{"product_id":"beckhoff-il2301-b310-fieldbus-box-coupler-box","title":"Boîtier coupleur de terrain BECKHOFF IL2301-B310","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for decentralized industrial automation networks, the \u003cstrong\u003eIL2301-B310\u003c\/strong\u003e functions as a robust \u003cstrong\u003ePROFIBUS DP coupler box\u003c\/strong\u003e within the Beckhoff Fieldbus Box range. This high-performance module serves as an IP-Link gateway, allowing standard decentralized extension modules to interface directly with a PROFIBUS DP fieldbus network. Built to operate in harsh machine-level environments, this coupler box eliminates the need for protective control cabinets by integrating advanced diagnostic functions and rugged hardware routing directly onto the machine frame.\u003c\/p\u003e\n\n\u003cp\u003eThe module automatically detects transfer rates up to 12 Mbaud and supports DP-V1 extensions, providing flexible integration options and precise parameterization via the Beckhoff KS2000 configuration software or the master PLC controller. This ensures optimal communication efficiency and minimal configuration overhead in complex multi-node network topologies.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomatic baud rate detection up to 12 Mbaud for seamless network integration.\u003c\/li\u003e\n  \u003cli\u003eHardened industrial housing rated at IP65, IP66, and IP67 for direct wet and dusty environment placement.\u003c\/li\u003e\n  \u003cli\u003eIntegrated IP-Link fiber-optic interface for high-speed localized system expansion.\u003c\/li\u003e\n  \u003cli\u003eSupport for DP-V1 extensions enabling sophisticated parameterization and advanced diagnostic workflows.\u003c\/li\u003e\n  \u003cli\u003eCompact M12 interface for reliable PROFIBUS DP connection and minimized physical footprint.\u003c\/li\u003e\n  \u003cli\u003eM8 power supply design with upstream feed and downstream loop-through connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive manufacturing and assembly lines.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed packaging machinery and sorting systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eFood and beverage production facilities requiring frequent high-pressure washdowns.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eBeckhoff Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eIL2301-B310\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Series\u003c\/strong\u003e\n      \u003ctd\u003eFieldbus Box (IP-Link Coupler)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\n      \u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\n      \u003ctd\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\n      \u003ctd\u003eVia KS2000 software or master controller (DP-V1 supported)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eFieldbus Interface\u003c\/strong\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eTransmission Medium\u003c\/strong\u003e\n      \u003ctd\u003eShielded copper cable, 2 x 0.25 mm2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eControl Voltage\u003c\/strong\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eLoad Voltage\u003c\/strong\u003e\n      \u003ctd\u003eDependent on connected I\/O extension type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Supply Connections\u003c\/strong\u003e\n      \u003ctd\u003eFeed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInternal Current Consumption\u003c\/strong\u003e\n      \u003ctd\u003e85 mA + sensor load (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eCertifications\u003c\/strong\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector \/ Interface\u003c\/th\u003e\n      \u003cth\u003ePin\/Socket Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n      \u003ctd\u003eM12 Socket, 5-pin, B-coded\u003c\/td\u003e\n      \u003ctd\u003eFieldbus communication link\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Feed\u003c\/td\u003e\n      \u003ctd\u003eM8 Male, 4-pin\u003c\/td\u003e\n      \u003ctd\u003e24 V DC control and load power input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Downstream\u003c\/td\u003e\n      \u003ctd\u003eM8 Female, 4-pin\u003c\/td\u003e\n      \u003ctd\u003e24 V DC loop-through to adjacent modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIP-Link\u003c\/td\u003e\n      \u003ctd\u003eFiber-optic sockets\u003c\/td\u003e\n      \u003ctd\u003eConnection to Fieldbus Box extension modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSecurely mount the module directly to the machinery frame or mounting plate using appropriate M4 screws.\u003c\/li\u003e\n  \u003cli\u003eEnsure all M12 and M8 protective caps or cables are fully tightened to a torque specified for IP67 compliance.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum bending radius for the IP-Link fiber-optic connection cables to avoid signal degradation.\u003c\/li\u003e\n  \u003cli\u003eUse shielded, twisted-pair copper cables for PROFIBUS connections to protect against electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106472583531,"sku":"IL2301-B310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/il2301-b310-0idcdchvgsr.png?v=1776244844","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-il2301-b310-fieldbus-box-coupler-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}