{"product_id":"beckhoff-ip2300-b510-fieldbus-box-4-channel-digital-input-4-channel-digital-output","title":"IP2300-B510 | Beckhoff | Boîte de bus de terrain","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo facilitate distributed decentralized I\/O acquisition in harsh industrial environments, the \u003cstrong\u003eBeckhoff IP2300-B510\u003c\/strong\u003e integrates discrete inputs and outputs directly at the machine level via a high-performance \u003cstrong\u003eCANopen\u003c\/strong\u003e fieldbus interface. This compact Fieldbus Box module features \u003cstrong\u003e4 digital inputs\u003c\/strong\u003e with a 3 ms input filter alongside \u003cstrong\u003e4 digital outputs\u003c\/strong\u003e rated for 0.5 A, housing them within an IP67-rated enclosure designed to bypass the need for protective control cabinets. Connection is established using space-saving M8 connector sockets, minimizing cabling overhead and reducing transmission latency in decentralized automation topologies.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDirect integration into CANopen industrial networks via standard D-sub or M12 connection interfaces.\u003c\/li\u003e\n  \u003cli\u003eRobust IP67 housing design, rendering the unit fully resistant to dust, moisture, and high-pressure washdown environments.\u003c\/li\u003e\n  \u003cli\u003eFour integrated 24 V DC digital inputs featuring an integrated 3 ms hardware input filter to suppress signal contact bounce.\u003c\/li\u003e\n  \u003cli\u003eFour short-circuit proof 24 V DC digital outputs capable of delivering up to 0.5 A continuous current per channel.\u003c\/li\u003e\n  \u003cli\u003eDiagnostic LEDs mapping network activity, device operational status, and localized channel diagnostics.\u003c\/li\u003e\n  \u003cli\u003eSimple rotary address switches for rapid node address configuration during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eAutomotive assembly lines and robotic tool-end I\/O processing.\u003c\/li\u003e\n  \u003cli\u003eConveyor networks and packaging machinery requiring decentralized, machine-mount sensor consolidation.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling plants utilizing distributed CANopen topologies.\u003c\/li\u003e\n  \u003cli\u003eMachine tool control lines subject to high coolant, oil, or particulate exposure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eTechnical Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Identifier\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP2300-B510\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFieldbus System\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCANopen\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDigital Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4 channels (24 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Filter Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3.0 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDigital Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4 channels (24 V DC, short-circuit proof)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMax. Output Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.5 A per channel (total current limits apply)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eI\/O Connection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eM8 (diameter 8 mm circular connectors)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 24 V DC;\"\u003e24 V DC (control and load voltage feeds)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eIngress Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP67 (when all slots are mated or capped)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-25 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e220 mm x 110 mm x 60 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eM8 Connector Pin\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eInput Port Assignment\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eOutput Port Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e+24 V DC Sensor Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNot Connected\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNot Connected\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAuxiliary Ground Reference\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGND Sensor Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGND Load Supply\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDigital Input Signal (DI1 to DI4)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDigital Output Signal (DO1 to DO4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IP2300-B510 utilizes standard CANopen communication profiles. While mechanically identical to the IP2300-B310 (PROFIBUS DP) and IP2300-B900 (Ethernet), it requires a dedicated CANopen master or coupler to map PDOs\/SDOs. If migrating from older legacy Beckhoff Fieldbus Box units, verify your network master's ESD (electronic data sheet) configuration files to ensure parameter mappings match the device profile.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen deploying in wet or high-humidity environments, any unused M8 ports must be covered using IP67-rated protective caps. Leaving even a single port exposed compromises the environmental seal of the entire assembly, leading to moisture ingress and localized internal short circuits between the 24 V DC sensor supply line and ground.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEnsure that the CANopen network is terminated with a 120-Ohm resistor at both ends of the physical bus. If the IP2300-B510 is configured as the physical end-of-line node, a dedicated terminating M12 plug must be inserted. Always set the node ID via the address dial switches under the protective screw cap prior to powering on the control logic feed.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources (logic and field power loops) before mounting, cabling, or adjusting the address switches. Ground loops can induce network dropouts and permanently degrade the integrated output transistors.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the IP2300-B510 module directly onto a flat, vibration-resistant machine frame using M4 mounting screws. Connect the chassis ground contact to the machine frame.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSet the designated CANopen node address and communication baud rate using the rotary switches under the front protective cover. Reseal the cover tightly.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eAttach the M8 sensor and actuator cables, ensuring a secure thread lock is achieved on each connector to protect against moisture intrusion.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the incoming CANopen network cable and power lines. Turn on the 24 V DC system logic and perform testing sequences via your PLC's network master.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106495586667,"sku":"IP2300-B510","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2300-b510-kdgg5ojgx1h.png?v=1776244987","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-ip2300-b510-fieldbus-box-4-channel-digital-input-4-channel-digital-output","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}