{"product_id":"bently-nevada-330130-080-01-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-080-01-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-080-01-CN\u003c\/strong\u003e specifies this 3300 XL standard extension cable configured with an 8.0 m length, armored mechanical protection, and a China-specific NEPSI\/CCC hazardous area certification package.\u003c\/p\u003e\n\u003cp\u003eUnlike standard unarmored configurations, this cable includes a flexible AISI 302 or 304 stainless steel armor with an outer FEP jacket that protects the internal triaxial conductor from mechanical damage and abrasive wear. The 8.0-meter length is typically selected to build a 9.0-meter total system length when combined with a standard 1.0-meter proximity probe, or a 10.0-meter total length system in specialized layouts. The trailing -CN suffix adds official CCC and NEPSI explosion-proof certifications required for hazardous industrial plant operations across China.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8.0 meters (26.2 feet) total cable length option.\u003c\/li\u003e\n\u003cli\u003eArmored protection consisting of flexible stainless steel with an FEP outer jacket.\u003c\/li\u003e\n\u003cli\u003e75 Ohm triaxial construction insulated with fluoroethylene propylene.\u003c\/li\u003e\n\u003cli\u003eClickLoc gold-plated coaxial connectors on both ends.\u003c\/li\u003e\n\u003cli\u003eChina hazardous area approval package (-CN suffix) featuring CCC and NEPSI certifications.\u003c\/li\u003e\n\u003cli\u003eInterchangeable with non-XL 3300 series 5 mm and 8 mm transducer components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eCommon industrial applications for this extension cable include monitoring steam and gas turbine shaft vibration, monitoring compressor axial position, monitoring industrial pump rotor displacement, and implementing machine protection systems on large rotating machinery in hazardous chemical or petrochemical processing environments.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\/Segment\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330130-080-01-CN\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable, armored, with China approval package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length Option\u003c\/td\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Connector Protector and Cable Option\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eArmored cable (Flexible AISI 302 or 304 SST with FEP outer jacket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix\u003c\/td\u003e\n\u003ctd\u003e-CN\u003c\/td\u003e\n\u003ctd\u003eChina hazardous area approval package (NEPSI + CCC + applicable markings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e330130-080-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eStandard Extension Cable (Armored)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 Ohm triaxial, FEP insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Construction\u003c\/td\u003e\n\u003ctd\u003eFlexible AISI 302 or 304 SST with FEP outer jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Outside Diameter\u003c\/td\u003e\n\u003ctd\u003e3.7 mm maximum (non-armored section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Outside Diameter\u003c\/td\u003e\n\u003ctd\u003e7.67 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Ferrule Diameter\u003c\/td\u003e\n\u003ctd\u003e10.2 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Strength\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lbf) probe case to probe lead; 270 N (60 lbf) at connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eGold-plated coaxial ClickLoc connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm x 250 mm x 40 mm (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eDuring installation, ensure the minimum bend radius of 25.4 mm is not exceeded to avoid degrading the triaxial insulation. When joining the ClickLoc connectors, tighten them finger tight; do not use pliers unless connecting non-XL stainless steel components. Use appropriate conduit or cable trays to route the armored section. Ensure that all shield and ground connections are properly terminated at the Proximitor sensor terminal strip to prevent external electrical noise interference.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Body\u003c\/th\u003e\n\u003cth\u003eApproved Rating \/ Package\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCC\u003c\/td\u003e\n\u003ctd\u003eChina Compulsory Certificate for explosive environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNEPSI\u003c\/td\u003e\n\u003ctd\u003eNational Supervision and Inspection Centre for Explosion Protection (China)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003ctd\u003eEuropean conformity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eDirective 2011\/65\/EU compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd\u003eSIL 2 \/ SIL 3 capable systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666869645675,"sku":"330130-080-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-080-01-cn-extension-cable-u545lf0jj4b_5cec69ed-77f7-4d01-ba2e-22cd0dd10c38.jpg?v=1765449579","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330130-080-01-cn-3300-xl-standard-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}