u003eHeavy-duty assembly and packaging machine automation requiring reliable, fanless execution in harsh thermal environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Values\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBECKHOFF\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCX5130-0100\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIntel Atom E3827, 1.75 GHz, Dual-Core\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSystem Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4 GB DDR3 RAM (Non-expandable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x CFast card slot, 1 x microSD card slot (Cards not included)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePersistent Storage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIntegrated 1-second UPS (Saves up to 1 MB of data to CFast)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCommunication Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 x RJ45 10\/100\/1000 Mbit\/s, 1 x DVI-I, 4 x USB 2.0\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Supply Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCurrent Feed E-bus\/K-bus\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 A maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e14 W (Typical) \/ 20 W (While charging internal UPS)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSystem Diagnostics\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x Power, 1 x TC Status, 1 x Flash Access, 2 x Bus Status LEDs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNo operating system pre-installed\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eControl Software\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNo TwinCAT pre-installed\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTwinCAT 3 Platform Level\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePerformance (Level 40)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-25 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePhysical Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e142 mm x 100 mm x 92 mm (W x H x D)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUnit Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1095 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eInterface ID\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eConnector Type\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunctional Assignment \/ Wiring Circuit\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eX101 \/ X102\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRJ45\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDual independent Gigabit Ethernet interfaces for OT\/IT control connection.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eX201\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDVI-I\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVisual output for displays\/HMIs (supports analog VGA via adapter).\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUSB 1...4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUSB Type-A\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4 x USB 2.0 ports for mouse, keyboard, or system diagnostic storage devices.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eX401\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePower Connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePrimary 24 V DC power input connection point, functional ground, and I\/O bus power lines.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe CX5130-0100 is a blank hardware configuration, meaning it does not include a pre-installed operating system or TwinCAT runtime license. This specific variant is standard for systems integrators who intend to load specialized, lightweight Linux kernels or who possess existing TwinCAT licenses to install manually. For applications requiring an out-of-the-box Windows environment, look to the CX5130-0120 (Windows Embedded Compact 7) or the CX5130-0150 (Windows 10 IoT Enterprise) modules to minimize setup preparation.\n\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhile the integrated 1-second UPS utilizes highly durable, maintenance-free ultra-capacitors instead of standard lead-acid or lithium chemistry, it is only engineered to support the preservation of up to 1 MB of marked persistent variables (\u003ccode\u003eVAR PERSISTENT\u003c\/code\u003e) during a sudden power event. It does *not* provide backup power to continue operating the CPU or visual interface. If you run complex disk-write processes or databases on the system, ensure your applications are optimized to handle sudden shutdowns without corrupting primary CFast partition tables. Always specify industrial-grade Beckhoff CFast cards with high write-endurance metrics to guarantee system stability.\n\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen powering a mixed stack of standard K-bus and high-performance E-bus terminals, verify the total current draw of your slice terminals. Although the CX5130-0100 is capable of supplying up to 2 A directly to the internal terminal bus, high-density analog modules or high-frequency digital units can quickly exceed this rating. If your aggregate current calculation exceeds 2 A, you must isolate the bus power and insert a dedicated power feed terminal (such as an EL9410) down-line to maintain stable terminal bus communication. Always hook up the functional earth (FE) terminal on the primary CX power supply block directly to your main backplate ground busbar to minimize high-frequency electromagnetic interference.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL SAFETY WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Isolate all high-voltage and low-voltage field power distribution lines prior to mounting or dismounting the hardware. Failure to switch off the 24 V DC power supply line can lead to electrical arcing, which damages the internal terminal contact pins and risks immediate diagnostic processor failure on the main unit.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the CX5130 unit securely on an grounded, horizontal DIN rail (EN 60715, 35 mm) by locking the lower mounting latches firmly onto the rail geometry.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsert a compatible, formatted CFast card loaded with your chosen operating system and execution software into the primary drive bay located beneath the cover door.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign and connect the terminal block slices (E-bus or K-bus) onto the right-hand bus interface. Verify that the interlocking lateral locking mechanisms engage fully with a click sound.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 15px;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 24 V DC input wires to the front X401 terminal block. Tighten the wire cage clamps securely and ground the chassis via the functional earth tab to ensure proper noise immunity.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106442043755,"sku":"CX5130-0100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx5130-0100-naar4isfnjw.png?v=1776244275","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-cx5130-0100-cx5100-embedded-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}