{"product_id":"bently-nevada-3500-50-133388-02-tachometer-module","title":"Module tachymètre 3500\/50 Bently Nevada 133388-02","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/50\u003c\/strong\u003e, designated under spare part number \u003cstrong\u003e133388-02\u003c\/strong\u003e, is a 2-channel hardware component engineered to determine shaft rotative speed, rotor acceleration, or rotor direction within the 3500 Machinery Protection System. The module interfaces directly with raw proximity probe transducers or passive magnetic pickups to monitor physical asset dynamics. Acting as an analytical interface layer, it continuously compares acquired frequency data against user-programmable alarm setpoints, changing states to trip automated safety alarms when thresholds are exceeded. Configurable through the 3500 Rack Configuration Software, the module can supply conditioned Keyphasor signals to the backplane network, eliminating the need for independent Keyphasor hardware installations. The instrument outputs an independent +4 to +20 mA analog recorder signal for each measurement channel to supply plant operations and logging utilities with deterministic diagnostic indicators.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual independent channel capabilities for multi-point frequency or rotational direction tracking.\u003c\/li\u003e\n\u003cli\u003eVersatile sensor acceptance supporting both eddy current proximity systems and passive magnetic pickups.\u003c\/li\u003e\n\u003cli\u003eFour standard firmware options comprising speed monitoring, speed band, zero speed, acceleration, and reverse rotation tracking.\u003c\/li\u003e\n\u003cli\u003eIntegrated peak hold logic capturing maximum forward speed, maximum reverse speed, and cumulative reverse rotations.\u003c\/li\u003e\n\u003cli\u003eInternal rack signal distribution delivering conditioned Keyphasor reference data to adjacent 3500 series monitors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial steam and gas turbine rotor shaft speed tracking and peak rotation monitoring.\u003c\/li\u003e\n\u003cli\u003eCentrifugal process gas compressor acceleration observation and emergency shutdown interface.\u003c\/li\u003e\n\u003cli\u003eLarge-scale cooling tower fan zero speed validation and reverse rotation notification.\u003c\/li\u003e\n\u003cli\u003eHigh-horsepower industrial gearbox input-to-output shaft speed ratio monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/50-AXX-BXX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTachometer Module\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: I\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Terminations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with External Terminations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eTMR I\/O Module with External Terminations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eI\/O Module with Internal Barriers and Internal Terminations \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Monitor Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eSpeed Measurement \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eReverse Rotation \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e133388-02\u003c\/td\u003e\n\u003ctd\u003e3500\/50 Tachometer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/50 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e133388-02 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Input Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 proximity probe transducers or magnetic pickups \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+10.0 V to -24.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTMR Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Barrier Input Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.15 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 Watts typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Proportional Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA DC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Voltage Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc across load \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Load Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 600 Ω \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Supply Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc, 40 mA maximum per channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Supported Input Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kHz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Full Scale Speed Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99,999 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximity Probe Frequency Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 0.0167 Hz (1 rpm for 1 event\/revolution) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMagnetic Pickup Frequency Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 3.3 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM Accuracy (\u0026lt; 100 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.1 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM Accuracy (100 to 10,000 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±1 rpm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM Accuracy (\u0026gt; 10,000 rpm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.01% of true shaft speed \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRotor Acceleration Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±20 rpm\/min \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Triggering Amplitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 1 volt peak-to-peak \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManual Triggering Scope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+9.5 Vdc to -23.5 Vdc with 500 mV peak-to-peak minimum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Trigger Hysteresis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser selectable from 0.2 to 2.5 volts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm 1 Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 60 seconds in 1 second intervals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm 2 Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 60 seconds in 0.1 second intervals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp (Standard I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 Celsius to +65 Celsius (-22 Fahrenheit to +150 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp (Barrier I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Celsius to +65 Celsius (32 Fahrenheit to +150 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 Celsius to +85 Celsius (-40 Fahrenheit to +185 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing relative humidity \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Monitor Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg (1.8 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight (Non-Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight (Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg (1.01 lbs) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Monitor Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (Non-Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (Barrier)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 163.1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Rack Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot and 1 full-height rear slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Connector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH1 BNC (Front Face)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Transducer Coaxial Output for Channel 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCH2 BNC (Front Face)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Transducer Coaxial Output for Channel 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O TRANSDUCERS (CHI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePWR \/ COM \/ SIG \/ SHLD Terminal Blocks for Sensor Input 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O TRANSDUCERS (CH2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePWR \/ COM \/ SIG \/ SHLD Terminal Blocks for Sensor Input 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCONTACTS Terminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRESET (PRST1 \/ PRST2) and Zener Barrier Enable Interlocks \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUFFERED TRANSDUCERS Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuffered Euro-style Output Pins for External Oscilloscopes \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRECORDER OUTPUTS Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated COM \/ REC1 \/ REC2 \/ SHLD Current Loop Interfaces \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGrounding Control: Terminate field sensor cable shields explicitly at the designated SHLD pins on the rear termination blocks to build an effective faraday path against high-frequency electrical noise.\u003c\/li\u003e\n\u003cli\u003eSlot Alignment: Insert the main front module into any available full-height slot location, pushing firmly along the alignment tracks until the card engages with the rack backplane power lines.\u003c\/li\u003e\n\u003cli\u003eSensor Exclusions: Do not map magnetic pickup inputs to zero speed or reverse rotation notification functions, as low shaft velocity cannot generate sharp edge signals for proper trigger interpretation.\u003c\/li\u003e\n\u003cli\u003eVentilation Integrity: Ensure clearance tracks are maintained on both the front face and rear interface regions to facilitate ambient forced-air cooling paths through the instrument chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Mark Directives: EN50081-2 Radiated and Conducted Emissions (Class A), EN50082-2 Industrial Susceptibility Standard.\u003c\/li\u003e\n\u003cli\u003eLow Voltage Directives: EN 61010-1 Environmental Safety Requirements for Electrical Equipment.\u003c\/li\u003e\n\u003cli\u003eCSA \/ NRTL \/ C: Certified for Class I, Division 2, Groups A through D installations when combined with matching standard termination modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this instrument independently control plant machinery overspeed trip valves?\u003c\/strong\u003e A: No, Bently Nevada tachometer modules are not engineered as components for standalone speed control or direct overspeed protection, as they lack the critical structural redundancy needed for machinery trip functions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the physical operational difference between part number 133388-02 and the 3500\/50 series designation?\u003c\/strong\u003e A: The 3500\/50 identifies the overall functional tachometer module design family, while the reference 133388-02 dictates the specific warehouse spare component identifier for the front card assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is manual calibration necessary for the analog output loop upon deployment?\u003c\/strong\u003e A: No field-level calibration routines are necessary, since all transmitter input ranges, voltage thresholds, and discrete parameters are processed digitally using the 3500 software layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a magnetic pickup be safely assigned to verify reverse rotation behavior?\u003c\/strong\u003e A: No, passive magnetic pickups fail to deliver a distinct or clean signal edge during slow or stopping shaft cycles, which can cause severe faults or incorrect direction tracking within the logic layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does a sudden external short circuit on the analog recorder loop affect overall speed tracking?\u003c\/strong\u003e A: The primary speed tracking, alarm monitoring, and backplane processing operations remain completely uninfluenced by short-circuit faults across the external recorder line loops.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519552363,"sku":"3500\/50 133388-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-50-133388-02-tachometer-module-fzrkzbolckl_a2fc124d-c18b-438a-9eb8-c8d07efe8699.jpg?v=1765440133","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-3500-50-133388-02-tachometer-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}