{"product_id":"beckhoff-ip2042-b518-fieldbus-box-8-channel-digital-output-module","title":"Module de sortie numérique 8 canaux Beckhoff IP2042-B518 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for decentralized control architectures, the Beckhoff IP2042-B518 operates as a high-performance Fieldbus Box distributing 8 digital output channels directly in rugged field environments via a CANopen interface. This robust device allows the direct connection of 24 V DC actuators, such as solenoid valves, contactors, and indicators, without requiring an additional protective terminal enclosure. Featuring integrated T-connector bus interfaces and \u003cstrong\u003eM12 output connections\u003c\/strong\u003e, it offers an exceptionally high output capacity of up to \u003cstrong\u003e2 A per channel\u003c\/strong\u003e (12 A cumulative total), ensuring reliable power distribution in high-load industrial applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Current Output:\u003c\/strong\u003e Employs 8 digital channels handling 2 A each, individually protected against short circuits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated T-Connector:\u003c\/strong\u003e Simplifies network trunk line wiring with a pre-integrated M12 daisy-chain interface.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Network Adaptation:\u003c\/strong\u003e Instantly detects communication speeds from 10 kbaud up to 1 Mbaud on the CANopen network.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmentally Sealed Housing:\u003c\/strong\u003e Standard XXL polyamide casing with IP65, IP66, and IP67 protection ratings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Built-in variable mapping, emergency objects, and Node\/Life Guarding options for reliable network status tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDecentralized packaging machine lines requiring direct, cabinet-free mounting.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly automation with high-density localized actuator clusters.\u003c\/li\u003e\n  \u003cli\u003eHeavy material handling and conveyor automation systems.\u003c\/li\u003e\n  \u003cli\u003ePneumatic valve manifold control and distributed solenoid piloting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Reference\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP2042-B518\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Count\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8 digital outputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNominal Output Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMax. Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 A per channel (short-circuit proof)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eAggregate Output Limit\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMax. 12 A (Ch 0-3: sum 4 A | Ch 4-5: sum 4 A | Ch 6-7: sum 4 A)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFieldbus System\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCANopen (up to 16 Rx \/ 16 Tx PDOs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBaud Rates\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e10 kbaud to 1 Mbaud (automatic auto-detection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eControl Voltage Current Draw\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e45 mA + sensor current load (max 0.5 A)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eControl voltage to fieldbus: 500 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to +55 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-25 to +85 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEnvironmental Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePolyamide PA6\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDevice Dimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e30 mm x 210 mm x 26.5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eConnector \/ Terminal Type\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003ePin Number\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eFunction \/ Signal Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; rowspan=5; font-weight: bold;\"\u003eCANopen Bus Interface (M12)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eShield \/ Functional Earth\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eV+ (Bus Power, optional)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCAN Ground (GND)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCAN High (CAN_H)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCAN Low (CAN_L)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; rowspan=4; font-weight: bold;\"\u003ePower Supply Inlet (M8 Feed)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eControl Voltage +24 V DC (Us)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eLoad Voltage +24 V DC (Up)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGND Us\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGND Up\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eThe IP2042-B518 is fully compatible with standard Beckhoff CANopen structures. It serves as a direct drop-in replacement for equivalent legacy IP2042 modules using the -B510 and -B518 variants. Users upgrading or replacing modules must ensure that the master PLC controller possesses the correct EDS file to support the extended diagnostics and flexible variable mapping capabilities of the -B518 series.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003ePay close attention to internal power budget grouping rules. While individual channels are short-circuit protected and rated for 2 A, physical thermal constraints within the housing limit aggregate current draws. Specifically, channels 0-3 must not exceed a combined total of 4 A; channels 4-5 must not exceed 4 A; and channels 6-7 are restricted to 4 A. Exceeding these thermal grouped limits can cause regional shut-down or local safety tripping.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eTo optimize signaling efficiency on long CANopen network segments, always utilize properly shielded, twisted-pair copper cabling specifically designed for industrial CAN networks. Additionally, a 120-ohm bus termination resistor must be installed on the unused M12 port if this specific module constitutes the physically final node on the CANopen network bus trunk line.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources (control voltage Us and load voltage Up) prior to mechanical installation, cable connection, or hardware service. Failure to de-energize circuits may cause localized arc faults, damage internal solid-state components, and compromise the network interface.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003ePosition the module on a flat mounting surface and align the physical fixing points. Securely mount using two 3.5 mm diameter M3 screws. Do not over-torque.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eConnect the incoming CANopen network feed line to the integrated M12 plug interface, and loop output networks using the integrated M12 socket.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"width: 24px; height: 24px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eAttach the M8 supply cabling, verifying separate wiring paths for the control voltage (Us) and output load voltage (Up). Tighten the lock rings to ensure an IP67 liquid-tight seal.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106453119339,"sku":"IP2042-B518","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2042-b518-0rv1tpifasp.png?v=1776244978","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-ip2042-b518-fieldbus-box-8-channel-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}