{"product_id":"bently-nevada-9200-03-05-10-00-9200-series-seismoprobe-velocity-transducer","title":"Transducteur de vitesse sismoprobe série 9200 Bently Nevada 9200-03-05-10-00","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e9200-03-05-10-00\u003c\/strong\u003e is a 2-wire moving-coil velocity transducer engineered for the absolute vibration measurement of casing structures, bearing housings, or structural components. Operating on a self-generating electrodynamic principle, this \u003cstrong\u003e9200-03-05-10-00\u003c\/strong\u003e seismoprobe transforms mechanical velocity into a proportional voltage signal without requiring external excitation power. Its moving-coil design delivers robust resistance against false trips or signal degradation typically induced by impact, shock, or impulsive excitation near reciprocating or heavy rotating equipment. The transducer features a top-mounted terminal block interface for field electrical termination and mounts onto flat machine surfaces via a threaded stud, allowing direct integration into machinery protection systems, distributed control systems (DCS), or plant asset management monitors.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrodynamic moving-coil architecture providing high immunity to false trips caused by shock or high-frequency impact.\u003c\/li\u003e\n\u003cli\u003ePassive, self-generating design eliminates the need for external loop or module power supplies.\u003c\/li\u003e\n\u003cli\u003e2-wire electrical connectivity for straightforward field wiring and long-distance signal transmission.\u003c\/li\u003e\n\u003cli\u003eTop-mounted terminal block layout facilitates flexible configuration of regional field cables.\u003c\/li\u003e\n\u003cli\u003eRugged construction designed to maintain measurement fidelity under continuous machinery case vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHorizontal vibration monitoring on large industrial pumps and fans.\u003c\/li\u003e\n\u003cli\u003eBearing housing casing velocity measurements on steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eStructural monitoring of gearbox casings and support frames.\u003c\/li\u003e\n\u003cli\u003eCasing vibration tracking on industrial motors, generators, and blowers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Series: 9200 Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Angle Option: Horizontal (90 degrees +-2.5 degrees), 4.5 Hz minimum operating frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration Option: Top-mount terminal block electrical connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: M10x1 threaded mounting stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprovals Option: No hazardous area certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-03-05-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoving-Coil Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive electrodynamic (self-generating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) +-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 1,000 Hz (+0 dB, -3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 degC to +121 degC (-20 degF to +250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal (90 degrees +-2.5 degrees)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 mm (4 in) typical (depending on connector option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41 mm (1.6 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Mounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.41 Nm (12.5 in lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Block Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Signal Output (Velocity Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Signal Output (Signal Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Preparation:\u003c\/strong\u003e Prepare a flat, clean, and smooth surface on the machine bearing housing or casing. Ensure the area is free of rust, paint, or grease to guarantee proper mechanical transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Threading:\u003c\/strong\u003e Secure the transducer tightly to the prepared surface utilizing the M10x1 threaded mounting stud. Tighten the base mounting stud to a torque specification of 5.6 Nm (50 in lb). Adhere strictly to this limit to prevent casing distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Verification:\u003c\/strong\u003e Align the transmitter strictly for horizontal operation (90 degrees +-2.5 degrees from vertical). Misalignment outside this window alters internal suspension physics and leads to severe measurement errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e When attaching field wiring components, tighten the connector terminals to a specification of 1.41 Nm (12.5 in lb) to establish secure electrical contact without damaging the hardware threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Selection:\u003c\/strong\u003e Use a high-quality, twisted 2-conductor shielded instrument cable to run signals from the top terminal block to the instrumentation rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect the cable shield wire cleanly to the instrumentation or monitor ground at the control room end only. Insulate the shield wire at the transducer terminal box to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpact Prevention:\u003c\/strong\u003e Avoid hitting or dropping the transducer housing during installation procedures to safeguard the internal moving-coil mechanism from structural deformation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864140651,"sku":"9200-03-05-10-00 Transducer","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-03-05-10-00-transducer-ijg1gb5zujl_0d2232c9-47af-4f9b-9832-a31333d0d0bf.jpg?v=1765449391","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-9200-03-05-10-00-9200-series-seismoprobe-velocity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}