{"product_id":"bently-nevada-3500-05-01-02-00-00-01-system-rack","title":"Rack système Bently Nevada 3500\/05-01-02-00-00-01","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/05-01-02-00-00-01\u003c\/strong\u003e is a full-size, 19-inch \u003cstrong\u003eSystem Rack\u003c\/strong\u003e manufactured by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e (a Baker Hughes business) designed as the foundational structural framework for the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. This hardware serves as the physical chassis and high-speed backplane hub that houses all core 3500 series machinery vibration monitors, transient data interfaces, and system power supplies. The integrated digital backplane allows distinct instrumentation slots to seamlessly exchange real-time control data, while simultaneously supplying a highly filtered internal power distribution grid to each individual slide-in module.\u003c\/p\u003e\n\u003cp\u003eThe exact ordering configuration code \u003cstrong\u003e3500\/05-01-02-00-00-01\u003c\/strong\u003e details a \u003cstrong\u003e19-inch full-size structural chassis containing 14 available instrumentation slots\u003c\/strong\u003e (excluding the dedicated left-hand utility power and rack interface module positions). It features a \u003cstrong\u003eBulkhead Mount\u003c\/strong\u003e structural format option, meaning it is engineered to mount directly flat against a wall, structural bulkhead panel, or within a custom enclosure where traditional 19-inch EIA open-frame relay rails are unavailable. All underlying input\/output field terminations, transducer loops, and backend I\/O modules are fully accessible directly from the front panel interface in this layout option. This model contains \u003cstrong\u003eEuropean Compliance (CE)\u003c\/strong\u003e certifications and is standard production series hardware.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCentral high-speed communication backplane enabling real-time processing interaction between protection cards.\u003c\/li\u003e\n\u003cli\u003eFull-size 19-inch instrumentation architecture offering 14 discrete, customizable module expansion slots.\u003c\/li\u003e\n\u003cli\u003eBulkhead mount design allowing flush vertical surface installation where traditional 19-inch cabinet rails are absent.\u003c\/li\u003e\n\u003cli\u003eFront-access I\/O capability ensuring field sensor loops and external terminations can be fully wired from the front.\u003c\/li\u003e\n\u003cli\u003eRigid industrial-grade structural metal build to damp ambient high-frequency vibration and shield against magnetic interference.\u003c\/li\u003e\n\u003cli\u003eFull European Compliance (CE) approval rating factory-certified for reliable implementation across European industrial assets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary localized equipment rack holding machinery protection cards for large utility steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003ePlant-wide central safety interlock and predictive maintenance monitoring hub on high-vibration compression trains.\u003c\/li\u003e\n\u003cli\u003eBulkhead-mounted field enclosures used inside harsh oil and gas refinery or petrochemical control rooms where rear access is blocked.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOption String Breakdown\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/05\u003c\/td\u003e\n\u003ctd\u003eSystem Rack Product Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Rack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003e19-inch Rack (14 usable module slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Mounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-02\u003c\/td\u003e\n\u003ctd\u003eBulkhead Mount Option, Full-Size Rack format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eNone (Standard safety area classification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Reserved Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00\u003c\/td\u003e\n\u003ctd\u003eNone (Factory baseline configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: European Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eCE Approved (European Compliance certification label included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Variant ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/05-01-02-00-00-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCondition Monitoring System Chassis Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Available Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 slots for standard monitors, plus 2 dedicated left positions for Power\/RIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Mounting Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBulkhead surface integration with front-facing I\/O wiring access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Framework Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e482.60 mm (Standard 19-inch footprint)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Framework Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265.94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Framework Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e349.25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAverage Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 13.6 kg (30 lbs) to 20.4 kg (45 lbs) empty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy-gauge aluminum and structural sheet metal alloys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround Reference Target\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated copper ground lugs provided on the chassis grid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eStructural Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Bus Backplane\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-density pin array distributing internal DC power and control logic between slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront I\/O Panel Space\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBulkhead configuration routing slide-in external field sensor termination blocks to the front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Ground Lug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty copper stud point connecting the rack frame to structural earth safety grounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBulkhead Surface Preparation:\u003c\/strong\u003e Verify the wall or structural panel can continuously support the weight of a fully populated 3500 rack (up to 45 lbs or 20.4 kg). Pre-drill mounting holes to match the exact template spacing provided in Bently Nevada installation manuals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Access Clearances:\u003c\/strong\u003e Because this is a Bulkhead Mount (-02) chassis, both the primary monitor cards and their corresponding I\/O modules install from the front. Maintain a minimum of 250 mm clearance in front of the rack face for cable bending radiuses, wiring trunking, and module removal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Utility Slot Rules:\u003c\/strong\u003e Remember that the far left slots are dedicated exclusively to the power supply modules (such as the 3500\/15) and the Rack Interface Module (3500\/22M). Standard machinery monitors cannot be forced into these utility slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Earth Ground Link:\u003c\/strong\u003e Connect a heavy-gauge copper grounding wire from the main chassis earth stud to the primary electrical ground grid of the control panel enclosure to block electrical noise and ensure instrumentation stability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666764362091,"sku":"3500\/05-01-02-00-00-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-05-01-02-00-00-01-system-rack-5ktnha1utrv_b8f01905-49ca-426f-9031-897972de17f9.jpg?v=1765447193","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-3500-05-01-02-00-00-01-system-rack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}