{"product_id":"bently-nevada-3500-61-02-00-133827-02-temperature-monitor-rtd-tc-non-isolated-i-o-module","title":"Module d'entrée\/sortie non isolé pour moniteur de température RTD\/TC Bently Nevada 3500\/61-02-00 133827-02","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/61-02-00\u003c\/strong\u003e is a six-channel temperature monitoring module designed for the \u003cstrong\u003eBently Nevada 3500 Machinery Protection System\u003c\/strong\u003e. The module accepts both RTD and thermocouple temperature inputs and performs continuous temperature measurement and alarm comparison functions for critical rotating machinery applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e133827-02\u003c\/strong\u003e RTD\/TC Non-Isolated I\/O Module uses external terminations and supports mixed RTD and TC input configurations. Users can configure individual channels through the 3500 Rack Configuration Software for RTD or thermocouple operation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/61\u003c\/strong\u003e series differs from the \u003cstrong\u003e3500\/60\u003c\/strong\u003e by providing recorder outputs for each monitoring channel. Recorder outputs support 4 to 20 mA transmission proportional to the configured monitor full-scale range.\u003c\/p\u003e\n\u003cp\u003eThe module supports up to six transducer inputs and provides programmable Alert and Danger alarm setpoints. In Triple Modular Redundant (TMR) systems, temperature monitors install adjacent in groups of three to support redundant voting logic and fault tolerance.\u003c\/p\u003e\n\u003cp\u003eThe module is suitable for turbine monitoring systems, compressor trains, process plants, power generation facilities, and industrial machinery protection applications requiring temperature supervision and alarm processing.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSix-channel temperature monitoring\u003c\/li\u003e\n\u003cli\u003eSupports RTD and thermocouple inputs\u003c\/li\u003e\n\u003cli\u003eMixed RTD and TC channel configuration supported\u003c\/li\u003e\n\u003cli\u003eExternal termination non-isolated I\/O design\u003c\/li\u003e\n\u003cli\u003eRecorder outputs for all six channels\u003c\/li\u003e\n\u003cli\u003eUser-configurable alarm setpoints\u003c\/li\u003e\n\u003cli\u003eSoftware configurable RTD or TC measurement mode\u003c\/li\u003e\n\u003cli\u003eCompatible with 3500 Rack Configuration Software\u003c\/li\u003e\n\u003cli\u003eSupports TMR system architecture\u003c\/li\u003e\n\u003cli\u003eFront panel OK, TX\/RX, and Bypass LEDs\u003c\/li\u003e\n\u003cli\u003e4 to 20 mA recorder outputs\u003c\/li\u003e\n\u003cli\u003eChannel full-scale configuration through software\u003c\/li\u003e\n\u003cli\u003eNo calibration required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine temperature monitoring\u003c\/li\u003e\n\u003cli\u003eGas turbine protection systems\u003c\/li\u003e\n\u003cli\u003eCompressor temperature supervision\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating machinery monitoring\u003c\/li\u003e\n\u003cli\u003eProcess plant shutdown systems\u003c\/li\u003e\n\u003cli\u003ePower generation equipment protection\u003c\/li\u003e\n\u003cli\u003ePetrochemical process monitoring\u003c\/li\u003e\n\u003cli\u003eLNG facility machinery monitoring\u003c\/li\u003e\n\u003cli\u003eCritical equipment alarm systems\u003c\/li\u003e\n\u003cli\u003eTMR machinery protection installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3500\/61-02-00: Complete RTD\/TC Monitor Kit with External Terminations\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifies the combined kit containing the 3500\/61 main monitor module and the specific non-isolated rear I\/O board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02: I\/O Module Type Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRTD\/TC Non-isolated I\/O Module with External Terminations (Rear Board Part Number: \u003cstrong\u003e133827-02\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00: Agency Approval Option\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eNo hazardous area agency approvals or certifications required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpares \u0026amp; Accessories\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePart Number \u003cstrong\u003e133827-02\u003c\/strong\u003e: Replacement 3500\/61 RTD\/TC Non-Isolated I\/O Module with External Terminations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTemperature Monitor RTD\/TC Non-Isolated I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/61-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Part Number\u003c\/td\u003e\n\u003ctd\u003e133827-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1 to 6 RTD or TC transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 Mohm for each lead input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Compliance\u003c\/td\u003e\n\u003ctd\u003e0 to +12 Vdc across load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd\u003e0 to 600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.3662 uA per bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Current Source\u003c\/td\u003e\n\u003ctd\u003e925 +\/-15 uA at 25 degC per transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Delay Range\u003c\/td\u003e\n\u003ctd\u003eAlert: 1 to 60 s, Danger: 1 to 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Dimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 x 24.4 x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Weight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 x 24.4 x 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Slot Requirement\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot and 1 rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRTD Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Type\u003c\/td\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 ohm Platinum RTD Alpha 0.00385\u003c\/td\u003e\n\u003ctd\u003e-200 degC to +850 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 ohm Platinum RTD Alpha 0.00392\u003c\/td\u003e\n\u003ctd\u003e-200 degC to +700 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120 ohm Nickel RTD\u003c\/td\u003e\n\u003ctd\u003e-80 degC to +260 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 ohm Copper RTD\u003c\/td\u003e\n\u003ctd\u003e-100 degC to +260 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eThermocouple Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Type\u003c\/td\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003ctd\u003e-100 degC to +1000 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003ctd\u003e-18 degC to +760 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003ctd\u003e-18 degC to +1370 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003ctd\u003e-160 degC to +400 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Conditioning Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD and TC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper RTD Resolution\u003c\/td\u003e\n\u003ctd\u003e1 degC or 1 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Junction Compensation Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-1 degC at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Accuracy\u003c\/td\u003e\n\u003ctd\u003eWithin 0.13% of desired value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Termination Non-Isolated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-1 degC at 25 degC standard rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBulkhead Rack Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-3 degC at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOutputs and Indicators\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicator or Output\u003c\/td\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK LED\u003c\/td\u003e\n\u003ctd\u003eIndicates proper monitor operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX\/RX LED\u003c\/td\u003e\n\u003ctd\u003eIndicates communication with rack modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBypass LED\u003c\/td\u003e\n\u003ctd\u003eIndicates bypass mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003eIndividual 4 to 20 mA outputs per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatinum RTD Selection\u003c\/strong\u003e: Platinum RTDs with a 0.00385 alpha coefficient conform to global industrial standards and are recommended for all new temperature loop deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder Short-Circuit Immunity\u003c\/strong\u003e: Internal circuitry ensures that the core machinery monitoring and alarm logic remain unaffected by short circuits on external recorder loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnder and Over Setpoints\u003c\/strong\u003e: The internal processing engine provides both upper and lower alarm bounds for multi-directional protection (e.g., cryogenic or overheating states).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTMR Requirements\u003c\/strong\u003e: When configured for Triple Modular Redundancy, three identical temperature monitors must reside in consecutive, adjacent front-chassis slots.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Termination Wiring\u003c\/strong\u003e: Route all RTD or TC lead wires to the external termination block ensuring clean, gas-tight connections to maintain CJC accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Terminate the cable shields exclusively at the designated shield grounding terminal on the I\/O module to prevent ground loops and shield against electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJC Sensor Matching\u003c\/strong\u003e: Ensure the Cold Junction Compensation sensor is securely mounted to the terminal base for accurate ambient compensation during thermocouple measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead Resistance Minimization\u003c\/strong\u003e: For 3-wire and 4-wire RTD hookups, keep lead wire lengths identical to balance line-drop and ensure accurate bridge compensation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between the 3500\/60 and the 3500\/61 modules?\u003c\/strong\u003e A: Both modules provide identical temperature monitoring and alarm logic, but the 3500\/61 features six independent +4 to +20 mA individual recorder outputs whereas the 3500\/60 does not.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this specific non-isolated I\/O module option provide channel-to-channel isolation?\u003c\/strong\u003e A: No, this is the 02 option which is non-isolated; if channel-to-channel isolation is needed to counteract heavy ground faults or high-voltage line crossovers, the isolated I\/O module version should be specified instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is field calibration required for the 3500\/61 module upon installation?\u003c\/strong\u003e A: No field calibration is required as full-scale ranges and sensor types are configured digitally using the 3500 Rack Configuration Software.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847691115,"sku":"3500\/61-02-00 133827-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-02-00-133827-02-rtd-tc-temperature-i-o-module-tul1fywpxs1_6cd7fe54-1ece-464e-8d43-bdb06cb565fb.jpg?v=1765448969","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-3500-61-02-00-133827-02-temperature-monitor-rtd-tc-non-isolated-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}