{"product_id":"bently-nevada-330703-000-060-10-02-cn-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330703-000-060-10-02-CN 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 000 (0 mm unthreaded length) and Option 060 (60 mm overall case length) specify the metric physical configuration of the \u003cstrong\u003e330703-000-060-10-02-CN\u003c\/strong\u003e 3300 XL 11 mm \u003cstrong\u003eproximity probe\u003c\/strong\u003e. This unarmored probe has a 1.0 m total length (Option 10) and is equipped with a miniature coaxial ClickLoc connector with standard cable (Option 02). This configuration is certified under the -CN China hazardous area approval package, providing NEPSI and CCC certifications for industrial safety compliance in regulated zones.\u003c\/p\u003e\n\n\u003cp\u003eCompared to standard imperial variants with 1\/2-20 UNF threads (such as the 330701 or 330702), the 330703 base model utilizes an M14 x 1.5 metric thread and does not feature stainless steel armor, facilitating installation through standard metric conduits. This probe integrates with a 3300 XL 11 mm Proximitor sensor and a 330730 extension cable to form a complete 5.0 m or 9.0 m transducer system, translating the physical gap between the probe tip and target into a proportional electrical voltage output.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM14 x 1.5 metric thread design without stainless steel armor.\u003c\/li\u003e\n  \u003cli\u003e0 mm unthreaded body length with 60 mm overall threaded case length.\u003c\/li\u003e\n  \u003cli\u003e1.0 meter (3.3 feet) standard coaxial cable length.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector for direct connection to extension cables.\u003c\/li\u003e\n  \u003cli\u003e-CN China hazardous area approval suffix, certifying the probe for NEPSI and CCC requirements.\u003c\/li\u003e\n  \u003cli\u003eViton O-ring integrated sealing material to prevent internal pressure leakage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eTypical heavy-industry scenarios where this 11 mm system is used include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTurbine shaft vibration and axial position monitoring.\u003c\/li\u003e\n  \u003cli\u003eRotor position and thrust measurement in heavy rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eIndustrial compressor and pump protection systems.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric and steam turbine generator shaft displacement monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330703-000-060-10-02-CN\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Probe, M14 x 1.5 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e000\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length (metric configuration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e60 mm overall case length (metric configuration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSuffix -CN\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-CN\u003c\/td\u003e\n      \u003ctd\u003eChina hazardous area approval package (NEPSI + CCC + applicable markings)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330703-000-060-10-02-CN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM14 x 1.5 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), beginning at approximately 0.5 mm to 4.5 mm (20 to 180 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/- 10% under standard calibration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance (R_probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.9 +\/- 0.5 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCalibration Target Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30.5 mm (1.2 in) flat surface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e152 mm (6.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Sealing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (with protected connectors)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure correct installation of the 3300 XL 11 mm probe by adhering to the following engineering guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e For M14 x 1.5 metric threads, the maximum length of thread engagement should not exceed 21 mm to prevent binding or physical case distortion.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e The outer shield of the coaxial cable must remain isolated from the machine ground. House the connections in insulated sleeves or a dedicated junction box.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e For environments exposed to moisture or oil, seal the ClickLoc connection using self-amalgamating tape or silicone-free connector protectors. Do not use standard silicone tape in contact with turbine oil.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap Setting:\u003c\/strong\u003e Calibrate and set the initial probe gap to the recommended standard setting of 2.5 mm (100 mils) using a digital voltmeter measuring the DC voltage of the Proximitor output.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBending Radius:\u003c\/strong\u003e Maintain the minimum bending radius of the standard coaxial cable (typically 25.4 mm or 1.0 inch) to avoid internal physical damage and signal attenuation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis product configuration is certified to comply with standard safety guidelines, containing local certifications designated by the -CN option suffix:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNEPSI:\u003c\/strong\u003e Explosion-proof certification for hazardous environments in China.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE \/ EMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU, meeting EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Directive 2011\/65\/EU and China RoHS compliance.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867188075,"sku":"330703-000-060-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330703-000-060-10-02-cn-extension-probe-0yvbmstbxhr_316143cd-5daf-4702-971b-b918d8516fce.jpg?v=1765449496","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330703-000-060-10-02-cn-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}