{"product_id":"bently-nevada-81544-01-3300-transducer-input-output-and-recorder-terminal-module","title":"Module terminal d'entrée\/sortie et enregistreur pour transducteur Bently Nevada 81544-01 3300","description":"\u003cp\u003eThe \u003cstrong\u003e81544-01\u003c\/strong\u003e Transducer Input\/Output and Recorder Terminal Module, alternative factory part number \u003cstrong\u003e78462-02\u003c\/strong\u003e, is a rear-mounting interface component engineered exclusively for the Bently Nevada 3300\/45 Dual Differential Expansion Monitor within a Turbine Supervisory Instrumentation system. The module facilitates the dual-channel routing of dynamic signal inputs from two separate proximity probe transducer setups to evaluate absolute axial rotor displacement relative to the machine casing caused by thermal expansion during startup and shutdown. Electrically configured with a fixed input impedance of 10 kΩ, it supports the monitor's control logic which processes both the magnitude and direction of differential expansion across four programmable alert thresholds consisting of two over-alarm and two under-alarm setpoints. This passive terminal architecture is executed without onboard electromechanical relay contacts, operating instead as a direct signal pass-through and recorder distribution hub for continuous machinery protection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81544-01 (78462-02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Monitor Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/45 Dual Differential Expansion Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Independent channels (Channel B can be turned OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Interfacing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Proximity probe transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Capacity Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Setpoints total (2 Over-alarms, 2 Under-alarms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo onboard relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 10 kΩ input impedance is optimized to match the output parameter of standard Bently Nevada Proximitor sensors, ensuring zero signal degradation across the differential expansion measurement arc.\u003c\/li\u003e\n\u003cli\u003eWhen single-point axial measurements are required on smaller machine casings, Channel B must be programmatically disabled within the 3300\/45 monitor to suppress open-circuit gap voltage faults.\u003c\/li\u003e\n\u003cli\u003eBecause the 81544-01 contains no mechanical relays, all interlocking alarm and trip execution commands must be processed via the system backplane to an adjacent 3300 system relay module.\u003c\/li\u003e\n\u003cli\u003eThermal expansion changes during turbine ramp-up alter the baseline gap voltage; raw recorder outputs from this terminal map these proportional DC shifts for trend plotting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImplement rigorous shield grounding at the designated terminal strip block, ensuring the outer shield drain wire of the proximity probe extension cable is tied to instrument ground while remaining isolated at the sensor housing.\u003c\/li\u003e\n\u003cli\u003eMaintain separate wire routing paths for the low-impedance sensor inputs and any neighboring high-voltage AC control circuits to avoid cross-talk within the TSI panel enclosure.\u003c\/li\u003e\n\u003cli\u003ePrior to commissioning, verify that terminal lug screws are tightened to standard torque specifications to eliminate intermittent gap voltage fluctuations caused by physical contact resistance.\u003c\/li\u003e\n\u003cli\u003eEnsure proper spacing and mechanical alignment when sliding the 81544-01 terminal block onto the rear rack connectors to prevent pin distortion or open circuit paths on the 3300 backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 81544-01 terminal block module include mechanical relay contacts for driving local trip solenoids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the 81544-01 is designated as a No Relays module; it routes raw transducer and recorder signals, relying on the 3300 backplane to pass alarm states to a dedicated relay module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this component be utilized with any standard 3300 series proximity probe monitor, such as a radial vibration module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, this part number is mapped directly to the hardware parameters of the 3300\/45 Dual Differential Expansion Monitor and cannot be substituted into other monitoring slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the technical function of the alternate part number 78462-02 listed on the assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The number 78462-02 represents the bare raw board or sub-assembly designation used during production, which corresponds identically to the complete top-level part number 81544-01.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860306795,"sku":"81544-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-81544-01-xducr-i-o-and-record-terminals-phquym4p1wm_e2995e0f-7667-420e-acd8-3471ac8b1dcc.jpg?v=1765449280","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-81544-01-3300-transducer-input-output-and-recorder-terminal-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}