{"product_id":"beckhoff-ks3142-bus-terminal","title":"KS3142 | BECKHOFF | Terminal de bus","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eAcquisition of analog sensor signals within automated industrial networks is performed efficiently using the \u003cstrong\u003eBECKHOFF KS3142\u003c\/strong\u003e analog input terminal. This high-precision \u003cstrong\u003eBus Terminal\u003c\/strong\u003e provides dual-channel connection capabilities for field sensors operating with standard 0 to 20 mA signal currents. Utilizing a robust differential input design and a 16-bit analog-to-digital converter, the module delivers highly accurate measurement data directly to the K-bus process image. The distinctive feature of the KS-series housing is its pluggable wiring level, which enables fast assembly and easy replacement of the terminal block without disconnecting the established field-side wire connections.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo-channel analog input module processing 0 to 20 mA field signals.\u003c\/li\u003e\n  \u003cli\u003eHigh-resolution 16-bit analog-to-digital conversion with increased measuring accuracy.\u003c\/li\u003e\n  \u003cli\u003eConfigurable conversion time and integral 50 Hz filter to eliminate signal noise.\u003c\/li\u003e\n  \u003cli\u003ePluggable connection level allows quick terminal swapping during maintenance operations.\u003c\/li\u003e\n  \u003cli\u003eDifferential inputs with 500 V galvanic isolation between the K-bus and field signals.\u003c\/li\u003e\n  \u003cli\u003eIntegrated surge voltage resistance up to 35 V DC for enhanced field protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMachine building and precision assembly equipment\u003c\/li\u003e\n  \u003cli\u003eIndustrial process instrumentation loops\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment facility monitoring\u003c\/li\u003e\n  \u003cli\u003ePower generation and thermodynamic plant controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eKS3142\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVia the K-bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignal Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDifferential input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 100 Ohm shunt\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommon-mode Voltage (UCM)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003emax. +\/-10 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 bit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e140 ms (configurable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFilter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Hz (configurable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasuring Error\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; +\/-0.05% (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSurge Voltage Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption K-bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 85 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBit Width in Process Image\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInput: 2 x 16-bit data (2 x 8-bit control\/status optional)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95%, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation Position\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSpring actuation by screwdriver (pluggable connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Cross-section\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSolid\/stranded: 0.08 to 1.5 mm², Fine-wire: 0.14 to 1.5 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Cross-section AWG\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSolid\/stranded: AWG 28 to 16, Fine-wire: AWG 26 to 16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStripping Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9 to 10 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Load Power Contacts\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eImax: 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.8 cm x 1.2 cm x 10.0 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.07 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap directly onto a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking latch engages securely.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Insert a small screwdriver into the clamp spring release slot to open the connection point, insert the stripped conductor (9 to 10 mm stripping length), and release the spring clamp.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePluggable Block:\u003c\/strong\u003e Ensure the power supply is completely switched off before engaging or disengaging the pluggable terminal wiring block.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Connect analog signal shields to the nearest functional ground bar to prevent environmental electromagnetic interference from affecting signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eATEX\u003c\/li\u003e\n  \u003cli\u003eEx Marking: II 3 G Ex nA IIC T4 Gc\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106490933611,"sku":"KS3142","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ks3142-uzrdpu3i3zi.png?v=1776245292","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-ks3142-bus-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}