{"product_id":"bently-nevada-330103-10-18-50-01-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-10-18-50-01-00 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330103-10-18-50-01-00\u003c\/strong\u003e specifies a metric thread, unarmored 3300 XL 8 mm proximity probe used as part of Bently Nevada non-contacting eddy-current transducer systems. This configuration features an M10 x 1 thread with a 100 mm unthreaded length (Option 10) and a 180 mm overall case length (Option 18). It is equipped with a 5.0-meter (16.4 feet) total length cable (Option 50), terminated in a miniature coaxial ClickLoc connector with a connector protector (Option 01). No hazardous area agency approvals are selected (Option 00) for this unit.\u003c\/p\u003e\n\u003cp\u003eThe 5.0-meter probe pairs with a 5.0-meter total length 3300 XL Proximitor sensor, as the cable and probe lengths must match the designated system length for calibrated operation. Since it is constructed without armor, this model is used in installations where cable routing occurs entirely within conduits, protective trays, or internal machinery casings where mechanical abrasion risks are minimized. The M10 x 1 metric thread is used in machinery designs requiring metric standard mounting threads instead of imperial options.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eM10 x 1 Metric Thread\u003c\/strong\u003e: Provides standardized metric mounting interface without armor on the probe lead.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100 mm Unthreaded Case Length\u003c\/strong\u003e: Option 10 provides a 100 mm unthreaded region, allowing adjustable depth insertion inside machinery housings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e180 mm Overall Case Length\u003c\/strong\u003e: Option 18 provides 180 mm of overall threaded case length for deep mounting port penetration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e5.0 Meter Total Length\u003c\/strong\u003e: Option 50 provides a 5.0-meter probe cable, eliminating the need for separate extension cables in short-run layouts when paired with a matching 5-meter Proximitor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Connector with Protector\u003c\/strong\u003e: Option 01 terminates the probe in a miniature coaxial ClickLoc connector pre-fitted with a connector protector to prevent environmental exposure and ingress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnarmored Design\u003c\/strong\u003e: Reduced cable diameter profile allows easier routing through narrow pathways and internal conduits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330103 series proximity probes are used for static and dynamic machinery measurements in heavy industries. Common applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration and shaft position monitoring in steam turbines, gas turbines, and large industrial compressors.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position and casing expansion tracking.\u003c\/li\u003e\n  \u003cli\u003eRotational speed and phase reference (Keyphasor) monitoring.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection systems requiring metric mounting thread integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-10-18-50-01-00\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e100 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e18\u003c\/td\u003e\n      \u003ctd\u003e180 mm overall case length (metric threads)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) total system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo agency approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-10-18-50-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 mm (0.31 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size and Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored standard coaxial cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e180 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePre-installed connector protector included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Cable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm standard coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.73 ohms (typical, center to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), typical (with AISI 4140 steel target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSealing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring pressure seal (tip-to-case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.25 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e180 mm x 180 mm x 45 mm (H x W x D) (coiled packaging)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure correct implementation during mechanical installation by adhering to the following guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify the case thread engagement length does not exceed 15 mm for the M10 x 1 mounting thread to prevent binding.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the maximum tightening torque limit of 12 N-m (110 in-lb) when mounting the probe.\u003c\/li\u003e\n  \u003cli\u003eMaintain a minimum cable bend radius of 25.4 mm (1.0 in) to prevent damage to the inner coaxial conductor.\u003c\/li\u003e\n  \u003cli\u003eGrounding of the outer coaxial shield must be maintained through proper connection to the system ground at the Proximitor sensor end.\u003c\/li\u003e\n  \u003cli\u003eEnsure the probe total length (5.0 m) matches the calibrated length of the Proximitor sensor in the loop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCE Directive\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEMC Directive 2014\/30\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRoHS Directive\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEU Directive 2011\/65\/EU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eChina RoHS\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEFUP 15 years standard in accordance with SJ\/T 11364-2024\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSIL 2 capable (HFT=0) and SIL 3 capable (HFT=1) when configured redundantly\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666543309163,"sku":"330103-10-18-50-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-10-18-50-01-00-proximity-probes-f5faqcpybap_8f6198c8-9292-4cd2-b9c5-5b2d96e4600b.jpg?v=1765440493","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330103-10-18-50-01-00-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}