{"product_id":"beckhoff-ip2041-b800-fieldbus-box-8-channel-digital-output-module","title":"IP2041-B800 | Beckhoff | Boîtier de bus de terrain","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eExecuting distributed digital actuation tasks within RS485-based industrial architectures is the primary role of the \u003cstrong\u003eBeckhoff IP2041-B800\u003c\/strong\u003e fieldbus extension module. This dust-tight and water-resistant \u003cstrong\u003eFieldbus Box\u003c\/strong\u003e provides direct, localized control of up to eight high-current actuators without requiring a dedicated control cabinet. By utilizing robust M8 connectors and an IP67-rated enclosure, the device excels in decentralized machine topologies where space, wiring complexity, and exposure to environmental elements are critical engineering considerations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Current Actuation:\u003c\/strong\u003e Provides 8 digital output channels capable of switching up to 2 A per channel.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSerial Integration:\u003c\/strong\u003e Direct connection to host controllers via an RS485 communication interface.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine-Mount Architecture:\u003c\/strong\u003e IP67 environmental protection rating eliminates the need for terminal boxes and protective enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Connectivity:\u003c\/strong\u003e Heavy-duty M8 screw connectors secure I\/O signal lines against severe mechanical vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Configured to handle a cumulative current load of up to 12 A across all active channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDecentralized pneumatic valve manifold actuation on manufacturing lines.\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty conveyor routing and material handling systems.\u003c\/li\u003e\n  \u003cli\u003eFood processing and packaging machinery requiring frequent washdown cycles.\u003c\/li\u003e\n  \u003cli\u003eDistributed industrial automation nodes in high-vibration environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left; border: 1px solid #cbd5e0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP2041-B800\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eProduct Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFieldbus Box (Extension Module)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eNumber of Digital Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eNominal Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eMax. Current per Channel\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 A (short-circuit protected)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eMax. Sum Current (Device)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12 A (across all channels)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eCommunication Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRS485\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eConnection Interface (I\/O)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eM8 screw-type connectors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eIngress Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP67\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-25 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #cbd5e0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhile each channel supports up to 2 A, the cumulative electrical budget is rigidly capped at 12 A. Exceeding this combined threshold will trigger internal thermal protection, causing unexpected shutdowns of active outputs. Design engineers must calculate continuous and peak duty-cycle demands for all eight outputs to ensure total load profiles remain safely below the 12 A maximum rating under hot ambient plant floor conditions.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen establishing serial communication over the RS485 line, active physical termination resistors must be placed at the beginning and the end of the bus chain. For environments containing high electrical noise, run communication cables inside shielded conduits and ensure they are routed away from large variable frequency drives (VFDs) and high-voltage motor conductors to avoid electromagnetic interference and transmission packet loss.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and lock out all electrical power sources supplying both control power and actuator load circuits before initiating installation. Do not hot-plug any M8 field cables or supply interfaces. Ensure all unused M8 connectors are sealed with approved protective caps to preserve the IP67 moisture and dust barrier.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 1rem;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePosition and mount the IP2041-B800 module directly onto the machine frame or mounting plate using dual M4 bolts, tightening to secure against operating vibration.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 1rem;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eConnect the RS485 communication line to the module bus input interface, ensuring the locking collars are fully tightened to maintain the IP67 seal.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 1rem;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eInstall the main 24 V DC power supply cabling, checking polarity alignment carefully before connecting the main terminal.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0; margin-right: 1rem;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePlug the M8 load cables from field actuators into their designated digital output ports, securing each collar firmly. Keep unused ports capped.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106462949739,"sku":"IP2041-B800","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2041-b800-h0j3fwriins.png?v=1776244973","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-ip2041-b800-fieldbus-box-8-channel-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}