{"product_id":"bently-nevada-330703-000-050-10-02-05-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330703-000-050-10-02-05 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330703-000-050-10-02-05\u003c\/strong\u003e specifies a metric M14 x 1.5 threaded 3300 XL 11 mm proximity probe with 0 mm of unthreaded length, a 50 mm overall case length, a 1.0-meter total system length, standard coaxial cabling, and multiple global hazardous area agency approvals. This unarmored metric probe operates within the 3300 XL 11 mm Proximity Transducer System, measuring non-contact shaft vibration and axial position on high-speed rotating machinery.\u003c\/p\u003e\n\u003cp\u003eCompared to its armored counterparts or English-threaded configurations, this specific model utilizes standard 75-ohm triaxial cabling without flexible SST armor and is suited for installations inside protective conduits or where mechanical shielding is already provided.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMetric thread design: Features an M14 x 1.5 thread without flexible stainless steel protective armor.\u003c\/li\u003e\n  \u003cli\u003eFully threaded case: Configured with 0 mm unthreaded length and a compact 50 mm overall case length.\u003c\/li\u003e\n  \u003cli\u003eStandard triaxial cable: Supplied with a 1.0-meter (3.3 feet) standard FEP-insulated coaxial cable and standard Miniature ClickLoc connector without a connector protector.\u003c\/li\u003e\n  \u003cli\u003eMultiple hazardous area approvals: Certified for intrinsically safe and non-incendive installations under ATEX, IECEx, and North American standard agencies.\u003c\/li\u003e\n  \u003cli\u003eRobust construction: Utilizes a high-strength Polyphenylene Sulfide (PPS) tip and AISI 304 stainless steel probe case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used in a wide range of critical industrial monitoring applications, including:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial displacement monitoring.\u003c\/li\u003e\n  \u003cli\u003eCompressor and pump rotor position tracking inside industrial machinery trains.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator shaft deflection and thermal expansion monitoring.\u003c\/li\u003e\n  \u003cli\u003eRotating machinery protection under API 670 standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003ctr\u003e\n    \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n    \u003cth\u003eCode on This SKU\u003c\/th\u003e\n    \u003cth\u003eDescription\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eBase Model\u003c\/td\u003e\n    \u003ctd\u003e330703\u003c\/td\u003e\n    \u003ctd\u003e3300 XL 11 mm Probe, M14 x 1.5 thread, without armor\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n    \u003ctd\u003e000\u003c\/td\u003e\n    \u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n    \u003ctd\u003e050\u003c\/td\u003e\n    \u003ctd\u003e50 mm overall case length\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n    \u003ctd\u003e10\u003c\/td\u003e\n    \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eD - Connector and Cable Option\u003c\/td\u003e\n    \u003ctd\u003e02\u003c\/td\u003e\n    \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n    \u003ctd\u003e05\u003c\/td\u003e\n    \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003ctr\u003e\n    \u003cth\u003eParameter\u003c\/th\u003e\n    \u003cth\u003eSpecification Value\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eManufacturer\u003c\/td\u003e\n    \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePart Number\u003c\/td\u003e\n    \u003ctd\u003e330703-000-050-10-02-05\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n    \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eThread Size\u003c\/td\u003e\n    \u003ctd\u003eM14 x 1.5 metric thread\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n    \u003ctd\u003e0 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCase Length\u003c\/td\u003e\n    \u003ctd\u003e50 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTotal Length\u003c\/td\u003e\n    \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eArmor Option\u003c\/td\u003e\n    \u003ctd\u003eWithout armor\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCable Type\u003c\/td\u003e\n    \u003ctd\u003e75-ohm standard triaxial FEP-insulated coaxial cable\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eConnector Type\u003c\/td\u003e\n    \u003ctd\u003eMiniature coaxial ClickLoc connector (male)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eScale Factor\u003c\/td\u003e\n    \u003ctd\u003e3.94 V\/mm (100 mV\/mil) nominal\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eLinear Range\u003c\/td\u003e\n    \u003ctd\u003e4.0 mm (160 mils), typically from 0.5 mm to 4.5 mm (20 to 180 mils) gap\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eNominal Gap\u003c\/td\u003e\n    \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eFrequency Response\u003c\/td\u003e\n    \u003ctd\u003e0 Hz to 8 kHz (+0, -3 dB typical)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRecommended Target\u003c\/td\u003e\n    \u003ctd\u003eAISI 4140 steel, 30.5 mm (1.2 in) minimum diameter flat target\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n    \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n    \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd\u003e-51 degC to +177 degC (-60 degF to +351 degF)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePressure Sealing\u003c\/td\u003e\n    \u003ctd\u003eSealed via Viton O-ring between probe tip and case\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure proper mechanical and electrical performance, adhere to the following engineering guidelines during installation:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCable Routing: Maintain a minimum bend radius of 25.4 mm (1.0 in) for standard probe cables. Avoid sharp kinks or routing near high-voltage lines.\u003c\/li\u003e\n  \u003cli\u003eTorque Limits: Do not exceed the maximum rated installation torque of 63.3 N-m (560 in-lb) for the M14 x 1.5 thread case. The recommended installation torque is 21.1 N-m (187 in-lb).\u003c\/li\u003e\n  \u003cli\u003eProximity Gap Adjustment: Adjust probe gap to 2.5 mm (100 mils) nominal mechanical displacement, corresponding to -10 Vdc output voltage at the Proximitor sensor under standard conditions.\u003c\/li\u003e\n  \u003cli\u003eConnector Tightness: Connectors must be tightened finger-tight. Maximum torque must not exceed 0.565 N-m (5 in-lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL proximity transducer system is designed to meet rigorous global standards when configured with option 05 approvals:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eATEX\/IECEx: Certified intrinsically safe Ex ia IIC T5...T1 Ga and Ex ia IIIC T90C...T280C Dc for hazardous environments. Non-sparking Ex nA IIC T5...T1 Gc and increased safety Ex ec IIC T5...T1 Gc options are also supported.\u003c\/li\u003e\n  \u003cli\u003eNorth American Approvals (CSA): Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III.\u003c\/li\u003e\n  \u003cli\u003eEMC Directive: Complies with Directive 2014\/30\/EU standards including EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions).\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive: Complies with European Directive 2011\/65\/EU and meets China RoHS requirements with an EFUP rating of 15 years.\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: Certified SIL 2 capable (HFT=0) and SIL 3 capable (HFT=1) when implemented as part of an appropriate safety-instrumented system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666749583723,"sku":"330703-000-050-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330703-000-050-10-02-05-3300-xl-11-mm-probe-wznzlqvdeud_9ea90c43-2ab9-4383-8d92-7798829deee7.jpg?v=1765446988","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330703-000-050-10-02-05-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}