{"product_id":"beckhoff-kl2692-bus-terminal","title":"BECKHOFF KL2692 Terminal de bus","description":"\u003cp\u003eThe \u003cstrong\u003eKL2692\u003c\/strong\u003e is a multifunctional \u003cstrong\u003eBus Terminal\u003c\/strong\u003e from \u003cstrong\u003eBECKHOFF\u003c\/strong\u003e, combining 2 potential-free relay outputs (normally-open contacts) and 2 digital 24 V DC inputs in a single compact module. This terminal is designed for efficient signal processing and actuator control, allowing for the switching of ohmic or inductive loads up to 5 A (ohmic). With an electrical isolation of 500 V between the K-bus and field potential, the \u003cstrong\u003eKL2692\u003c\/strong\u003e ensures reliable separation in complex automation architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 potential-free relay outputs (normally-open contacts)\u003c\/li\u003e\n\u003cli\u003e2 digital 24 V DC inputs\u003c\/li\u003e\n\u003cli\u003e2-wire connection technology\u003c\/li\u003e\n\u003cli\u003eHigh switching capacity: 5 A ohmic (AC\/DC) per channel\u003c\/li\u003e\n\u003cli\u003eMinimum load capacity of 10 mA at 5 V DC\u003c\/li\u003e\n\u003cli\u003eMechanical service life of 2 x 10^7 operating cycles\u003c\/li\u003e\n\u003cli\u003eConfiguration via Bus Coupler or controller\u003c\/li\u003e\n\u003cli\u003eCompact IP20-rated housing for DIN rail mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed I\/O for relay-based logic control\u003c\/li\u003e\n\u003cli\u003eSwitching of external contactors or solenoids\u003c\/li\u003e\n\u003cli\u003eDigital sensor status acquisition combined with output control\u003c\/li\u003e\n\u003cli\u003eAutomation systems requiring mixed input\/output functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBECKHOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKL2692\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e2 (relay, NO contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e2 (digital 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Switching Current (Ohmic)\u003c\/td\u003e\n\u003ctd\u003e5 A AC\/DC per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Switching Current (Inductive)\u003c\/td\u003e\n\u003ctd\u003e2 A AC\/DC per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (K-bus)\u003c\/td\u003e\n\u003ctd\u003etyp. 165 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V (K-bus\/field potential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 60 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the terminal on a 35 mm DIN rail (EN 60715) and secure it using the integrated locking mechanism.\u003c\/li\u003e\n\u003cli\u003eUtilize the double slot and key connection for secure side-by-side assembly.\u003c\/li\u003e\n\u003cli\u003eEnsure all connections comply with the 2-wire wiring technology requirements.\u003c\/li\u003e\n\u003cli\u003eMaintain the ambient operating temperature between 0 and +55 degC to preserve the operational lifespan of the internal relay contacts.\u003c\/li\u003e\n\u003cli\u003eFollow EMC standards EN 61000-6-2\/EN 61000-6-4 during wiring to prevent signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106598773099,"sku":"KL2692","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl2692-efsm5qxt2m3.png?v=1776245141","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-kl2692-bus-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}