{"product_id":"beckhoff-ks4021-bus-terminal-1-channel-analog-output-4-20-ma","title":"BECKHOFF KS4021 Terminal bus de sortie analogique 1 canal 4-20 mA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS4021 (KS4021)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBus Terminal processes analog control signals in the range between 4 and 20 mA with a 12-bit resolution. Designed for harsh industrial environments such as chemical processing, water treatment plants, and power generation facilities, this single-ended analog output module transmits signals with galvanic isolation to the actuator level. Its compact, high-efficiency design directly addresses industrial downtime risks by utilizing pluggable wiring levels, which allow for rapid field replacement without disconnecting individual terminal wires. Operating on the proven Beckhoff K-bus system, the module ensures reliable, real-time data communication back to the central PLC or IPC controller.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe KS4021 features a single-ended circuit topology, optimizing it for space-constrained control cabinets where individual channel routing is required. It receives power directly from the 24 VDC power contacts, though it supports an alternative 15 VDC supply via a KL9515 power supply terminal to accommodate specialized system architectures.\u003c\/p\u003e\n\u003cp\u003eThe process image utilizes 1 x 16-bit data, with an optional 1 x 8-bit control and status byte for advanced diagnostics. It requires zero hardware configuration or address settings, enabling pure plug-and-play integration into the TwinCAT engineering environment. The terminal housing features a double slot and key connection system for robust side-by-side DIN rail mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKS4021\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBECKHOFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-ended\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC via power contacts (alternative 15 VDC with KL9515)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 500 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Error\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than +\/-0.1 % (relative to end value)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 1.5 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 V (K-bus to signal voltage)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption (Power Contacts)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTyp. 30 mA + load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption (K-bus)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTyp. 60 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.8 cm x 1.2 cm x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.08 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 %, no condensation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApprovals \/ Markings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, ATEX, DNVGL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEx Marking\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eII 3 G Ex nA IIC T4 Gc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the practical difference between the KS4021 and the KL4021?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe primary difference lies in the housing design. The KS4021 features a pluggable wiring level, allowing the entire terminal block electronics to be swapped out while leaving the field wiring intact. The KL4021 uses fixed wiring terminals where cables must be individually disconnected during service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle output errors if the load resistance exceeds 500 Ohm?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the total loop resistance exceeds 500 Ohm, the internal digital-to-analog converter will saturate. This prevents the module from driving the full 20 mA current, resulting in an inaccurate output signal and triggering an error status bit in the PLC process image.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this terminal require manual configuration in TwinCAT?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo manual address or parameter configuration is required on the hardware itself. The K-bus automatically detects the module type and position upon system startup, mapping the 16-bit output data directly into the controller configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation and Wiring Instructions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePluggable Terminal Block Operation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo release or insert individual wires, use a standard slot screwdriver to actuate the integrated tension clamp mechanism. Strip all signal wires to exactly 9 to 10 mm. Ensure the connection cross-section matches the specification (AWG 28 to 16 for solid or stranded wires).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Noise Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor industrial environments with high electromagnetic interference (EMI), always use shielded twisted-pair cables for the 4 to 20 mA loop. Ground the cable shield at only one end—ideally at the entry point of the control cabinet—to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eATEX Zone 2 Safety Mandates:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the module in hazardous areas marked II 3 G Ex nA IIC T4 Gc, the terminal must be mounted inside an IP54 rated enclosure conforming to EN 60079-15. Do not disconnect or insert the pluggable wiring levers while the system is energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106631180651,"sku":"KS4021","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ks4021-iabvoohiu5h.png?v=1776245315","url":"https:\/\/www.plcprotech.com\/fr\/products\/beckhoff-ks4021-bus-terminal-1-channel-analog-output-4-20-ma","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}