{"product_id":"bently-nevada-330103-10-12-05-11-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-10-12-05-11-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 10 (100 mm unthreaded length), Option 12 (120 mm case length), and Option 11 (ClickLoc connector with connector protector, FluidLoc cable) specify this 3300 XL 8 mm proximity probe configuration — \u003cstrong\u003e330103-10-12-05-11-05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis metric-threaded transducer lacks outer protective armor, facilitating direct installation into threaded M10 x 1 ports. Operating with a 0.5-meter total cable length (Option 05) and carrying CSA, ATEX, and IECEx approvals (Option 05), it integrates directly with 3300 XL series Proximitor sensors. The integrated FluidLoc cable (Option 11) prevents process liquids or lubrication oils from migrating through the internal coaxial spaces, addressing sealing requirements in pressurized turbine housings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMetric M10 x 1 Thread:\u003c\/strong\u003e Threaded case constructed from AISI 303 or 304 stainless steel without outer protective armor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100 mm Unthreaded Length:\u003c\/strong\u003e Specified by Option 10, providing a 100 mm unthreaded portion of the 120 mm total case length.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFluidLoc Cable (Option 11):\u003c\/strong\u003e Includes a specialized cable design that blocks lubricating oil and other process fluids from migrating through the internal coaxial cable structure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Connector with Protector:\u003c\/strong\u003e Equipped with a miniature gold coaxial ClickLoc connector and a pre-installed connector protector for mechanical and environmental defense.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e0.5 Meter Total Length (Option 05):\u003c\/strong\u003e Total probe cable length of 0.5 meters (1.6 feet) optimized for standard system configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (Option 05):\u003c\/strong\u003e Standard safety approvals covering CSA, ATEX, and IECEx installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachinery Lubrication Systems:\u003c\/strong\u003e Used in installations where the probe must pass through an environment flooded with pressurized turbine lube oil, where oil migration along standard cables could bypass seals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRadial Vibration and Axial Position:\u003c\/strong\u003e Used for shaft radial vibration, axial thrust position, and speed measurements on rotating machinery.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Turbo-machinery:\u003c\/strong\u003e Installed in steam turbines, gas turbines, centrifugal compressors, reciprocating compressors, gearboxes, pumps, and generators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from Technical Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-10-12-05-11-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe, M10 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e100 mm unthreaded length (in 10 mm increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12\u003c\/td\u003e\n      \u003ctd\u003e120 mm overall case length (in 10 mm increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (1.6 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330103-10-12-05-11-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003eMetric M10 x 1, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e100 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Length\u003c\/td\u003e\n      \u003ctd\u003e120 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Length\u003c\/td\u003e\n      \u003ctd\u003e0.5 m (1.6 ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc coaxial cable (Option 11)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eGold-plated miniature coaxial ClickLoc connector with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAgency Approval\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx approvals (Option 05)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTarget Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel (standard calibration target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or AISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at approximately 0.25 mm (10 mils) from the tip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eScale Factor\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal when combined with 3300 XL Proximitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePressure Seal Rating\u003c\/td\u003e\n      \u003ctd\u003eSealed up to 7.0 bar (100 psi) differential between tip and case (Viton O-ring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) case to lead maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Torque\u003c\/td\u003e\n      \u003ctd\u003e7.5 N-m (66 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Case Torque\u003c\/td\u003e\n      \u003ctd\u003e22.6 N-m (200 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e120 mm x 10 mm x 10 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.12 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCoaxial Connector\u003c\/td\u003e\n      \u003ctd\u003eGold-plated miniature coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Protection\u003c\/td\u003e\n      \u003ctd\u003ePre-installed female connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInterchangeability\u003c\/td\u003e\n      \u003ctd\u003eFully compatible with 3300 XL 8 mm extension cables\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement Limit:\u003c\/strong\u003e The maximum length of thread engagement for M10 x 1 threads is 15 mm. Avoid exceeding this to prevent binding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGapping:\u003c\/strong\u003e Set the probe gap within the linear range (typically 1.0 mm or 50 mils offset, corresponding to approximately -9.0 VDC output).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Ensure the probe cable maintains a minimum bend radius of 25.4 mm (1.0 in) during installation to prevent signal attenuation or cable damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCase Torque:\u003c\/strong\u003e Tighten the case to the recommended torque of 7.5 N-m (66 in-lbf). Do not exceed the absolute limit of 22.6 N-m (200 in-lbf) to avoid threading damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Class I, Zone 0\/1\/2, Groups A, B, C, D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e II 1 G Ex ia IIC T4\/T5 Ga\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e Ex ia IIC T4\/T5 Ga\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Fully compliant with environmental standards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666736214379,"sku":"330103-10-12-05-11-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-10-12-05-11-05-3300-xl-8-mm-proximity-probes-edo1ogqahla_81e56c1c-49b4-41dd-9acc-ff7f0ab11705.jpg?v=1765446795","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330103-10-12-05-11-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}