{"product_id":"bently-nevada-330101-00-12-10-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-12-10-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for highly accurate, non-contact shaft position and vibration measurements, the \u003cstrong\u003eBently Nevada 330101-00-12-10-02-05\u003c\/strong\u003e is a high-performance \u003cstrong\u003e3300 XL 8 mm Proximity Probe\u003c\/strong\u003e designed for use within demanding industrial machinery protection systems. It operates on the eddy-current principle to continuously track dynamic displacement, enabling plant operators to detect micro-level rotor vibration and position deviations on critical turbomachinery before mechanical wear or catastrophic failure occurs.\u003c\/p\u003e\n\n\u003cp\u003eThis specific configuration is uniquely defined by its mechanical dimensions and approvals. With an unthreaded case option of 0.0 inches (0 mm) and a compact 1.2-inch (30 mm) overall case length, this probe is tailored for close-coupled bearings and low-clearance housings where a standard longer probe body would interfere. It comes equipped with a 1.0-meter (3.3 feet) standard coaxial cable terminated with a miniature coaxial ClickLoc connector (without connector protector), and is certified under standard hazardous area approvals (CSA, ATEX, IECEx) to ensure seamless and safe integration into explosive or volatile industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRugged 8 mm tip diameter proximity probe optimized for reliable eddy-current displacement measurements.\u003c\/li\u003e\n  \u003cli\u003eFeatures polyphenylene sulfide (PPS) tip material and AISI 303\/304 stainless steel casing for superior robustness in high-vibration and corrosive machinery environments.\u003c\/li\u003e\n  \u003cli\u003eFlush-mount profile featuring 0.0 inches of unthreaded length and a short 1.2-inch overall case length for compact mounting applications.\u003c\/li\u003e\n  \u003cli\u003eStandard 1.0-meter (3.3 feet) triaxial cable insulated with fluoroethylene propylene (FEP) to resist high-temperature chemical exposure.\u003c\/li\u003e\n  \u003cli\u003eSupplied with a secure miniature coaxial ClickLoc connector for quick, click-to-lock connection stability.\u003c\/li\u003e\n  \u003cli\u003eFully certified under standard international agency approvals (CSA, ATEX, IECEx) for installation in Class I, Division 1, and Zone 0 hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous radial vibration and axial position monitoring in high-speed steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eRotor thrust and displacement tracking in heavy industrial centrifugal compressors and pumps.\u003c\/li\u003e\n  \u003cli\u003eBearing oil film thickness and shaft orbit analysis on large electric motor or generator bearings.\u003c\/li\u003e\n  \u003cli\u003eCritical rotating machinery protection within oil and gas refineries, petrochemical plants, and power generation facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eSelected Option Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-12-10-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e12\u003c\/td\u003e\n      \u003ctd\u003e1.2 in (30 mm) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ SKU\u003c\/td\u003e\n      \u003ctd\u003e330101-00-12-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Type\u003c\/td\u003e\n      \u003ctd\u003eNon-contact dynamic displacement, vibration, and position\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Principle\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), begins at approx. 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) plus\/minus 5% under standard conditions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Probe DC Resistance (R_probe)\u003c\/td\u003e\n      \u003ctd\u003e7.59 plus\/minus 0.50 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Resistance\u003c\/td\u003e\n      \u003ctd\u003e50 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Requirements\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc (at 12 mA maximum current consumption)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Installation Torque\u003c\/td\u003e\n      \u003ctd\u003eRecommended: 7.5 N-m (66 in-lbf), Maximum rated: 22.6 N-m (200 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Maximum Rated)\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) probe case to lead; 270 N (60 lbf) at lead to extension cable connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 to +177 Celsius (-62 to +350 Fahrenheit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity Limits\u003c\/td\u003e\n      \u003ctd\u003eLess than 3% change in Average Scale Factor after 56 days at 93% relative humidity (per IEC 68-2-3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe probe utilizes a dedicated coaxial connector interface designed to maintain low loss, low noise transmission in industrial turbine environments:\u003c\/p\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Element\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Connection\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\/beryllium copper ClickLoc coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCenter Conductor\u003c\/td\u003e\n      \u003ctd\u003eCarries high-frequency RF signal from the Proximitor sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Conductor\u003c\/td\u003e\n      \u003ctd\u003eServes as return signal path and system electrical shield\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAlways gap the probe per system calibration, typically to a value of -9 Vdc or approximately 1.27 mm (50 mils) against an AISI 4140 steel target.\u003c\/li\u003e\n  \u003cli\u003eEnsure that field wiring and the coaxial cables are routed through dedicated conduit and kept clear of high-voltage or power transmission lines.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the recommended installation torque of 7.5 N-m (66 in-lbf) during case mounting to prevent thread damage or binding within the bracket.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum bend radius of 25.4 mm (1.0 in) along all parts of the FEP cable run to secure electrical integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA\/US\/C:\u003c\/strong\u003e Class I, Zone 0, AEx ia IIC; Class I, Div 1, Groups A, B, C, D (when installed with appropriate barriers)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e II 1 G Ex ia IIC T1...T5 Ga\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Electromagnetic Compatibility Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865123691,"sku":"330101-00-12-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-12-10-02-05-proximity-probes-veg43sfdqet_97994c7d-ad1e-4657-9df3-077ef3b5c013.jpg?v=1765449415","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330101-00-12-10-02-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}