{"product_id":"beckhoff-ip1002-b810-fieldbus-box-8-channel-digital-input-module","title":"IP1002-B810 | Beckhoff | Boîtier Fieldbus","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDecentralized signal acquisition on machine frames and production lines is executed reliably by the \u003cstrong\u003eBeckhoff IP1002-B810\u003c\/strong\u003e Fieldbus Box. This device gathers binary control signals from up to eight digital sensors and transmits them over a point-to-point RS232 interface to the master controller. Housed in a robust, fully-sealed polyamide shell, the \u003cstrong\u003eIP1002-B810\u003c\/strong\u003e does not require a protective sub-cabinet, enabling direct machine-mount installation in heavy industrial settings. Key features include an integrated 3.0 ms input filter to prevent contact bounce and standard M12 screw-type connection points for rugged sensor field-wiring.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e8 Digital Inputs:\u003c\/strong\u003e Supports direct connection of standard 24 V DC binary sensors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRS232 Serial Interface:\u003c\/strong\u003e Peer-to-peer communication protocol with selectable data transfer rates up to 38.4 kbaud.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Sealed Housing:\u003c\/strong\u003e Highly durable PA6 polyamide design conforms to IP65, IP66, and IP67 protection classes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Filtering:\u003c\/strong\u003e Integrated 3.0 ms hardware filter to suppress signal noise and contact chatter.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Mounting:\u003c\/strong\u003e Two pre-drilled 3.5 mm structural fixing holes for direct M3 screw attachment to machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDistributed packaging machine automation systems.\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling control networks.\u003c\/li\u003e\n  \u003cli\u003eWet process areas requiring high ingress protection ratings.\u003c\/li\u003e\n  \u003cli\u003eDedicated serial peer-to-peer data logging configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; width: 40%;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; width: 60%;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBeckhoff Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Reference\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP1002-B810\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFieldbus Box Digital Input Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNumber of Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8 digital inputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInterface Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRS232 (open, documented protocol)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eData Transfer Rates\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e9.6 kbaud, 19.2 kbaud, 38.4 kbaud (default)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNominal Input Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e\"0\" Signal Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-3 to +5 V (EN 61131-2, type 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e\"1\" Signal Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e11 to 30 V (EN 61131-2, type 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Filter Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.0 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBox Current Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e45 mA + sensor current (max 0.5 A total)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Supply Connections\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFeed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBus Interface Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSensor Connections\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eM12, screw-type connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePA6 (Polyamide)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eIngress Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-25 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eApprovals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCE, UL\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eApprox. 210 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; width: 30%;\"\u003eConnector\/Terminal\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; width: 70%;\"\u003eFunction \/ Pin Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eM8 Power Feed (Male)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 1: +24 V DC Control Voltage (US), Pin 2: +24 V DC Load Voltage (UP), Pin 3: GND (US), Pin 4: GND (UP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eM8 Downstream (Female)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDaisy-chain connection to downstream modules (US, UP, GND US, GND UP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eM12 Bus Interface (B-coded)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRS232 Serial communication lines (RXD, TXD, GND interface connections)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IP1002-B810 model relies on a standard RS232 peer-to-peer connection, which is distinct from the fieldbus-specific IP1002 network modules (such as CANopen or PROFIBUS variants). When configuring the serial link, ensure the controller's serial port parameters match the module's default baud rate of 38.4 kbaud. Standard configuration tasks can be managed directly using Beckhoff's KS2000 software interface via the specified programming adapters.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause RS232 is an unbalanced communication interface, the maximum length of the serial connection cable is strictly limited to 15 meters. Exceeding this distance or using low-grade unshielded cables in high-interference environments (e.g., adjacent to variable frequency drives) will lead to transmission errors and module timeouts. Ensure that the total current draw of connected sensors does not exceed the short-circuit protected limit of 0.5 A across the module.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen routing the control cables, use shielded copper wiring (2 x 0.25 mm²) specifically rated for RS232 transmissions. Ensure the shield is grounded properly on the host controller side. For the M8 power distribution daisy chain, verify that the cumulative control voltage (US) draw of all downstream modules does not exceed the contact rating of the feed connectors, which is typically capped at 4 A.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to mounting or performing any wiring work on the Fieldbus Box, ensure all power sources—both control voltage (US) and auxiliary load voltage (UP)—are fully de-energized. Failure to isolate power can result in terminal damage, sensor damage, or unexpected system state transitions.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003e\n      \u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Secure the IP1002-B810 to a flat machine surface using two M3 screws through the 3.5 mm diameter mounting holes. Tighten to the recommended torque spec for your mounting substrate.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003e\n      \u003cstrong\u003eRS232 Bus Connection:\u003c\/strong\u003e Insert the B-coded 5-pin M12 bus cable into the communication port. Hand-tighten the screw coupling to secure the IP67-rated seal.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003e\n      \u003cstrong\u003ePower Feed Integration:\u003c\/strong\u003e Connect the incoming 24 V DC power source to the 4-pin M8 male connector. If daisy-chaining, run an M8 cable from the female downstream port to the next fieldbus module.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 15px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 30px; height: 30px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003e\n      \u003cstrong\u003eI\/O Sensor Termination:\u003c\/strong\u003e Connect the 8 digital sensors to the respective M12 peripheral connections. Seal all unused ports with M12 protective caps to prevent fluid ingress and maintain the IP67 rating.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106489393515,"sku":"IP1002-B810","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1002-b810-2z0dyhsmbua.png?v=1776244877","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-ip1002-b810-fieldbus-box-8-channel-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}