{"product_id":"beckhoff-ip1011-b730-fieldbus-box-8-channel-digital-input-module","title":"IP1011-B730 | Beckhoff | Boîtier Fieldbus","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for decentralised acquisition of binary signals in harsh physical environments, this industrial IO module interfaces directly with serial fieldbus systems. The \u003cstrong\u003eBeckhoff IP1011-B730\u003c\/strong\u003e distributes 8 digital inputs across a field-level footprint, transmitting state data over \u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e to standard industrial controllers. Operating at \u003cstrong\u003e24 V DC\u003c\/strong\u003e, it features short-circuit protected sensor power distribution and rapid \u003cstrong\u003e0.2 ms input filtering\u003c\/strong\u003e suitable for high-speed tracking.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli\u003e8 digital input channels with M8 screw-type connection interfaces\u003c\/li\u003e\n  \u003cli\u003eIntegrated Modbus fieldbus interface supporting RTU and ASCII protocols\u003c\/li\u003e\n  \u003cli\u003eWide-range input voltage compliance (-15% to +20%) conforming to EN 61131-2 Type 2\u003c\/li\u003e\n  \u003cli\u003eFull IP65\/66\/67 environmental protection class for control cabinet-free installation\u003c\/li\u003e\n  \u003cli\u003eFlexible address configuration via manual rotary switches or KS2000 software\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 20px;\"\u003e\n  \u003cli\u003eField-level sensor aggregation in automotive manufacturing and assembly lines\u003c\/li\u003e\n  \u003cli\u003eDistributed I\/O processing in material handling conveyor networks\u003c\/li\u003e\n  \u003cli\u003eRemote digital signal monitoring in municipal water and wastewater facilities\u003c\/li\u003e\n  \u003cli\u003eOn-machine wiring integration for packaging, sorting, and palletizing machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 8px;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP1011-B730\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eFieldbus Box\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumber of Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eM8 (Screw Type)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Filter\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.2 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNominal Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e\"0\" Signal Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-3 to +5 V (EN 61131-2, Type 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e\"1\" Signal Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e11 to 30 V (EN 61131-2, Type 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003etyp. 6 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSensor Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003emax. 0.5 A (short-circuit proof, total)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eModbus RTU \/ ASCII\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eBaud Rates\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 baud\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eBus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eBox Supply Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e45 mA + sensor current\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eControl voltage \/ fieldbus: Yes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMaterial\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePA6 (Polyamide)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-25 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eapprox. 210 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 8px;\"\u003eInterface Connection\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eConnector Type\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eFunction Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFeed Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x M8 male socket, 4-pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eControl voltage (24 V DC) supply input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDownstream Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eControl voltage loop-through to adjacent modules\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFieldbus Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eModbus RTU\/ASCII communication connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDigital Inputs (0-7)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8 x M8 screw-type sockets\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3-wire sensor connections (24V DC, GND, Signal)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IP1011-B730 belongs to the Beckhoff Modbus Fieldbus Box family. It serves as a direct functional match for older IP1011 configurations using RS485 physical layer communication. While fully compatible with the standard TwinCAT software environments via Modbus master libraries, addressing must be configured manually via rotary switches or the KS2000 configuration cable interface when swapping units from different legacy systems.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe total cumulative sensor supply current across all 8 M8 input connections must not exceed 0.5 A. Exceeding this combined rating trips the internal short-circuit protection, temporarily disabling power to all attached sensors. When deploying the unit in environments with significant electrical interference, ensure the RS485 shielding is properly grounded through the B-coded M12 connector casing to avoid message packet drops or CRC errors over Modbus.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways configure the station address before mounting the module in inaccessible areas. The address switches are located beneath the clear protective cover on the face of the unit. Ensure the integrated elastomeric seal is properly seated in its groove when refastening the cover; failure to align this gasket compromises the IP67 moisture seal and may lead to fluid ingress and internal board corrosion.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all primary control and load power supplies before starting physical installation or wiring modifications. Failure to disconnect system power can cause terminal arcing, electrical shock, and damage to the internal bus transceiver circuitry.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003ePosition the module onto a flat mounting surface and secure using two M3 screws through the 3.5 mm diameter fixing holes. Do not exceed 0.5 Nm of torque.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eRemove the protective address cover, configure the network address via the rotary switches, and carefully re-secure the cover ensuring seal alignment.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the B-coded M12 Modbus cable and secure the coupling ring to maintain the environmental IP rating.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the 4-pin M8 power feed cable. If looping power to an adjacent module, connect the M8 downstream cable.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 0.75rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003ePlug in the M8 digital input sensor lines. Ensure unused ports are sealed with protective caps to maintain environmental integrity.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106491130219,"sku":"IP1011-B730","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1011-b730-gjf5gvim4wj.png?v=1776244892","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-ip1011-b730-fieldbus-box-8-channel-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}