{"product_id":"beckhoff-kl3444-bus-terminal-analog-input-module","title":"Bornier BECKHOFF KL3444 Module d'entrée analogique","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for processing standardized analog current signals, the \u003cstrong\u003eBeckhoff KL3444\u003c\/strong\u003e Bus Terminal processes signals in the 0 to 20 mA range with high-resolution acquisition. This compact, 12 mm wide module features four single-ended input channels, making it optimal for spaced-constrained control cabinets requiring multi-channel density. The device derives its power directly from the internal K-bus system, enabling seamless communication with the master PLC or industrial PC coupler. Utilizing 12-bit digital resolution, the module ensures accurate transmission of system variables to the controller. A robust design featuring 500 V galvanic isolation between the K-bus and the field signal inputs guarantees system stability and protects sensitive control-side electronics from external electrical disturbances.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour single-ended analog input channels operating in the 0 to 20 mA range.\u003c\/li\u003e\n  \u003cli\u003eFast conversion time of approximately 2 ms for real-time monitoring.\u003c\/li\u003e\n  \u003cli\u003eGalvanic isolation of 500 V between the K-bus and the input signal lines.\u003c\/li\u003e\n  \u003cli\u003eCompact KL-12-8pin housing with integrated status LEDs for quick diagnostic checks.\u003c\/li\u003e\n  \u003cli\u003eTool-free mounting on 35 mm DIN rails via double slot-and-key connection.\u003c\/li\u003e\n  \u003cli\u003eSpring-clamp termination for quick, vibration-resistant field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProcess manufacturing and chemical plant signal monitoring.\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater pressure\/flow sensor integration.\u003c\/li\u003e\n  \u003cli\u003eMachine building and factory automation telemetry.\u003c\/li\u003e\n  \u003cli\u003eHVAC control and environmental monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eModel \/ Part Number\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKL3444\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal, 4-channel analog input, current, 0 to 20 mA, 12 bit, single-ended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKS3444\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal, 4-channel analog input, current, 0 to 20 mA, 12 bit, single-ended, pluggable wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eKL3444\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Current\u003c\/td\u003e\n      \u003ctd\u003e0 to 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTechnology\u003c\/td\u003e\n      \u003ctd\u003eSingle-ended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInternal Resistance\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 85 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConversion Time\u003c\/td\u003e\n      \u003ctd\u003e~ 2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e12 bit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasuring Error\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; +\/-0.3% (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSurge Voltage Resistance\u003c\/td\u003e\n      \u003ctd\u003e30 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption K-bus\u003c\/td\u003e\n      \u003ctd\u003etyp. 85 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBit Width in Process Image\u003c\/td\u003e\n      \u003ctd\u003eInput: 4 x 16 bit data (4 x 8 bit control\/status optional)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eapprox. 55 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95%, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Dimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap securely onto a standard 35 mm DIN rail (conforming to EN 60715). Ensure the locking mechanism is engaged.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use solid (0.08 to 2.5 mm²), flexible (0.08 to 2.5 mm²), or ferruled (0.14 to 1.5 mm²) conductors. Push a suitable screwdriver into the spring release to insert the wire.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Route signal lines away from high-power distribution lines. Use shielded cables in high-noise environments to ensure signal integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain standard operating spacing around the module to prevent thermal buildup, ensuring ambient temperature remains below +55 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eATEX: II 3 G Ex nA IIC T4 Gc\u003c\/li\u003e\n  \u003cli\u003eDNV GL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106501943659,"sku":"KL3444","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl3444-fgbkjbvn221.png?v=1776245160","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-kl3444-bus-terminal-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}