{"product_id":"bently-nevada-89477-30-interconnect-cable","title":"Câble d'interconnexion Bently Nevada 89477-30","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e89477-30\u003c\/strong\u003e is a heavy-duty, industrial-grade \u003cstrong\u003estandard interconnect cable\u003c\/strong\u003e engineered to maintain high-integrity signal routes inside machine monitoring environments. This specialized electrical link is designed to transmit critical, raw velocity waveforms and high-frequency acceleration variables from casing-mounted sensors or field transmitters straight to centralized monitor frameworks, programmable logic controllers (PLCs), or distributed control systems (DCSs). The \u003cstrong\u003e89477-30\u003c\/strong\u003e utilizes a twisted, shielded pair architecture wrapped in a robust, chemically stable outer insulation jacket to deliver excellent mitigation against high-frequency electromagnetic interference (EMI) and radio frequency interference (RFI) common around heavy industrial machinery arrays.\u003c\/p\u003e\n\u003cp\u003eThe assembly comes factory-terminated with a tight-fitting, weather-resistant molded female connector block at one end to establish a secure environmental seal on the sensor header, and raw bare wire terminal ends on the opposing side for quick landing onto local panel terminal strips. The \u003cstrong\u003e-30\u003c\/strong\u003e suffix indicates a precise factory-cut length configuration of exactly 30 feet (approximately 9.1 meters). Built to operate continuously under wide temperature variations, it ensures highly reliable data delivery for critical rotating assets without adding signal distortion or capacitive loss.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density twisted, shielded pair wire configuration to block aggressive industrial electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eFactory-molded moisture-resistant female terminal connector establishing a reliable ambient seal at the transducer head.\u003c\/li\u003e\n\u003cli\u003eStripped bare wire trailing ends for efficient termination inside local junction boxes or machine monitoring racks.\u003c\/li\u003e\n\u003cli\u003eTough, corrosion-resistant outer insulation layer designed to withstand oil splash and physical friction forces.\u003c\/li\u003e\n\u003cli\u003eOptimized electrical parameters preventing capacitive signal attenuation across extended structural measurement spans.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInterfacing casing-mounted piezo-velocity sensors or accelerometers with remote monitoring racks.\u003c\/li\u003e\n\u003cli\u003eRouting dynamic diagnostic asset protection signals from hazardous field areas to safe control rooms.\u003c\/li\u003e\n\u003cli\u003eGeneral low-voltage instrumentation link integration across high-vibration balance-of-plant rotating machinery skids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477 (Standard Interconnect Cable Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Assembly Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 (Specified length of 30 feet \/ 9.14 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89477-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Twisted Shielded Interconnect Cable Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Wire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial instrumentation gauge layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwisted pair with integrated shield drain wire line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-coverage aluminum-polyester or equivalent braid shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded moisture-resistant female socket connector block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor End Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBare wire ends prepared for terminal strip landing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Jacket Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRuggedized chemical and wear-resistant polymer outer sheath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial performance envelope rated for high-thermal field exposures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 ft. (9.14 m) fixed option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Installation Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible routing layout design compatible with standard conduit bends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Weight Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard field interconnect cable weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable End Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePhysical Interface Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Transducer Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded female terminal connector with integrated threaded locking ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitor Panel Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparate bare wire channels for positive, negative, and shield drain lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Path Planning:\u003c\/strong\u003e Route the interconnect cable through dedicated low-voltage instrument conduits. Keep the signal run isolated from parallel high-voltage motor supply lines to minimize capacitive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Connection Sealing:\u003c\/strong\u003e Align the female terminal connector pins accurately onto the transducer plug. Hand-tighten the threaded coupling ring completely to verify a locked, moisture-resistant environmental barrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Compliance:\u003c\/strong\u003e Maintain generous layout bend loops at all enclosure entry joints. Avoid sharp crimps or tight physical kinks that could break the internal core layout or split the shielding layer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Point Grounding:\u003c\/strong\u003e Connect the shield drain wire only at one designated common reference ground point—typically at the monitor panel terminal strip—to prevent creating performance-degrading ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666735427947,"sku":"89477-30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-89477-30-interconnect-cable-bam1fedghr3_b914bd85-71f7-4d98-862c-742ab51d7f4b.jpg?v=1765446779","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-89477-30-interconnect-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}