{"product_id":"bently-nevada-330910-00-08-50-01-05-3300-nsv-proximity-probe","title":"Bently Nevada 330910-00-08-50-01-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330910-00-08-50-01-05\u003c\/strong\u003e specifies this 3300 NSv proximity probe configuration featuring an M10x1 metric thread with integral stainless steel armor. Option 00 specifies a fully threaded 0 mm unthreaded length, paired with an 80 mm overall case length (Option 08) and a 5.0 meter total system length (Option 50). This variant includes a miniature coaxial ClickLoc connector with a pre-installed connector protector (Option 01) and holds multiple international hazardous area certifications (Option 05).\u003c\/p\u003e\n\n\u003cp\u003eThis probe operates within the 3300 XL NSv proximity transducer system, which is used for non-contact displacement measurements where target areas are reduced or clearance is limited. The system employs a 3.2 mm tip diameter probe to obtain vibration and position signals on small-diameter shafts or targets with tight installation geometry, contrasting with larger 8 mm systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM10x1 metric thread with integrated flexible stainless steel armor to prevent mechanical abrasion of the cable.\u003c\/li\u003e\n  \u003cli\u003e0 mm unthreaded length (fully threaded case) allows maximum mounting depth adjustment.\u003c\/li\u003e\n  \u003cli\u003e80 mm overall case length provides mechanical reach inside machine housings.\u003c\/li\u003e\n  \u003cli\u003e5.0 meter total probe length matches system calibration requirements directly without short-length extensions.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector on standard FEP-insulated coaxial cable includes a factory-installed connector protector to seal out moisture and fluids.\u003c\/li\u003e\n  \u003cli\u003eMultiple hazardous area approvals under Option 05, including CSA, ATEX, and IECEx for Class I Zone 0, Zone 2, Division 1, and Division 2 installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position measurements on rotating machinery with shaft diameters smaller than 51 mm (2 inches).\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines, process gas compressors, centrifugal air compressors, refrigeration compressors, and auxiliary gearboxes.\u003c\/li\u003e\n  \u003cli\u003eTachometer, zero-speed, and phase reference (Keyphasor) measurements in tight spaces or recessed cavities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSegment \/ Option\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330910-00-08-50-01-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, M10x1 thread, with stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e08\u003c\/td\u003e\n      \u003ctd\u003e80 mm case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e01\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330910-00-08-50-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe (M10x1, armored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Size\u003c\/td\u003e\n      \u003ctd\u003eM10x1 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e3.2 mm (0.126 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Length\u003c\/td\u003e\n      \u003ctd\u003e80 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Length\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eStainless steel armor (flexible AISI 302 SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Protector\u003c\/td\u003e\n      \u003ctd\u003ePre-installed fluorosilicone connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from 0.25 to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Output \/ Scale Factor\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Weight (typical)\u003c\/td\u003e\n      \u003ctd\u003eApproximately 14 to 150 g (dependent on cable\/armor configuration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Maximum)\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to probe lead; 220 N (50 lb) probe case to stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing this proximity probe, maintain standard practices for eddy-current transducers. Ensure proper thread engagement with the machine casing to avoid binding (maximum recommended engagement for M10x1 threads is 15 mm). Use a class-matched thread fit to prevent thread stripping or damage. Grounding and shielding must conform to Bently Nevada standard drawings. The probe-to-extension cable connection must be secured and protected; if the connection is made inside the machine or exposed to turbine oil, use appropriate connector protectors or sealing tapes rather than general-purpose sleeves to maintain electrical signal insulation.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e Complies with European Community Directive 2014\/30\/EU (EN 61000-6-2 and EN 61000-6-4 for Industrial Environments).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Complies with European Community Directive 2011\/65\/EU and China RoHS requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e Meets standard classification rules for Offshore Units and Structures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (HFT = 0), SIL 3 certified (HFT = 1) when implemented as part of a complete safety-instrumented system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Certifications (Option 05):\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eClass I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga\u003c\/li\u003e\n      \u003cli\u003eClass I, Groups A, B, C, and D, Class II, Groups E, F, and G, Class III (Div 1\/Div 2)\u003c\/li\u003e\n      \u003cli\u003eATEX\/IECEx: Ex ia IIC T5...T1 Ga, Ex ia IIIC T90 degC...T280 degC Dc\u003c\/li\u003e\n      \u003cli\u003eATEX\/IECEx: Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666578272619,"sku":"330910-00-08-50-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330910-00-08-50-01-05-3300-nsv-probes-v51qmcecfb1_b0afb41f-c9cf-4cc5-ada7-9c96dabe1a58.jpg?v=1765440935","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330910-00-08-50-01-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}