{"product_id":"bently-nevada-136180-01-3500-92-communication-gateway-module","title":"Module passerelle de communication Bently Nevada 136180-01 3500\/92","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136180-01 3500\/92 Communication Gateway Module\u003c\/strong\u003e provides communication integration between the 3500 machinery protection system and external process control or automation platforms. The module supports both Ethernet TCP\/IP and serial communication interfaces for transferring monitored values, alarm statuses, module statuses, and system data from the 3500 rack.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/92 Communication Gateway Module\u003c\/strong\u003e supports Modicon Modbus protocol through serial communication interfaces including RS232, RS422, and RS485. It also supports Modbus\/TCP communication over Ethernet networks and proprietary Bently Nevada communication protocols for use with 3500 Rack Configuration Software and Data Acquisition Software.\u003c\/p\u003e\n\u003cp\u003eThe module communicates with other rack modules through the internal high-speed 3500 rack network. Collected data may include current measured values with time stamps, module health information, and alarm conditions depending on installed module configuration.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface uses an RJ45 connection designed for 10BASE-T Ethernet networks conforming to IEEE802.3 standards. The module supports configurable Modbus register mapping through the Configurable Modbus Register Utility.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports Ethernet TCP\/IP communication\u003c\/li\u003e\n\u003cli\u003eSupports RS232, RS422, and RS485 serial interfaces\u003c\/li\u003e\n\u003cli\u003eCompatible with Modbus and Modbus\/TCP protocols\u003c\/li\u003e\n\u003cli\u003eSupports proprietary Bently Nevada communication protocol\u003c\/li\u003e\n\u003cli\u003eRJ45 Ethernet connection for 10BASE-T networks\u003c\/li\u003e\n\u003cli\u003eInternal high-speed rack communication\u003c\/li\u003e\n\u003cli\u003eConfigurable Modbus register mapping\u003c\/li\u003e\n\u003cli\u003eCommunication with 3500 Rack Configuration Software\u003c\/li\u003e\n\u003cli\u003eCommunication with 3500 Data Acquisition Software\u003c\/li\u003e\n\u003cli\u003eRack monitored value and status integration\u003c\/li\u003e\n\u003cli\u003eFront-panel OK and TX\/RX status LEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection system integration\u003c\/li\u003e\n\u003cli\u003eTurbine monitoring systems\u003c\/li\u003e\n\u003cli\u003eDistributed control system communication\u003c\/li\u003e\n\u003cli\u003eProcess automation integration\u003c\/li\u003e\n\u003cli\u003ePower generation monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial condition monitoring\u003c\/li\u003e\n\u003cli\u003eData acquisition systems\u003c\/li\u003e\n\u003cli\u003ePlant-wide monitoring networks\u003c\/li\u003e\n\u003cli\u003eSCADA communication systems\u003c\/li\u003e\n\u003cli\u003eVibration monitoring infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003e136180-01: 3500\/92 Communication Gateway Module.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eCategorySpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eCommunication Gateway Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e136180-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e5.0 Watts typical with Modbus RS232\/RS422 I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e5.6 Watts typical with Modbus RS485 I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eData Collection\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eMeasured values, module statuses, alarm statuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eUpdate Time\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eWill not exceed 1 second for all modules in the 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eEthernet Speed\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eEthernet Standard\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eIEEE802.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eEthernet Protocol\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eEthernet TCP\/IP and Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eEthernet Connection\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eRJ-45 for 10BASE-T Ethernet cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eSupported Serial Interfaces\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eRS232, RS422, RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eModbus RTU, Modbus\/TCP, Bently Nevada protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eHumidity\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e241 mm x 24.4 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e0.82 kg (1.8 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003eIndicators\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003eOK LED, TX\/RX LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003eMain Board Dimensions\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e241 mm x 24.4 mm x 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"22\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"22\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eConnector PinFunction\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eRJ45 Port\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eEthernet TCP\/IP communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eRS232 Interface\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eSerial Modbus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eRS422 Interface\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSerial Modbus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eRS485 Interface\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eMulti-drop serial Modbus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eOK LED\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eModule operational status indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eTX\/RX LED\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eCommunication activity indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a compatible 3500 rack slot.\u003c\/li\u003e\n\u003cli\u003eVerify proper rack grounding before energizing the system.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cables for serial interfaces.\u003c\/li\u003e\n\u003cli\u003eSeparate communication wiring from high-voltage power cables.\u003c\/li\u003e\n\u003cli\u003eMaintain proper Ethernet cable routing to reduce EMI interference.\u003c\/li\u003e\n\u003cli\u003eConfirm network configuration before connecting to automation systems.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation inside the rack enclosure.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive humidity or condensation exposure.\u003c\/li\u003e\n\u003cli\u003eTighten communication connectors securely during installation.\u003c\/li\u003e\n\u003cli\u003eUse appropriate communication termination practices for RS485 networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides communication between the 3500 rack and external automation or control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich communication protocols are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports Modbus RTU, Modbus\/TCP, and proprietary Bently Nevada protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support Ethernet communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It supports Ethernet TCP\/IP communication over 10BASE-T networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Ethernet connector type is used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Ethernet connection uses an RJ45 interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich serial communication interfaces are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRS232, RS422, and RS485 interfaces are supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module communicate with SCADA systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It can integrate with SCADA and process control systems using Modbus protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat data can be collected from the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module can collect measured values, module statuses, and alarm statuses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum update time for rack data?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe update time does not exceed 1 second for all rack modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software is compatible with this gateway module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports 3500 Rack Configuration Software and Data Acquisition Software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat LED indicators are available on the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes OK and TX\/RX status LEDs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe operating range is -30 degC to +65 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support Modbus\/TCP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Modbus\/TCP communication is supported through Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan RS485 be used for multi-device communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. RS485 supports multi-drop communication networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat rack system is this module designed for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is designed for the Bently Nevada 3500 machinery protection system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module suitable for industrial monitoring networks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is intended for industrial monitoring and automation integration applications.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861027691,"sku":"3500\/92 136180-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-92-136180-01-communication-gateway-modules-jg544a3ztna_9bc14a04-52ec-426d-90af-06d1189ef262.jpg?v=1765449298","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-136180-01-3500-92-communication-gateway-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}