{"product_id":"bently-nevada-9200-06-05-05-00-seismoprobe-velocity-transducer","title":"Transducteur de vitesse Seismoprobe Bently Nevada 9200-06-05-05-00","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9200-06-05-05-00\u003c\/strong\u003e is a two-wire \u003cstrong\u003evelocity transducer\u003c\/strong\u003e designed for continuous monitoring or periodic diagnostics of absolute casing, bearing housing, or structural vibration. Utilizing moving-coil technology, this instrument generates a voltage output directly proportional to the transducer's vibration velocity without requiring external operating power. The unique mechanical architecture of the \u003cstrong\u003e9200-06-05-05-00\u003c\/strong\u003e ensures low sensitivity to impact or impulsive excitation, delivering highly reliable and repeatable dynamic data on critical machinery such as turbines, pumps, and industrial fans.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMoving-coil technology provides a direct voltage output without the need for external power.\u003c\/li\u003e\n\u003cli\u003eLow sensitivity to impact or impulsive excitation compared to solid-state alternatives.\u003c\/li\u003e\n\u003cli\u003eTwo-wire engineering supports both permanent machinery protection and portable field measurements.\u003c\/li\u003e\n\u003cli\u003eDurable anodized aluminum case construction for survival in aggressive industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAbsolute bearing housing and machinery casing vibration measurements.\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbine casing monitoring protocols.\u003c\/li\u003e\n\u003cli\u003ePeriodic data collection using portable test and diagnostic equipment.\u003c\/li\u003e\n\u003cli\u003eStructural vibration analysis on large-scale balance-of-plant equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFactory Configuration Profile\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e9200\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-wire Seismoprobe Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-06\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Mounting Angle\/Minimum Operating Frequency: 0 ±100, 10 Hz (600 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector Option: Terminal block top mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Base Option: No base; 1\/2-in 20 UNF-3A stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: No approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9200-06-05-05-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Velocity Seismoprobe Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mV\/mm\/s (500 mV\/in\/s) ±5% at +22 Celsius (+72 Fahrenheit) with 25 mm\/s (1 in\/s) vibration at 100 Hz into a 10 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1 kHz (60,000 cpm); +0, -3dB typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ±100 (Vertical, viewed from driver end)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDynamic Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.54 mm (0.100 in) peak-to-peak maximum displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithstands 50 g peak maximum acceleration along non-sensitive axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Leadwire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1,000 feet) between transducer and 3300 or 3500 Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating\/Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-29 Celsius to +121 Celsius (-20 Fahrenheit to +250 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum A204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGasket Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide with nickel-plated copper contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Base Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo base; 1\/2-in 20 UNF-3A stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 Nm (50 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78.54 mm (3.092 in) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.40 mm (1.63 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 grams (10.5 ounces) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Terminal\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Output (Pin A goes positive with respect to Pin B when case velocity is toward connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrientation Alignment:\u003c\/strong\u003e The transducer must be physically mounted within its designated 0 ±100 vertical limits relative to the calibration angle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Rating:\u003c\/strong\u003e Tighten the integrated 1\/2-in 20 UNF-3A mounting thread to exactly 5.6 Nm (50 in-lb) to guarantee optimal frequency transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Path:\u003c\/strong\u003e Ensure the chosen structural interface point faithfully transmits internal rotor malfunctions to the external casing where the transducer sits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e Verify that the top terminal block connector is fully buttoned up and sealed against regional dust and moisture entry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 05 mounting base configuration indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe -05 code indicates that the transducer is supplied with no separate circular or rectangular flange base; instead, it features an integrated 1\/2-in 20 UNF-3A threaded stud directly on the bottom for mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum operating frequency limits of this velocity sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model incorporates the -06 frequency option, establishing a low-end frequency limit of 10 Hz (600 cpm) before signal attenuation starts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the moving-coil principle benefit this transducer over standard accelerometers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause it utilizes moving-coil technology rather than solid-state integration crystals, it is substantially more resilient and less sensitive to mechanical impacts or abrupt impulsive shocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs an external power supply or charge amplifier required for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this two-wire velocity system is entirely self-generating and creates a direct voltage output signal from the internal coil movement, making it highly versatile for portable and diagnostic tasks.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666853720427,"sku":"9200-06-05-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9200-06-05-05-00-velocity-seismoprobe-w514jt2zgqz_3f2acb0a-f4fb-455f-8d51-77fd859d0a50.jpg?v=1765449119","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-9200-06-05-05-00-seismoprobe-velocity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}