{"product_id":"bently-nevada-330851-02-000-060-50-00-00-3300-xl-25-mm-proximity-probe","title":"Bently Nevada 330851-02-000-060-50-00-00 3300 XL 25 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330851-02-000-060-50-00-00\u003c\/strong\u003e: 3300 XL 25 mm \u003cstrong\u003eproximity probe\u003c\/strong\u003e, M30x2 thread, Option 000 fully threaded metric case, Option 060 60 mm overall case length, Option 50 5.0 m total system length, Option 00 standard unarmored coaxial cable, Option 00 no agency approvals.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration incorporates an M30x2 metric thread (Option 02) and a 60 mm overall case length that is completely threaded (0.0 mm unthreaded). Operating as an eddy-current displacement sensor, this probe integrates with a 3300 XL 25 mm Proximitor sensor and a 3300 XL extension cable to measure large-target displacement. The integrated 5.0-meter PFA-insulated triaxial FluidLoc cable (Option 50) features front and rear seals that work together with the cable jacket to prevent moisture from entering the probe tip, maintaining electrical integrity in humid and harsh conditions. The clickLoc connector on the probe lead has a removable collar to simplify routing through tight clearances.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMetric Case Threading\u003c\/strong\u003e: M30x2 metric thread (Option 02) with 60 mm overall case length (Option 060) and 0.0 mm unthreaded length (Option 000) for fully threaded mounting configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated 5.0-Meter Cable\u003c\/strong\u003e: Option 50 specifies a 5.0-meter (16.4 feet) total system length with PFA-insulated, 75 ohm FluidLoc triaxial cable to prevent moisture and fluid migration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnarmored Design\u003c\/strong\u003e: Option 00 provides a flexible, non-armored cable configuration for direct installation where mechanical armor is not required.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGold-Plated ClickLoc Connectors\u003c\/strong\u003e: Supplied with corrosion-resistant ClickLoc miniature coaxial connectors featuring a removable nut collar on the probe lead.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Integrity\u003c\/strong\u003e: Option 00 agency approval option for non-hazardous locations or applications where specialized certifications are not needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDifferential expansion (DE) monitoring on mid-to-large-size steam turbine generators.\u003c\/li\u003e\n  \u003cli\u003eNon-contacting shaft vibration and axial position measurement on large rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eThrust position measurements on rotors with large axial travel.\u003c\/li\u003e\n  \u003cli\u003eRod-drop style applications on reciprocating compressors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330851\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 25 mm Proximity Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Probe Case Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eM30x2 thread (Metric, supplied with 38 mm lock nut and 27 mm wrench flats)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e000\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length (fully threaded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e60 mm overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 metres (16.4 feet) system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Armor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo Armor (PFA-insulated jacket only)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eF: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo Approvals (for use in general\/non-hazardous areas)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330851-02-000-060-50-00-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 25 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12.7 mm (500 mils) starting at 0.63 mm (25 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.31 mm (+\/-12 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 2.7 kHz: +0, -3 dB typical (with up to 305 m of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Minimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e61 mm (2.4 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Thread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM30x2 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 mm (fully threaded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, perfluoroalkoxyethylene (PFA) insulated FluidLoc probe cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyetheretherketone (PEEK)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo armor (standard outer PFA jacket only)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance (RPROBE)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.5 +\/- 0.8 ohms (center conductor to outer conductor for 5.0 m length)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLock Nut Wrench \/ Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e38 mm lock nut and 27 mm wrench flats\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector-to-Connector Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFinger tight recommended; maximum torque 0.565 N-m (5 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEnvironmental Limits (Probe Temperature)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOperating and Storage: -35 degC to +200 degC (-31 degF to +392 degF); Short-term: +250 degC (482 degF) max for less than 24 hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOption 00 (No Approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Component\u003c\/th\u003e\n      \u003cth\u003eSpecification \/ Type\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Lead Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated miniature ClickLoc coaxial female connector with removable nut collar\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExtension Cable Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConnects to 3300 XL 25 mm extension cable (such as model 330854)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass and gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure standard installation practices are followed for optimal transducer system operation:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Torque\u003c\/strong\u003e: For standard mount M30x2 thread probes, do not exceed the maximum rated torque of 163 N-m (120 ft-lb). The recommended mounting torque is 68 N-m (50 ft-lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocking\u003c\/strong\u003e: The probe case comes standard with a locknut featuring predrilled safety wire holes to prevent loosening under heavy vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMoisture Mitigation\u003c\/strong\u003e: All ClickLoc connectors must remain clean and free from oil, grease, and water. Connect each junction finger-tight, and utilize the provided silicon connector protectors or self-fusing tape for additional environmental isolation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRouting\u003c\/strong\u003e: The miniature coaxial connector's removable nut collar allows for easier routing through tight electrical conduits and clearances.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865877355,"sku":"330851-02-000-060-50-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330851-02-000-060-50-00-00-3300-xl-25-mm-proximity-probe-ypnvawbinpi_f0004be5-3971-4040-9b46-e116673fdd3f.jpg?v=1765449445","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330851-02-000-060-50-00-00-3300-xl-25-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}