{"product_id":"beckhoff-ip1012-b510-fieldbus-box-8-channel-digital-input-module","title":"IP1012-B510 | Beckhoff | Boîte de bus de terrain","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProcessing eight digital inputs directly in the field, the \u003cstrong\u003eBeckhoff IP1012-B510\u003c\/strong\u003e provides high-speed signal acquisition for CANopen networks without requiring a protective control cabinet. This distributed I\/O module features a robust, fully-sealed \u003cstrong\u003eIP67\u003c\/strong\u003e enclosure, making it ideal for decentralized automation topologies where space is limited and environment conditions are harsh. With a rapid \u003cstrong\u003e0.2 ms input filter\u003c\/strong\u003e and integrated sensor power supply, the module interfaces seamlessly with proximity sensors, limit switches, and photoelectric sensors to transmit precise state changes over the CANopen industrial protocol.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Signal Capture:\u003c\/strong\u003e 0.2 ms digital input hardware filter prevents contact bounce and ensures deterministic state capture.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDecentralized CANopen Node:\u003c\/strong\u003e Integrates directly into CANopen networks with support for up to 16 send and 16 receive PDOs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardened IP67 Housing:\u003c\/strong\u003e Fully encapsulated polyamide structure resistant to water jets, dust, and mechanical vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtected Sensor Power Supply:\u003c\/strong\u003e Delivers up to 0.5 A total auxiliary power to connected sensors with complete short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect M12 Connection:\u003c\/strong\u003e Standardized industrial connection points minimize field wiring errors and optimize signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly Lines:\u003c\/strong\u003e Distributed sensor gathering on robotic arms and transfer stations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConveyor and Material Handling Systems:\u003c\/strong\u003e Direct mounting on structural profiles to track package routing and sensor states.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFood \u0026amp; Beverage Processing:\u003c\/strong\u003e Washdown-heavy environments requiring moisture-resistant remote I\/O blocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e Compact field deployment to minimize cabinet size and reduce routing costs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.95rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBeckhoff Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP1012-B510\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFieldbus Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCANopen (automatic detection from 10 kbaud to 1 Mbaud)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumber of Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8 digital inputs (type 2 according to EN 61131-2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Connections\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eM12, screw type\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNominal Input Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Filter Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.2 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e\"0\" Signal Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-3 V to +5 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e\"1\" Signal Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e11 V to 30 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTypically 6 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSensor Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMax. 0.5 A total, short-circuit proof\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eBus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eControl voltage \/ fieldbus: 500 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCurrent Consumption (Us)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e45 mA + sensor load (max. 0.5 A)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-25 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePA6 (Polyamide)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.0 Kg (including heavy industrial packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; font-size: 0.95rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003ePin \/ Terminal Assignment\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd rowspan=\"5\" style=\"padding: 8px; font-weight: bold; vertical-align: top;\"\u003eCANopen Bus (M12 Male, 5-pin)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eShield \/ Functional Earth\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eV+ (Bus supply voltage)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eV- (Bus reference potential)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCAN_H (Data High)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCAN_L (Data Low)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd rowspan=\"4\" style=\"padding: 8px; font-weight: bold; vertical-align: top;\"\u003ePower Supply Feed (M8 Male, 4-pin)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e+24 V DC control voltage (Us)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e+24 V DC auxiliary load voltage (Up)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGND (Us)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGND (Up)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd rowspan=\"5\" style=\"padding: 8px; font-weight: bold; vertical-align: top;\"\u003eDigital Inputs (M12 Sockets 1-4)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e+24 V DC sensor supply (derived from Us)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDigital Input Channel B (Even numbers: 2, 4, 6, 8)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGND (Us)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDigital Input Channel A (Odd numbers: 1, 3, 5, 7)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePin 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eFunctional Earth (FE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IP1012-B510 utilizes standard CANopen architecture. If compatibility requirements demand an alternate physical footprint, the IP1002-B510 utilizes the same technical structure but implements 8 x M8 connections instead of the M12 format. For migration from older physical nodes, verify that your CANopen network master (such as Beckhoff FC5101 or EL6751) is configured to parse the 8-bit process image. If replacing a PROFIBUS node (IP1012-B310) with this model, the complete trunk-line cabling must be updated to conform to CAN physical layer standards.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eA common point of field failure is the total sensor supply limit. The module provides a maximum of 0.5 A across all 8 channels. When using active proximity sensors, calculate the total current draw. If high-draw photoelectric sensors exceed 500 mA combined, the internal self-resetting fuse will trip, cutting sensor power. If thermal degradation occurs due to direct sunlight or ambient temperature nearing +55 degC, the internal resistance of the fuse increases, lowering this trip threshold. Use an auxiliary power distributor if high-load sensors are required.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBaud rate and Node ID settings are configured via rotary address switches located underneath the protective transparent screw-cap. Ensure these rotary switches are set before powering the network. Always replace and tighten the protective cap with its integrated rubber gasket to maintain the IP67 moisture and dust seal. When installing long bus segments, verify that a 120-Ohm CAN termination resistor is applied to the final physical node on the network to prevent signal reflections and packet drops.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all control and auxiliary power networks before performing any physical installation or maintenance. Hot-plugging industrial sensors or bus lines under load can cause voltage spikes, damaging the internal optical isolation circuitry of the CANopen communications block.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the Fieldbus Box to a flat, vibration-free surface using the two 3.5 mm integrated mounting holes. Secure with M3 bolts to a maximum tightening torque of 0.8 Nm.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify that the CANopen network speed matches your PLC configuration before adjusting the node address rotary switches. Securely tighten the protective faceplate cap afterward.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the incoming 24 V DC power using the 4-pin M8 male connector. If daisy-chaining multiple modules, utilize the downstream female M8 connector, ensuring the aggregate current does not exceed the limit of the primary supply line.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAttach M12 sensor cables. Seal any unused M12 and M8 ports with protective plastic screw-plugs to retain the system's IP67 ingress rating.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106522620267,"sku":"IP1012-B510","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1012-b510-chgri5dcw20.png?v=1776244896","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-ip1012-b510-fieldbus-box-8-channel-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}