{"product_id":"beckhoff-ip1010-b518-fieldbus-box-digital-input-module","title":"IP1010-B518 | Beckhoff | Boîtier bus de terrain","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eConfigured for direct machine mounting without a control cabinet, the \u003cstrong\u003eBeckhoff IP1010-B518\u003c\/strong\u003e serves as a robust \u003cstrong\u003eCANopen digital input module\u003c\/strong\u003e within the modular Fieldbus Box system. This dust-proof and water-resistant unit acquires binary control signals from the physical process level and transmits them to the higher-level controller via an integrated CANopen fieldbus interface. Featuring 8 distinct digital input channels with a fast 0.2 ms input filter, it is optimized for high-speed signal processing and automated system diagnostics. The connection design utilizes space-saving Ø8 mm (M8) snap-in circular connectors, while physical network wiring is streamlined through an integrated T-connector for straightforward bus looping.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8-channel digital input configuration for 24 V DC sensor signals.\u003c\/li\u003e\n  \u003cli\u003eRapid signal acquisition utilizing a integrated 0.2 ms input filter.\u003c\/li\u003e\n  \u003cli\u003eSeamless system integration via the standard CANopen protocol.\u003c\/li\u003e\n  \u003cli\u003eIntegrated T-connector for direct, loop-through bus cabling without external splitters.\u003c\/li\u003e\n  \u003cli\u003eRugged IP67-rated enclosure suitable for harsh industrial environments.\u003c\/li\u003e\n  \u003cli\u003eM8 (Ø8 mm) snap-in connections for swift, tool-free sensor wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized manufacturing automation systems.\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling lines.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly and robotic work cells.\u003c\/li\u003e\n  \u003cli\u003ePackaging and food processing machinery requiring washdown-capable IP67 equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP1010-B518\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCANopen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 digital inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 x M8 (Ø8 mm) snap-in sockets, 3-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eM8 Pin Number\u003c\/th\u003e\n      \u003cth\u003eSignal Assignment\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n      \u003ctd\u003e+24 V DC Sensor Supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e3\u003c\/td\u003e\n      \u003ctd\u003e0 V (GND)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n      \u003ctd\u003eInput Signal (DI)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the module directly to the machine frame or aluminum profiles using the integrated mounting holes.\u003c\/li\u003e\n  \u003cli\u003eTo maintain the IP67 protection rating, ensure all unused M8 sensor sockets are fitted with protective screw\/snap-in caps.\u003c\/li\u003e\n  \u003cli\u003eVerify that the CANopen network termination resistors are correctly positioned at the physically first and last nodes of the segment.\u003c\/li\u003e\n  \u003cli\u003eAvoid routing high-voltage power cables in close parallel proximity to the fieldbus communication lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106460721515,"sku":"IP1010-B518","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1010-b518-0ziotxv3r55.png?v=1776244881","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-ip1010-b518-fieldbus-box-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}