{"product_id":"bently-nevada-3500-05-01-02-00-00-00-3500-system-rack","title":"Bently Nevada 3500\/05-01-02-00-00-00 Baie système 3500","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/05-01-02-00-00-00\u003c\/strong\u003e functions as a full-size 19-inch system rack designed by Bently Nevada for the 3500 Machinery Condition Monitoring System. This hardware framework provides structural mounting positions for all 3500 series monitor modules and power supply units, facilitating high-speed backplane communication and clean power distribution between adjacent components. This specific model configuration features 14 available module slots and uses a 19-inch EIA rack mount format, which permits secure attachment to standard equipment rails.\u003c\/p\u003e\n\u003cp\u003eEngineered to optimize panel layout efficiency, the \u003cstrong\u003e3500\/05-01-02-00-00-00\u003c\/strong\u003e positions all field wiring terminations and input\/output (I\/O) modules at the rear of the chassis structure for accessible maintenance. The design mandates that primary power supplies and the rack interface module occupy the far-left slot positions, reserving the remaining slots for custom operational combinations of monitoring, protection, and display hardware.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Chassis Layout:\u003c\/strong\u003e Incorporates a full-size 19-inch EIA rack infrastructure provisioning 14 dedicated slots for monitoring and control modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Rail Interfacing:\u003c\/strong\u003e Utilizes the option 02 rack mount format to integrate directly into conventional industrial 19-inch EIA hardware enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear I\/O Accessibility:\u003c\/strong\u003e Configured to expose all critical wiring paths and input\/output modules on the rear plane for streamlined serviceability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Communication Backplane:\u003c\/strong\u003e Enables adjacent modules to intercommunicate across high-speed bus lines built directly into the rear panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrganized Power Distribution:\u003c\/strong\u003e Built to securely host core system power modules at the far-left edge to regulate and balance supply lanes across the chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure mounting for 3500 series machinery condition monitoring hardware loops \u003c\/li\u003e\n\u003cli\u003eCentralized rack hosting for vibration, position, and speed modules \u003c\/li\u003e\n\u003cli\u003eStandard 19-inch cabinet deployment in refining, petrochemical, and power generation control rooms \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Parameter Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Description: System Rack \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Size: 19-inch Rack (14 module slots) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Option: Rack Mount Option, Full-Size Rack (mounts to 19-inch EIA Rack) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: None \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReserved: None \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Compliance Option: None \/ Omitted \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500 Series Machinery Condition Monitoring \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Dimensions (Width)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e482.60 mm (19.000 inches) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Dimensions (Height)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265.94 mm (10.470 inches) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Dimensions (Depth)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e246.38 mm (9.700 inches) \/ 349.25 mm (13.750 inches) base depth \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Available Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 slots (excluding power supply and interface assignments) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Form Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch EIA rack mount configuration \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Software Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMini-rack variants require Version 2.70 or later of 3500\/01 Software \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDocument Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e141525 Rev. K \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Positioning Restriction:\u003c\/strong\u003e Ensure that core system power supplies and the primary rack interface module are locked exclusively into the far-left locations of the chassis framework.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEIA Rail Attachment:\u003c\/strong\u003e Line up the chassis mounting brackets with standard 19-inch EIA rails and secure using structural screws to withstand physical machinery vibrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBarrier Depth Adjustments:\u003c\/strong\u003e If planning to plant internal barriers within the assembly, adjust clearance dimensions to accommodate an expanded depth baseline of 422.91 mm (16.650 inches).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Space Requirements:\u003c\/strong\u003e Provide sufficient clear workspace behind the mounting enclosure to ensure unhindered field wire termination and manual I\/O card attachment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules regarding industrial signal interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e Evaluated under EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Certified in alignment with the Low Voltage Directive 2014\/35\/EU and EN 61010-1 standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals:\u003c\/strong\u003e Formally qualified under American Bureau of Shipping (ABS) rules and DNV GL classification guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666735526251,"sku":"3500\/05-01-02-00-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-05-01-02-00-00-00-system-rack-yd0fglpupxk_6feaee9c-ffe9-478c-8ce9-d527a2f032d3.jpg?v=1765446782","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-3500-05-01-02-00-00-00-3500-system-rack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}