{"product_id":"bently-nevada-136711-02-3500-61-rtd-tc-i-o-module","title":"Bently Nevada 136711-02 3500\/61 Module E\/S RTD\/TC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 136711-02\u003c\/strong\u003e is a specialized \u003cstrong\u003eRTD\/TC I\/O Module with Internal Barriers and Internal Terminations\u003c\/strong\u003e developed for the \u003cstrong\u003e3500\/61 16-Channel Temperature Monitor\u003c\/strong\u003e within the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. This hardware component serves as the physical interface layer that collects multi-channel temperature signals from field-located transducers. This specific non-isolated variant is engineered with integrated safety barriers, allowing users to configure the termination paths to accept either thermocouple (TC) or resistance temperature detector (RTD) inputs, as well as a flexible combination of both sensor categories simultaneously within the same rack subsystem.\u003c\/p\u003e\n\u003cp\u003eField programming and configuration of channel types are handled through the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e, removing any requirements for physical hardware modifications or field calibration procedures. The module conditions the raw millivolt signals from thermocouples and resistance variances from 3-wire or 4-wire RTDs, feeding structured digital temperature values directly into the main front processor card via the internal backplane bus. Its onboard intrinsic safety design provides a high degree of integration by combining terminal blocks and hazardous area containment barriers into a single space-saving footprint, making the \u003cstrong\u003e3500\/61\u003c\/strong\u003e subsystem ideal for multi-point thermal surveillance of bearings, stator windings, and exhaust paths on heavy rotating assets.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHouses physical internal termination blocks paired with integrated safety barriers for hazardous field environments.\u003c\/li\u003e\n\u003cli\u003eNon-isolated universal channel paths support individual configuration for TCs, 3-wire RTDs, or 4-wire RTDs.\u003c\/li\u003e\n\u003cli\u003eEliminates the need for manual component calibration through full integration with the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes dedicated high-precision current source networks to satisfy multi-lead RTD measuring circuits.\u003c\/li\u003e\n\u003cli\u003eStructural design optimizes rack footprint by consolidating external terminal boxes and separate intrinsic safety hardware into one rear slot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-channel motor and generator stator winding thermal monitoring.\u003c\/li\u003e\n\u003cli\u003eGas turbine exhaust gas temperature (EGT) profile tracking and distribution mapping.\u003c\/li\u003e\n\u003cli\u003eIndustrial bearing temperature monitoring on high-speed pumps, fans, and gearboxes.\u003c\/li\u003e\n\u003cli\u003eBalance-of-plant auxiliary machinery protection across chemical and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e136711-02: RTD\/TC I\/O Module with Internal Barriers and Internal Terminations (Non-Isolated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical \u0026amp; Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Subtype\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated with Internal Safety Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Current Source Value\u003c\/td\u003e\n\u003ctd\u003e925 +\/- 15 uA at 25 degC per transducer (1 supply for 4-wire RTD, 2 supplies for 3-wire RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer \u0026amp; Sensor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple (TC) Capability\u003c\/td\u003e\n\u003ctd\u003eType E, Type J, Type K, Type T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Temperature Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eType E: -100 degC to +1000 degC (-148 degF to +1832 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType J: -18 degC to +760 degC (+0 degF to +1400 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType K: -18 degC to +1370 degC (+0 degF to +2498 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eType T: -160 degC to +400 degC (-256 degF to +752 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Temperature Detector (RTD)\u003c\/td\u003e\n\u003ctd\u003e100 Ohm platinum (alpha = 0.00385), 100 Ohm platinum (alpha = 0.00392), 120 Ohm nickel, 10 Ohm copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Measurement Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm platinum (0.00385): -200 degC to +850 degC (-328 degF to +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e100 Ohm platinum (0.00392): -200 degC to +700 degC (-328 degF to +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e120 Ohm nickel: -80 degC to +260 degC (-112 degF to +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e10 Ohm copper: -100 degC to +260 degC (-148 degF to +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges with External Barriers\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Ohm platinum (0.00385): -50 degC to +850 degC (-122 degF to +1562 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e100 Ohm platinum (0.00392): -50 degC to +260 degC (-122 degF to +1292 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e120 Ohm nickel: -50 degC to +260 degC (-122 degF to +500 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e10 Ohm copper: -50 degC to +260 degC (-122 degF to +500 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Conditioning \u0026amp; Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF (except for 10 Ohm Copper RTDs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Isolated External Termination Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBulkhead Rack: +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eStandard Rack: +\/-1 degC at 25 degC (+\/-1.8 degF at 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolated Internal Termination Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBulkhead Rack: +\/-2 degC at 25 degC (+\/-3.6 degF at 77 degF) \/ +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eStandard Rack: +\/-3 degC at 25 degC (+\/-5.4 degF at 77 degF)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eNo field calibration required; specified at +25 degC (+77 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (32 degF to +150 degF) when used with Internal Barrier modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Dimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Position Requirements\u003c\/td\u003e\n\u003ctd\u003eConsumes 1 full-height rear slot directly behind the main monitor processor card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Barrier Screw Terminals\u003c\/td\u003e\n\u003ctd\u003eDirect physical land connection for raw multi-wire RTD leads and TC field extensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Backplane Bus Plug\u003c\/td\u003e\n\u003ctd\u003eMulti-pin interconnect matrix delivering conditioned sensor data to the 3500 rack bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment:\u003c\/strong\u003e Install the \u003cstrong\u003e136711-02\u003c\/strong\u003e module directly from the rear side of the 3500 monitoring chassis. It must align perfectly into the slot corresponding to the front-mounted 3500\/61 main processor card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Type Matching:\u003c\/strong\u003e Verify through configuration utility software that each channel configuration (thermocouple versus 3-wire or 4-wire RTD) exactly matches the field wire layout connected to the terminal strip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Wire Uniformity:\u003c\/strong\u003e For all 3-wire and 4-wire RTD configurations, employ copper lead wires of uniform gauge and length to guarantee precise lead-resistance compensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Control:\u003c\/strong\u003e Run all external field sensor lines through twisted, shielded wire pairs. Land the shields at the designated instrumentation ground terminal provided on the module frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Enforcement:\u003c\/strong\u003e Ensure the cabinet installation maintains clean, unobstructed ventilation paths so that the active operating ambient temperature around the internal barrier housing does not exceed 65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 136711-02 component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as the rear terminal and intrinsic safety interface module that routes field RTD and thermocouple signals into a 3500\/61 monitor slot.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the designation non-isolated mean for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt indicates that the channels share a common ground reference point, although they remain protected via built-in internal safety barriers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix thermocouples and RTDs on the same I\/O card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the non-isolated channel paths can be customized individually via software to accept a mixed combination of TCs and RTDs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific type of RTD is recommended for standard engineering installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlatinum RTDs featuring an alpha value of 0.00385 are the industrial standard and are highly recommended for optimal precision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs manual field calibration required after replacing this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo manual field calibration is needed because all channel parameter scaling is managed automatically through system configuration software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat constant current value is provided for RTD sensors by this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated current source network delivers 925 +\/- 15 uA at an environmental reference of 25 degC per transducer pathway.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many internal current supplies are engaged when a 4-wire RTD is connected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module configuration activates a single current supply line for a 4-wire RTD circuit and two separate supplies for a 3-wire RTD circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the defined operating temperature limitation for this module version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is specified to perform reliably in a continuous ambient temperature environment ranging from 0 degC to +65 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the exact physical dimensions of this rear-mount component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe card measures 241.3 mm in height, 24.4 mm in width, and 163.1 mm in depth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this component contain the primary digital processor card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this part number represents the rear-insert I\/O termination assembly with built-in barriers; the front processor module is supplied separately.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520273259,"sku":"3500\/61 136711-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-136711-02-temperature-module-cnm5uk4ps0a_ea8ec829-abb6-47bf-af49-d0ad661bbb09.jpg?v=1765440149","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-136711-02-3500-61-rtd-tc-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}