{"product_id":"bently-nevada-330930-060-03-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-060-03-05 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-060-03-05\u003c\/strong\u003e specifies this 3300 NSv extension cable configuration, featuring a 6.0-meter length, no stainless steel armor, an integrated connector protector, and multiple hazardous area approvals. This industrial coaxial cable provides the critical connection between a 3300 NSv proximity probe and a 3300 XL NSv Proximitor sensor. It is engineered to transmit high-frequency eddy-current signals with minimal attenuation, maintaining calibrated system impedance for high-accuracy non-contact displacement measurements.\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL NSv transducer system is intended for rotating machinery with narrow target areas or restricted installation clearances, such as aeroderivative gas turbines, high-speed compressors, and small-bore pump shafts. This specific unarmored extension cable integrates a durable fluorosilicone connector protector that isolates the miniature ClickLoc coaxial connection from moisture, grease, and industrial cutting fluids, preventing impedance changes or signal dropouts.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise 6.0-Meter Length:\u003c\/strong\u003e Option 060 provides a 6.0-meter (19.7 feet) physical length to span distance between the machine casing and local junction boxes without excess slack.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnarmored Design with Connector Protector:\u003c\/strong\u003e Option 03 designates a flexible, lightweight coaxial cable without rigid metal armoring, combined with a pre-installed protective sleeve to seal the connection points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMultiple Hazardous Area Approvals:\u003c\/strong\u003e Option 05 qualifies the cable assembly for global safety certifications, including ATEX, IECEx, and CSA ratings for explosive or hazardous environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eImpedance-Matched 75-Ohm Design:\u003c\/strong\u003e Standardizes transmission characteristics to eliminate signal reflection and support high-fidelity vibration and axial position measurements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Coaxial Connectors:\u003c\/strong\u003e Corrosion-resistant, gold-plated brass connectors establish a positive lock that withstands persistent machine vibrations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position monitoring on high-speed aeroderivative gas turbines.\u003c\/li\u003e\n  \u003cli\u003eRadial dynamic motion measurements on small-bore machinery with narrow shaft targets.\u003c\/li\u003e\n  \u003cli\u003eVibration monitoring on centrifugal compressors and high-speed turbopumps.\u003c\/li\u003e\n  \u003cli\u003eRestricted-clearance machinery installations where rigid stainless steel armor is not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-060-03-05\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable (6.0 meters, unarmored with connector protector, multiple approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eWithout stainless steel armor, with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple approvals (CSA, ATEX, IECEx, etc.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930-060-03-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75-ohm coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (Unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature ClickLoc coaxial connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIncluded (fluorosilicone material)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCenter Conductor Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.220 ohm\/m (0.067 ohm\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShield Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.066 ohm\/m (0.020 ohm\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe-lead-to-extension-cable connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 g\/m (0.5 oz\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Length Match:\u003c\/strong\u003e Ensure that the combined physical length of the proximity probe and this extension cable matches the exact system length of the Proximitor sensor (typically 5.0 meters or 7.0 meters).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Cleanliness:\u003c\/strong\u003e Keep the miniature coaxial connectors clean and free of oil, water, and contaminants prior to mating. Moisture or debris inside the connector will degrade system calibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Torque:\u003c\/strong\u003e ClickLoc coaxial connectors must be joined finger-tight. The maximum rated torque limit is 0.56 Nm (5 in-lb) to prevent damage to the gold-plated contacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRouting and Bend Limits:\u003c\/strong\u003e Route the cable through protective conduit or cable trays where possible. Maintain a minimum bend radius of 25.4 mm (1.0 in) during installation to prevent internal conductor breakage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Ensure the option 03 connector protector is fully seated over the connection point to isolate the mated junction from surrounding environmental spray.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T5...T1 Ga\u003cbr\u003eEx ia IIIC T90C...T280C Dc (for EPL Dc)\u003cbr\u003eEx nA IIC T5...T1 Gc\u003cbr\u003eEx ec IIC T5...T1 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCSA \/ NRTL \/ C\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClass I, Zone 0\/2: AEx\/Ex ia IIC \/ nA IIC \/ ec IIC T5...T1 Ga\/Gc\u003cbr\u003eClass I, Division 1 \u0026amp; 2, Groups A, B, C, D\u003cbr\u003eClass II, Groups E, F, G\u003cbr\u003eClass III\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSIL 2 Certified (HFT = 0)\u003cbr\u003eSIL 3 Certified (HFT = 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Directives\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEMC Directive 2014\/30\/EU\u003cbr\u003eStandards: EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRoHS\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEuropean Directive 2011\/65\/EU Compliant\u003cbr\u003eChina RoHS: 15-year EFUP designation\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666531610987,"sku":"330930-060-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-060-03-05-3300-nsv-extension-cable-whkdcm1qppx_7230ffde-b390-4693-b00c-771483dd8653.jpg?v=1765440363","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-330930-060-03-05-3300-nsv-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}