{"product_id":"bently-nevada-3500-32m-149986-02-4-channel-relay-module","title":"Module relais 4 canaux Bently Nevada 3500\/32M 149986-02","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/32M\u003c\/strong\u003e with spare part number \u003cstrong\u003e149986-02\u003c\/strong\u003e is a full-height module that delivers four highly configurable relay outputs for auto-trip execution and interlocking machinery protection. This \u003cstrong\u003e3500\/32M 149986-02\u003c\/strong\u003e module populates any designated slot located to the right of the Transient Data Interface (TDI) module inside a standard 3500 rack. Each relay output operates independently and can be programmed with sophisticated Alarm Drive Logic, integrating complex AND\/OR voting logic combinations that evaluate Alert, Danger, Not-OK, and individual Proprietary Logic (PPL) variables sourced from any channel or group of channels across the protection chassis via the configuration utility.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour fully independent single-pole double-throw (SPDT) relay channels.\u003c\/li\u003e\n\u003cli\u003eCustom voting configurations utilizing comprehensive onboard Alarm Drive Logic functions.\u003c\/li\u003e\n\u003cli\u003eFactory-installed 250 Vrms arc suppressors on each channel as a standard build feature.\u003c\/li\u003e\n\u003cli\u003eHardware-switch-selectable operations allowing independent Normally De-energized or Normally Energized assignments.\u003c\/li\u003e\n\u003cli\u003eFront panel status tracking via distinct OK, TX\/RX, and individual CH ALARM LEDs.\u003c\/li\u003e\n\u003cli\u003eSealed contact assemblies featuring epoxy protection barriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency machinery shutdown loop initiation for industrial rotating equipment.\u003c\/li\u003e\n\u003cli\u003eFunctional safety (SIL) machine trip systems.\u003c\/li\u003e\n\u003cli\u003eCritical multi-channel voting interlock setups for high-speed gas or steam turbines.\u003c\/li\u003e\n\u003cli\u003eHazardous zone status annunciator signaling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpare Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e149986-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel Relay Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, double-throw (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArc Suppression\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms installed as standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Life Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 cycles @ 5 A, 24 Vdc or 240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Minimum Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard DC Contact Rating (Resistive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 0V to 30 Vdc, 0.75 A @ 48 Vdc, 0.2 A @ 125 Vdc (125 Vdc max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard AC Contact Rating (Resistive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 250 Vac max (450 VA max switched power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\/Hazardous Minimum Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 12 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\/Hazardous DC Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 0V to 30 Vdc (30 Vdc maximum switched voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety\/Hazardous AC Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A @ 30 Vac maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (1.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 242 mm (9.50 in. x 0.96 in. x 9.52 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in. x 0.96 in. x 3.90 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Space Allocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot (Main), 1 full-height rear slot (I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Selection:\u003c\/strong\u003e Slide the full-height front module into any available user slot located to the right of the Transient Data Interface (TDI) module inside the 3500 chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Connection Assembly:\u003c\/strong\u003e Align and seat the matching 4-channel relay I\/O module in the corresponding full-height rear slot directly behind the main control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Operating Setup:\u003c\/strong\u003e Adjust the onboard physical switches to define the baseline state as Normally De-energized (ND) or Normally Energized (NE) for each individual channel before field wiring is tied in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Retention:\u003c\/strong\u003e Secure the front-panel panel fasteners fully to ground the module housing properly to the chassis structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Integration:\u003c\/strong\u003e Establish connection parameters, input tracking channels, and custom AND\/OR structures using the 3500 Rack Configuration Software prior to going live.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety Precautions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Restriction Compliance:\u003c\/strong\u003e When used in systems ordered with hazardous area approvals (Division 2\/Zone 2 certified), the relay voltages must be strictly restricted to a maximum of 30 Vdc or 30 Vac. The module layout does not support standard increased physical spacing rules required for higher operating voltages under these certifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety (SIL) Limit:\u003c\/strong\u003e If integrated as a component within an active functional safety (SIL) loop, higher voltages are strictly prohibited. The functional safety certificate mandates adherence to the limited voltage levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Shock Hazard:\u003c\/strong\u003e Isolate all external field wiring and circuits prior to working on terminal strips. This module can expose conductors to potential contact, introducing severe electrical burn or shock hazards under high-voltage configurations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850345323,"sku":"3500\/32M 149986-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-32m-149986-02-4-channel-relay-module-jpukccfwkaz_1a867c4f-eb20-4adb-ab0a-439738ac47ac.jpg?v=1765449025","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-3500-32m-149986-02-4-channel-relay-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}