{"product_id":"bently-nevada-176449-08-3500-72m-recip-rod-position-monitor","title":"Moniteur de position de tige réciproque Bently Nevada 176449-08 3500\/72M","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e176449-08 3500\/72M Recip Rod Position Monitor\u003c\/strong\u003e is a four-channel reciprocating compressor monitoring module designed for continuous rod position, rod drop, and hyper-compressor measurement inside the Bently Nevada 3500 machinery protection platform. The monitor accepts up to four proximity transducer inputs and conditions the signals for dynamic displacement, gap voltage, crank angle, and vector amplitude analysis. The module supports API 618 reciprocating compressor applications in refineries, gas processing stations, LNG plants, and petrochemical facilities where early detection of piston rod wear, rider band degradation, and crosshead movement is critical for reducing unplanned shutdowns and compressor damage.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/72M architecture uses four independent monitoring channels grouped in programmable channel pairs. Each pair can perform separate rod position or rod drop functions simultaneously within the same rack slot. The monitor communicates with other rack modules through the 3500 backplane communication system and supports user-configurable alert and danger alarm logic through the 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003cp\u003eSignal conditioning includes fixed peak-to-peak filtering, constant Q notch filtering, 1X and 2X vector analysis, and gap voltage processing for reciprocating compressor diagnostics. Buffered transducer outputs on the front panel provide direct access to dynamic vibration and gap voltage signals for portable analyzers and oscilloscope measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe module supports the following measurement modes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRod Position\u003c\/li\u003e\n\u003cli\u003eRod Drop\u003c\/li\u003e\n\u003cli\u003eHyper Compressor\u003c\/li\u003e\n\u003cli\u003eAverage Piston Position\u003c\/li\u003e\n\u003cli\u003eInstantaneous Probe Gap\u003c\/li\u003e\n\u003cli\u003e1X and 2X Vector Amplitude\u003c\/li\u003e\n\u003cli\u003eCrank Angle Tracking\u003c\/li\u003e\n\u003cli\u003eNot 1X Amplitude Analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eParameter Specification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e176449-08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e3500\/72M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eRecip Rod Position Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eMonitoring Channels\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSupported Inputs\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e1 to 4 proximity probe signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e7.7 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eBuffered Output Impedance\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e510 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eTransducer Supply Voltage\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eFront Panel Indicators\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eOK, TX\/RX, Bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e1 Hz to 600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eGap Filter Response\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-3 dB at 0.09 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e1X and 2X Speed Range\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e60 cpm to 2130 cpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003ePeak-Peak Accuracy\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e+\/-0.33% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003eMaximum Measurement Error\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e+\/-1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003eRod Position Angle Accuracy\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e+\/-1 degree typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003eMaximum Angle Error\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e+\/-3 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e241.3 mm x 24.4 mm x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"22\"\u003eRack Platform\u003c\/td\u003e\n\u003ctd data-row=\"22\"\u003e3500 Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"23\"\u003eApplication Standard\u003c\/td\u003e\n\u003ctd data-row=\"23\"\u003eAPI 618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"24\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"24\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e3500\/72M Recip Rod Position Monitor Guide\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/72M Reciprocating Rod Position Monitor is a 4-channel module designed for reciprocating compressors. It measures rod drop, rod position, and hyper-compressor plunger position. The \u003ccode\u003e-08\u003c\/code\u003e option specifically denotes the \u003cstrong\u003e4-channel Recip Rod Position Monitor with I\/O Module with Internal Terminations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e🛠️ Section 1: Detailed Installation Guide\u003c\/h4\u003e\n\u003ch5\u003e1. Pre-Installation Checklist\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Off\u003c\/strong\u003e: Turn off all rack power before inserting or removing modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection\u003c\/strong\u003e: Wear a grounded wrist strap to prevent electrostatic discharge damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Compatibility\u003c\/strong\u003e: The 3500\/72M main module must be installed in any monitoring slot (slots 2 through 15).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Matching\u003c\/strong\u003e: The I\/O module must be installed directly behind the main module in the rear of the rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e2. Hardware Installation Steps\u003c\/h5\u003e\n\u003cpre data-language=\"plain\"\u003e[Front of Rack]                        [Rear of Rack]\n+--------------------------+           +--------------------------+\n\n|  3500\/72M Main Module    |  \u0026lt;=====\u0026gt;  |  176449-08 I\/O Module    |\n+--------------------------+           +--------------------------+\n\u003c\/pre\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocate Slot\u003c\/strong\u003e: Choose an available slot in the 3500 rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Rear I\/O\u003c\/strong\u003e: Align the 176449-08 I\/O module with the chassis guides at the back of the rack. Slide it in until the connectors engage completely. Tighten the thumb screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Main Module\u003c\/strong\u003e: Align the 3500\/72M main module with the front chassis guides. Slide it in firmly until it seats into the backplane. Tighten the thumb screws.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch5\u003e3. Field Wiring (Internal Terminations)\u003c\/h5\u003e\n\u003cp\u003eThe 176449-08 uses internal termination blocks. Connect the Proximitor sensor wires directly to the Euro-style terminal strips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Wiring for Each Channel (Ch 1 to Ch 4):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVT (Voltage)\u003c\/strong\u003e: Connect to the Proximitor \"VT\" or Pin A (Signal Out).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOM (Common)\u003c\/strong\u003e: Connect to the Proximitor \"COM\" or Pin B (System Common).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-24V (Power)\u003c\/strong\u003e: Connect to the Proximitor \"-24V\" or Pin C (Power Input).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSHLD (Shield)\u003c\/strong\u003e: Connect the cable shield here. Terminate the shield \u003cem\u003eonly\u003c\/em\u003e at the monitor end.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e4. Software Configuration (3500 Rack Configuration Software)\u003c\/h5\u003e\n\u003col\u003e\n\u003cli\u003eOpen the \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eAdd the \u003cstrong\u003e3500\/72M\u003c\/strong\u003e to the slot where it was physically installed.\u003c\/li\u003e\n\u003cli\u003eSelect the \u003cstrong\u003eRecip Rod Position\u003c\/strong\u003e channel type.\u003c\/li\u003e\n\u003cli\u003eConfigure the \u003cstrong\u003eProbe Orientation\u003c\/strong\u003e (typically vertical or orthogonal angles relative to the rod orientation).\u003c\/li\u003e\n\u003cli\u003eEnter the \u003cstrong\u003eScale Factor\u003c\/strong\u003e (typically 7.87 V\/mm or 200 mV\/mil for standard Proximitor systems).\u003c\/li\u003e\n\u003cli\u003eSet \u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e (Alert and Danger limits) according to the OEM specifications of your compressor.\u003c\/li\u003e\n\u003cli\u003eDownload the configuration to the rack via the 3500\/22M Transient Data Interface (TDI).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003e❓ Section 2: Frequently Asked Questions (FAQ)\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does the \"-08\" suffix stand for in part number 176449-08?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: It specifies the \u003cstrong\u003e4-channel Recip Rod Position Monitor with an I\/O Module featuring Internal Terminations\u003c\/strong\u003e. This means field wiring connects directly to the screw terminals on the back of the I\/O module without requiring an external termination block.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I hot-swap the 3500\/72M module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: \u003cstrong\u003eYes\u003c\/strong\u003e, the 3500 system supports hot-swapping (\"Hot Insertion\") of main monitoring modules. However, you must be extremely careful not to short out any adjacent pins, and changing the rear I\/O module requires completely powering down the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why is a Multi-Event Wheel (or Crankcase Keyphasor) needed for this monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Reciprocating rod position measurements require knowing the exact position of the piston within its stroke cycle. The 3500\/72M uses the Keyphasor signal to trigger measurement windows at specific crank angles (e.g., Top Dead Center or Bottom Dead Center).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What are the LED statuses on the front panel indicating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOK LED\u003c\/strong\u003e: Green means the module is functioning correctly. Flashing means it is initializing or in configuration mode. Off means a hardware fault or lack of power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTX\/RX LED\u003c\/strong\u003e: Flashing amber indicates active communication with the 3500\/22M TDI module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBypass LED\u003c\/strong\u003e: Solid amber indicates that one or more channels are currently bypassed (alarms suppressed).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How do I handle rod drop measurements vs. standard radial vibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Rod drop measures the average physical position shift of the piston rod due to rider ring wear. Standard vibration filters out the DC component. The 3500\/72M processes the DC voltage change relative to the calibrated reference point to determine rider ring thickness wear.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520535403,"sku":"3500\/72M 176449-08","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-72m-176449-08-recip-rod-position-monitor-ixnkabghioe_34baeb22-d024-4556-8211-15f663eddd28.jpg?v=1765440153","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-176449-08-3500-72m-recip-rod-position-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}