{"product_id":"beckhoff-cx5130-0122-cx5100-series-embedded-pc","title":"CX5130-0122 | BECKHOFF | Module CPU","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nExecuting high-performance automation control tasks directly at the machine level, the \u003cstrong\u003eBeckhoff CX5130-0122\u003c\/strong\u003e functions as a robust, DIN-rail mountable Embedded PC equipped with an Intel Atom E3827 dual-core processor. This unit integrates dual independent Gigabit Ethernet interfaces and a built-in 1-second UPS to guarantee data integrity during sudden power disruptions.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntel Atom E3827 Processor:\u003c\/strong\u003e Dual-core execution running at 1.75 GHz for deterministic control and multi-tasking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Storage Architecture:\u003c\/strong\u003e Dual slots supporting CFast and microSD cards for operating system and user data storage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated 1-Second UPS:\u003c\/strong\u003e Capacitive backup system that writes up to 1 MB of persistent data to the CFast card upon power failure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Gigabit Ethernet:\u003c\/strong\u003e Two independent RJ45 ports (10\/100\/1000 Mbit\/s) to isolate fieldbus traffic from higher-level network communications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Bus Recognition:\u003c\/strong\u003e Auto-detects and interfaces with either E-bus (EtherCAT Terminals) or K-bus (Standard Bus Terminals).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Motion Control:\u003c\/strong\u003e Real-time synchronization of multi-axis servo systems via EtherCAT.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDistributed Control Systems:\u003c\/strong\u003e Compact control cabinet deployment in manufacturing, packaging, and assembly lines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial IoT Gateways:\u003c\/strong\u003e Edge computing tasks requiring local data processing and secure cloud connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCX5130-0122\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIntel Atom E3827 (2 Cores, 1.75 GHz)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSystem Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4 GB DDR3 RAM (Non-expandable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eFlash Memory Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x CFast slot, 1 x microSD slot (Cards not included)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePersistent Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIntegrated 1-second UPS (1 MB on CFast card)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eI\/O Bus Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eE-bus (EtherCAT) or K-bus (Bus Terminals), automatic recognition\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eBus Current Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 A maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e14 W typical, 20 W maximum (during UPS charging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTwinCAT Platform Level\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePerformance (Platform Level 40)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-25 degC to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-40 degC to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e142 mm x 100 mm x 92 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1095 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInterface \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e2 x RJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e10\/100\/1000 Mbit\/s independent Ethernet interfaces for network separation.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e1 x DVI-I\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eConnection for external Beckhoff Control Panel or standard digital\/analog monitor.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e4 x USB 2.0\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePeripheral connections for input devices, flash drives, or external hardware.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePower Terminal\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 V DC power input connection with integrated ground terminal.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe CX5130-0122 is positioned within the CX5100 series as a dual-core alternative to the single-core CX5120 and the quad-core CX5140. It operates at TwinCAT 3 Platform Level 40 (Performance). Ensure that your TwinCAT runtime licenses are compiled specifically for Platform Level 40 to avoid deployment errors.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe integrated 1-second UPS relies on internal capacitive storage to write up to 1 MB of persistent data to the CFast card. If the CFast card is replaced with a non-industrial grade card lacking high write-endurance, or if the \u003ccode\u003eFB_S_UPS\u003c\/code\u003e function block is not properly called in the TwinCAT PLC project, persistent data will not be saved during a power loss.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen transitioning between E-bus and K-bus terminals, ensure the system is completely powered down. The CX5130 automatically detects the bus type on startup. If the bus terminal line is not terminated with an end terminal (such as KL9010 or EL9011), the CPU will flag a bus error and refuse to enter Run mode.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    DANGER: HIGH RISK OF ELECTRICAL SHOCK AND COMPONENT DAMAGE. Always isolate all 24 V DC power sources before mounting, wiring, or inserting\/removing CFast cards. Failure to de-energize the system can corrupt the operating system image on the flash media or damage the internal E-bus\/K-bus interface circuitry.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eMount the CX5130 vertically on a standard 35 mm DIN rail (EN 60715), ensuring at least 30 mm of free space above and below the unit for natural convection cooling.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the functional ground terminal directly to the low-impedance system ground plane to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eInsert a compatible, pre-configured Beckhoff CFast card containing the operating system and TwinCAT runtime into the designated slot.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the 24 V DC power supply to the power input terminals, verifying correct polarity before switching on the main breaker.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106448138603,"sku":"CX5130-0122","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx5130-0122-vkl1lnljkxd.png?v=1776244281","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-cx5130-0122-cx5100-series-embedded-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}