{"product_id":"bently-nevada-330130-045-00-00-3300-xl-extension-cable","title":"Câble d'extension Bently Nevada 330130-045-00-00 3300 XL","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 16px;\"\u003eThe \u003cstrong\u003eBently Nevada 330130-045-00-00\u003c\/strong\u003e is an industrial-grade \u003cstrong\u003e3300 XL Extension Cable\u003c\/strong\u003e featuring a length of 4.5 metres (14.8 feet) and engineered for critical machinery proximity transducer systems. As a core link within the 3300 XL 8 mm proximity transducer system, this 75 ohm triaxial cable interfaces a non-contacting proximity probe with a 3300 XL Proximitor Sensor to transmit high-precision eddy current signals. The physical assembly utilizes advanced fluoroethylene propylene insulation and is equipped with corrosion-resistant, gold-plated miniature coaxial connections, ensuring exceptional signal propagation and electrical integrity for monitoring static position and dynamic vibration parameters on fluid-film bearing machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 16px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFull System Interchangeability:\u003c\/strong\u003e Supports 100% component interchangeability within the 3300 XL series without requiring dedicated bench calibration or individual matching procedures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePremium Coaxial Interconnects:\u003c\/strong\u003e Fitted with gold-plated brass or gold-plated beryllium copper ClickLoc connectors that achieve a secure mechanical lock with finger-tight torque.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fidelity Shielding:\u003c\/strong\u003e Utilizes a 75 ohm triaxial core design that effectively suppresses radio frequency interference and electromagnetic environmental noise.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Insulation Stability:\u003c\/strong\u003e Constructed with high-performance fluoroethylene propylene (FEP) to preserve precise electrical capacitance across wide thermal fluctuations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Backward Compatibility:\u003c\/strong\u003e Fully interchangeable and physically compatible with older, non-XL 3300 series 5 mm and 8 mm eddy current transducer system components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 16px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTurbomachinery Monitoring:\u003c\/strong\u003e Continuous routing links for radial vibration and axial thrust position loops in steam turbines, gas compressors, and power generators.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase Reference \u0026amp; Speed Inputs:\u003c\/strong\u003e Signal transmission for Keyphasor sensor setups and machine overspeed protection loops under continuous thermal stress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSevere Industrial Contexts:\u003c\/strong\u003e Optimized for standard machine enclosures, junction boxes, and restrictive conduit installations exposed to lubricating oils and moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information Breakdown\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 16px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 8px; color: #1a365d;\"\u003eModel Code Segment\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; color: #1a365d;\"\u003eSelected Option Value\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; color: #1a365d;\"\u003eTechnical Meaning \u0026amp; Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e330130\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBase Model\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3300 XL Extension Cable, 75 ohm triaxial construction\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e-045\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCable Length Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4.5 metres (14.8 feet) physical cable length\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e-00\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eConnector Protector \/ Cable Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStandard cable configuration, no connector protector pre-installed\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003e-00\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAgency Approval Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNo hazardous area agency approvals required\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 16px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 8px; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; color: #1a365d;\"\u003eValue \/ Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCable Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e75 ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNominal Capacitance\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCenter Conductor DC Resistance (RCORE)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.99 plus or minus 0.15 ohms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOuter Conductor DC Resistance (RJACKET)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.30 plus or minus 0.06 ohms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnector Structural Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnector Pull Strength\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e270 N (60 lbf) maximum at probe lead to extension cable interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating and Storage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-51 degC to +177 degC (-60 degF to +351 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRelative Humidity Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eLess than 3% change in Average Scale Factor when tested in 93% humidity up to 56 days\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e25.4 mm (1.0 inch)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eExtension Cable Mass (Typical)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e34 g\/m (0.4 oz\/ft)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.00 kg (4.41 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e240 mm x 180 mm x 45 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px; margin-bottom: 16px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 4px 0 0 0;\"\u003ePrior to executing extension cable replacement or routing modifications, completely de-energize the associated Proximitor Sensor power loop and place all machine trip circuits in bypass mode. Verify the machinery train has come to an absolute thermal and mechanical standstill to avoid unexpected machine shutdowns or severe electrical fault conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 16px; color: #2d3748;\"\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e1\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eConduit Routing and Clearance Verification:\u003c\/strong\u003e Clean the inside of all protective conduits and junction boxes. Carefully feed the unarmored extension cable assembly through, ensuring no contact with sharp metallic burrs or sharp structural angles.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e2\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eEnforcing Bend Radius Parameters:\u003c\/strong\u003e Anchor the cable run at regular intervals along its operational profile. Maintain a continuous bend configuration that strictly respects the minimum 25.4 mm (1.0 inch) bend radius to prevent inner conductor micro-fractures.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e3\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eCoaxial Connector Mechanical Locking:\u003c\/strong\u003e Inspect the gold-plated coaxial ClickLoc contacts for oil residue or moisture contamination. Join the extension cable connector to the proximity probe lead firmly by hand until a clear mechanical \"click\" is felt, confirming absolute thread seat engagement.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; min-height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e4\u003c\/span\u003e\n    \u003cdiv\u003e\n      \u003cstrong\u003eEnvironmental Terminal Protection:\u003c\/strong\u003e Apply the included silicone self-fusing tape wrap over the mechanical connector mating zone. Ensure a multi-layer overlap to completely seal out moisture and airborne particles (avoid tape usage if the joint is entirely submerged in turbine oil).\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861093227,"sku":"330130-045-00-00","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-045-00-00-3300-xl-extension-cable-jwzljoj0cam_420ae983-7f53-436b-a6ab-58e6ae7a287b.jpg?v=1765449300","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330130-045-00-00-3300-xl-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}