{"product_id":"bently-nevada-330101-00-20-10-11-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-20-10-11-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330101-00-20-10-11-00\u003c\/strong\u003e represents a Bently Nevada 3300 XL \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e configuration featuring a fully threaded 3\/8-24 UNF case with 0.0 in unthreaded length (Option 00) and a 2.0 in overall case length (Option 20). Built with a 1.0-meter total cable length (Option 10), this specific configuration incorporates a miniature coaxial ClickLoc connector with an integrated connector protector and FluidLoc cable (Option 11), requiring no agency approvals (Option 00) for general-purpose installations.\u003c\/p\u003e\n\n\u003cp\u003eCompared to standard configurations using open connectors and standard cable designs, this variant includes the FluidLoc cable (Option 11) to block oil or other process fluids from migrating through the cable interior in pressurized applications. The fluorosilicone connector protector provides a robust seal over the ClickLoc coaxial connection, shielding it from moisture, contaminants, and mechanical friction. This unarmored probe operates on eddy-current principles to measure displacement, interfacing with a 3300 XL Proximitor sensor and extension cable in critical machinery protection loops.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluidLoc Cable (Option 11):\u003c\/strong\u003e Seals the inner core of the coaxial cable to prevent lubricating oil or process gas migration along the cable path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Connector Protector:\u003c\/strong\u003e Pre-installed fluorosilicone sleeve shields the ClickLoc connection from environmental ingress and abrasion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Threaded Body:\u003c\/strong\u003e 3\/8-24 UNF threaded case with 0.0 in unthreaded length (Option 00) and 2.0 in total case length (Option 20) for versatile threading depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1.0-Meter Total Cable Length:\u003c\/strong\u003e Option 10 matches standard short-routing setups to reach nearby extension cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolyphenylene Sulfide (PPS) Tip:\u003c\/strong\u003e Durable probe tip material designed to withstand aggressive chemical exposures and extreme temperatures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless Steel Case:\u003c\/strong\u003e AISI 303 or 304 stainless steel construction provides high mechanical strength and corrosion resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbine Vibration Monitoring:\u003c\/strong\u003e Shaft vibration and axial position monitoring on high-speed steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressurized Bearings:\u003c\/strong\u003e Displacement measurements on centrifugal compressor or pump rotor shafts where oil seal containment is essential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral-Purpose Machine Protection:\u003c\/strong\u003e Continuous machinery condition monitoring in non-hazardous industrial areas where approvals are not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption \/ Segment\u003c\/th\u003e\n\u003cth\u003eCode Value\u003c\/th\u003e\n\u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330101-00-20-10-11-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0.0 in (fully threaded case)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e2.0 in (20 increments of 0.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required (general-purpose environments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification Parameter\u003c\/th\u003e\n\u003cth\u003eValue \/ Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330101-00-20-10-11-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisplacement (proximity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEddy current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Thread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ohm triaxial, FEP insulated, FluidLoc style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Outer Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.94 mm maximum (for FluidLoc cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with pre-installed protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Protector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluorosilicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.59 Ohm +\/- 0.50 Ohm (center conductor to outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength (Maximum Rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lbf) probe case to probe lead; 270 N (60 lbf) probe lead to extension cable connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Setting:\u003c\/strong\u003e Install the probe with the appropriate physical gap relative to the target shaft (typically 1.27 mm or 50 mils) to achieve proper calibration within the linear range of the 3300 XL Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Handling:\u003c\/strong\u003e Hand-tighten the miniature coaxial ClickLoc connector prior to installing the protective fluorosilicone sleeve. Do not use excessive force or tools on the connector threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Observe the minimum cable bend radius of 25.4 mm (1.0 in) to prevent internal damage or changes in coaxial capacitance. Use proper conduit or mounting clamps to secure the cable and prevent whipping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Ensure the system shield is properly grounded at a single point, typically the monitor rack, and that the probe body is isolated from electrical noise source loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666769441131,"sku":"330101-00-20-10-11-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-20-10-11-00-3300-xl-8-mm-probe-jbkbka0jnkm_a6637161-ccd4-479a-98fc-1770286c12ef.jpg?v=1765447261","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330101-00-20-10-11-00-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}