{"product_id":"bently-nevada-81724-00-08-10-02-non-contacting-proximity-probe-assembly","title":"Ensemble de sonde de proximité sans contact Bently Nevada 81724-00-08-10-02","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e81724-00-08-10-02\u003c\/strong\u003e is an industrial-grade, precision \u003cstrong\u003enon-contacting proximity probe assembly\u003c\/strong\u003e manufactured by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e for machine condition monitoring and asset protection. This high-integrity hardware transducer loop element operates on the eddy-current principle, generating a controlled radio-frequency field to track target behavior with micrometer-level resolution. The sensor dynamically reads displacement variations without physical mechanical contact, rendering immediate, high-fidelity data streams for tracking relative shaft vibration, fluid-film bearing oil clearance gaps, axial thrust position, and rotational speed variables on heavy-duty rotating machinery components.\u003c\/p\u003e\n\u003cp\u003eThe complete option string for the \u003cstrong\u003e81724-00-08-10-02\u003c\/strong\u003e explicitly designates its physical structure and mechanical layout limits. This specific variant features a standard unthreaded smooth body design combined with a 3\/8-24 UNF thread pattern configuration, an exact case length profile of 0.8 inches, an extended total loop cable length of 1.0 meter (approximately 3.3 feet), and a factory-fitted miniature coaxial connector end option. Built to withstand aggressive processing plant environments, the probe tip construction consists of high-stability polyphenylene sulfide (PPS) molded over a corrosion-resistant stainless steel main case, achieving a fully hermetic chemical and oil-splash barrier.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRugged non-contacting eddy-current transducer architecture capturing high-speed shaft dynamics without wear.\u003c\/li\u003e\n\u003cli\u003ePremium stainless steel case material integrated with a hermetically sealed polyphenylene sulfide (PPS) sensor tip.\u003c\/li\u003e\n\u003cli\u003ePrecise 3\/8-24 UNF thread pattern configuration designed for clean insertion into localized bearing housings.\u003c\/li\u003e\n\u003cli\u003eSpecialized factory-terminated miniature coaxial connector establishing low-loss coupling with extension cables.\u003c\/li\u003e\n\u003cli\u003eRobust internal winding compensation maintaining high linear scale factor stability across wide temperature bounds.\u003c\/li\u003e\n\u003cli\u003eUniversal compatibility with matching proximity sensor conditioners and 3500 series protection racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy radial shaft vibration tracking and relative fluid-bearing position diagnostics on high-speed industrial fans.\u003c\/li\u003e\n\u003cli\u003eContinuous axial rotor position measurements and thrust displacement safety logging inside heavy-duty process pumps.\u003c\/li\u003e\n\u003cli\u003eHigh-integrity zero-speed tracking, tachometer signal acquisition, and Keyphasor phase reference indexing across balance-of-plant machinery skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81724 (Proximity Probe Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Option Suffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e81724-00-08-10-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00 (0.0 in unthreaded smooth length configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-08 (0.8 in total physical threaded case length profile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 (1.0 meter \/ 3.3 feet integrated trailing lead length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-02 (Miniature coaxial connector assembly end termination)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%; height: 529.031px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 33.3756%; height: 19.5938px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 63.291%; height: 19.5938px;\"\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 19.5938px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 19.5938px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 19.5938px;\"\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 19.5938px;\"\u003e81724-00-08-10-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 19.5938px;\"\u003eNon-Contacting Proximity Probe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003eRadio-frequency eddy-current impedance analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eThread Profile Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003e3\/8-24 UNF standard thread structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eUnthreaded Base Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003e0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eThreaded Body Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003e0.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eIntegrated Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 19.5938px;\"\u003e\u003cstrong\u003eConnector Variant Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 19.5938px;\"\u003eMiniature coaxial male connection point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eCase Construction Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003eAISI 303 or 304 stainless steel body profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eProbe Tip Material Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003eHigh-performance polyphenylene sulfide (PPS) polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eLinear Scale Calibration Target\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003eTypically optimized for AISI 4140 steel target materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003eStandard high-performance industrial envelope for severe fluid exposure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eRelative Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003eMinimum tracking limits required due to flexible coaxial shield layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3756%; height: 39.1875px;\"\u003e\u003cstrong\u003eAverage Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 63.291%; height: 39.1875px;\"\u003eIndustrial standard proximity field probe package weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTermination Point\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial Male Tip Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-loss miniature gold-plated terminal interface linking to the main extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThreaded External Body\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRigid mechanical mounting engagement interface for machine casing indicator blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThreaded Casing Mounting:\u003c\/strong\u003e Thread the probe assembly directly into the pre-drilled machine case port or bracket layout. Use a calibrated torque tool to secure the locknuts according to specified parameters to prevent thread stripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Probe Gap Adjustment:\u003c\/strong\u003e Use a digital voltmeter connected to the proximity signal conditioner block to monitor the output gap voltage while threading the body. Adjust until the specified static voltage bias (typically matching the midpoint of the linear scale) is locked in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Connector Insulation:\u003c\/strong\u003e Thread the miniature coaxial terminal connection firmly onto the matching extension cable link. Apply specialized self-fusing insulation sleeves or connector protectors over the connection point to isolate the bare metal casing from structural machinery ground lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing Security:\u003c\/strong\u003e Route the integrated 1.0-meter trailing lead wire inside a dedicated flexible metal conduit run. Keep all proximity signal lines isolated from high-voltage AC motor power runs to eliminate capacitive electrical noise cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852311403,"sku":"81724-00-08-10-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-81724-00-08-10-02-proximity-probe-ljlma0gwwuw_aae6255f-265f-4dea-a6ba-30466ef69559.jpg?v=1765449079","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-81724-00-08-10-02-non-contacting-proximity-probe-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}