{"product_id":"bently-nevada-3500-93-135785-01-system-display-unit","title":"Bently Nevada 3500\/93 135785-01 Unité d'affichage système","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/93\u003c\/strong\u003e display system is used for local visualization of rack monitoring data within the Bently Nevada 3500 Machinery Protection System. The \u003cstrong\u003e135785-01\u003c\/strong\u003e display unit provides an LCD interface for viewing channel measurements, alarm conditions, rack status information, and other monitored variables from installed modules.\u003c\/p\u003e\n\u003cp\u003eThe display assembly operates together with a display interface module and a display interface I\/O module. Front membrane keypad controls allow operators to navigate through channel data, alarm events, and rack operating conditions directly from the display panel.\u003c\/p\u003e\n\u003cp\u003eA single 3500 rack can support up to two display units for additional monitoring visibility in machinery protection cabinets or remote operator locations. The display can be mounted directly on the rack front panel or installed remotely in a separate enclosure depending on system layout requirements.\u003c\/p\u003e\n\u003cp\u003eFront-panel LEDs provide visual indication of channel status, rack condition, and active alarm states during operation and maintenance activities.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConsolidates and displays real-time machinery parameter data collected from all active rack channels.\u003c\/li\u003e\n\u003cli\u003eBuilt-in keypad control panel enables seamless operator navigation and localized display interface control.\u003c\/li\u003e\n\u003cli\u003eIntegrated multi-segment LED system provides clear indications for Channel Status, New Alarm Events, Display Unit Status, and Rack Status.\u003c\/li\u003e\n\u003cli\u003eFlexible physical mounting infrastructure accommodates varied site layouts (System Face Mount, Rack Mount, Panel Mount, and Independent Mount).\u003c\/li\u003e\n\u003cli\u003eRobust design tailored for integration into highly demanding physical industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed machinery status visualization across large-scale industrial plant floors.\u003c\/li\u003e\n\u003cli\u003eCritical alarm event oversight and field-level troubleshooting on 3500 monitoring enclosures.\u003c\/li\u003e\n\u003cli\u003eLocalized parameter display for power generation steam\/gas turbines and large centrifugal compressors.\u003c\/li\u003e\n\u003cli\u003eControl panel integration for specialized marine, petrochemical, and oil and gas machinery skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3500\/93: System Display System\u003c\/li\u003e\n\u003cli\u003e135785-01: 3500\/93 Display Unit Spare\u003c\/li\u003e\n\u003cli\u003e137224-01: System Mount Assembly\u003c\/li\u003e\n\u003cli\u003e04344178: 10-32 x 0.37 Phillips pan head screw\u003c\/li\u003e\n\u003cli\u003e04309007: 4-40 x 0.62 Phillips pan head screw\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eProduct Component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eDisplay Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eDisplay Element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eLCD Module (Reflective version without backlight \/ Transflective version with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eUser Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eMembrane-switch Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eVisual Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eLCD Machine Parameter Display, Channel Status LEDs, New Alarm Event LED, Display Unit Status LED, Rack Status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eSupported Displays Per Rack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eUp to 2 System Displays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e-20 degC to 65 degC (-4 degF to 149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e-30 degC to 80 degC (-22 degF to 176 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eRadiated\/Conducted Emissions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eEN 55011, Class A (under EMC Directive EN 50081-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eElectrostatic Discharge Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eEN 61000-4-2, Criteria B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eRadiated Susceptibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eENV 50140, Criteria A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eElectrical Fast Transient Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eEN 61000-4-4, Criteria B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eSurge Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eEN 61000-4-5, Criteria B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eSafety Requirements Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003eEN 61010-01 (Low Voltage Directive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eConnector Pin \/ Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eD-Sub Interface Cable\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eInterconnects the 135785-01 Display Unit to the host 3500\/93 Display Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Restrictions:\u003c\/strong\u003e When choosing the System Face Mount configuration, the associated 3500\/93 Display Interface Module must be installed specifically in slot 15 of the 3500 rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility Check:\u003c\/strong\u003e Do not attempt to use the 3500\/93 System Face Mount options with a 3500\/05 or 3500\/05 A02 Mini-rack, as these physical configurations are incompatible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Assembly:\u003c\/strong\u003e Mount the Display Unit to the system mount assembly (137224-01) using exactly four 10-32 x 0.37 Phillips pan head screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Connection:\u003c\/strong\u003e Fasten the primary D-Sub interface cable securely to the rear panel of the Display Interface Module before closing the mount frame structures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Attachment:\u003c\/strong\u003e Open the frames of the system mount assembly at the pivoting points and attach them securely to the rack rails via four 4-40 x 0.62 Phillips pan head screws.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA-NRTL\/C Class I, Division 2, Groups A, B, C, D (T4 at Tamb = 65 degC)\u003c\/li\u003e\n\u003cli\u003eCE Mark\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 135785-01 component in a 3500\/93 setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is the external Display Unit that provides the physical LCD, status LEDs, and a keypad interface for machinery tracking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many system display units can be active on a single 3500 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA single 3500 monitoring system can support a maximum configuration of up to two 3500 System Displays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat types of visual notification LEDs are built into the front panel face?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe faceplate includes designated LEDs indicating Channel Status, New Alarm Events, Display Unit Status, and overall Rack Status.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary mounting arrangements for this display unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit can be implemented using System Face Mount, Rack Mount, Panel Mount, or Independent Mount configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there slot restrictions for the interface card when using a face mount assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, for a System Face Mount setup, the 3500\/93 Display Interface Module must be installed in slot 15 of the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I utilize the face mount configuration with a Bently Nevada mini-rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the 3500\/93 System Face Mount option is completely incompatible with the 3500\/05 and 3500\/05 A02 Mini-racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat hardware kit is required for executing a typical system face mount?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt requires a 137224-01 System Mount Assembly, four 10-32 x 0.37 screws, and four 4-40 x 0.62 screws.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable interface handles the link between the display and the interface module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe link is established through a dedicated D-Sub interface connection cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this item include the underlying backplane display interface module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the 135785-01 part number refers specifically to the Display Unit spare; interface cards must be sourced separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat environmental humidity parameters must be maintained during active operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe equipment must operate within a relative humidity limit of up to 95%, non-condensing.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519224683,"sku":"3500\/93 135785-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-93-135785-01-system-display-module-eiqsqsxutmd_212a7fbb-ea9f-46f6-ac6b-564cf4fb0157.jpg?v=1765440131","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-3500-93-135785-01-system-display-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}