{"product_id":"beckhoff-ep2308-0002-ep-series-ethercat-box","title":"BECKHOFF EP2308-0002 Boîtier EtherCAT Série EP","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eEP2308-0002 (EP23080002)\u003c\/strong\u003e is a high-performance EtherCAT Box module from the Beckhoff EP series, designed for decentralized I\/O applications in harsh industrial environments. By combining 4 digital inputs and 4 digital outputs within a rugged, IP67-rated housing, this module allows for direct field installation without the need for additional control cabinets. This robust design significantly reduces cabling complexity and installation time, making it an ideal solution for modular machine concepts in industries such as automotive manufacturing, material handling, and large-scale packaging lines where minimizing system downtime is paramount.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe EP2308-0002 is engineered for high-speed communication via the EtherCAT protocol, utilizing two shielded M8 sockets for seamless daisy-chaining. The digital inputs adhere to EN 61131-2 Type 3 specifications, ensuring compatibility with a wide range of standard industrial sensors. On the output side, each of the four channels supports a maximum current of 0.5 A and is individually protected against short circuits, ensuring that a single localized fault does not compromise the entire I\/O block. The module includes integrated sensor supply from the control voltage, with short-circuit protection provided for the total supply load.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEP2308-0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBECKHOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4 Inputs + 4 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter\u003c\/td\u003e\n\u003ctd\u003e3.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ IP66 \/ IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003eM12 x 1 (5-pin), M8 (4-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the EP2308-0002 suitable for outdoor or wash-down applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the module is rated IP65, IP66, and IP67, making it highly resistant to dust and moisture ingress, suitable for demanding environments including wash-down zones.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the individual short-circuit protection work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach output channel features an independent electronic circuit that monitors current draw. If a short circuit occurs on a specific output, only that channel will shut down while the others remain operational, minimizing machine downtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in potentially explosive atmospheres?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the module carries the ATEX marking II 3 G Ex nA IIC T4 Gc, permitting its use in Category 3G hazardous areas.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Use high-quality shielded M12 and M8 connectors to maintain the IP67 rating and ensure electromagnetic compatibility. Always ensure that the connectors are tightened to the manufacturer's specified torque to prevent liquid ingress during high-pressure cleaning cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-Chain Topology:\u003c\/strong\u003e The EP2308-0002 supports EtherCAT daisy-chaining via M8 sockets. When planning your network, ensure the total current consumption does not exceed the capacity of the power supply cabling used to feed the M8 power sockets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal Integrity:\u003c\/strong\u003e Given the 3.0 ms input filter, this module is optimized for standard sensor applications. If your process requires high-speed pulse counting or extremely fast signal acquisition, consider evaluating the signal transition times to ensure the 3.0 ms latency meets your application requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106605654379,"sku":"EP2308-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ep2308-0002-alyb15bhakp.png?v=1776244650","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-ep2308-0002-ep-series-ethercat-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}