{"product_id":"bently-nevada-9571-50-standard-interconnect-cable","title":"Câble d'interconnexion standard Bently Nevada 9571-50","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 9571-50\u003c\/strong\u003e is a standard interconnect cable designed for use with industrial vibration monitoring and transducer systems. The cable assembly includes a moisture-resistant female connector at the transducer end and ring lugs at the monitor end for direct field wiring termination.\u003c\/p\u003e\n\u003cp\u003eThe cable uses shielded 0.382 mm2 (22 AWG) conductors to support stable signal transmission in electrically noisy industrial environments. The shielding construction assists with EMI\/RFI mitigation in machinery monitoring installations.\u003c\/p\u003e\n\u003cp\u003eThis interconnect cable is intended for connection between vibration transducers and monitoring equipment in rotating machinery applications including turbines, pumps, compressors, motors, and general condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe assembly supports installation in industrial environments requiring moisture resistance and extended operating temperature capability.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eShielded 0.382 mm2 (22 AWG) cable\u003c\/li\u003e\n\u003cli\u003eMoisture-resistant female connector\u003c\/li\u003e\n\u003cli\u003eRing lug termination at monitor end\u003c\/li\u003e\n\u003cli\u003eIndustrial transducer interconnect design\u003c\/li\u003e\n\u003cli\u003eEMI\/RFI shielding support\u003c\/li\u003e\n\u003cli\u003eFlexible field installation\u003c\/li\u003e\n\u003cli\u003eExtended temperature range\u003c\/li\u003e\n\u003cli\u003eCompatible with vibration monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVibration monitoring systems\u003c\/li\u003e\n\u003cli\u003eProximity transducer connections\u003c\/li\u003e\n\u003cli\u003eMachinery protection systems\u003c\/li\u003e\n\u003cli\u003eTurbine monitoring installations\u003c\/li\u003e\n\u003cli\u003eCompressor monitoring systems\u003c\/li\u003e\n\u003cli\u003eMotor condition monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial rotating equipment\u003c\/li\u003e\n\u003cli\u003eProcess plant instrumentation\u003c\/li\u003e\n\u003cli\u003ePredictive maintenance systems\u003c\/li\u003e\n\u003cli\u003ePermanent mounted monitoring installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e9571-AA: Standard Interconnect Cable\u003c\/li\u003e\n\u003cli\u003e-50: 50 ft (15.2 m) cable length option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eElectricalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eCable Type\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eShielded cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eConductor Size\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eEnvironmentalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e-29 to 121 degC (-20 to 250 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMoisture Resistance\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eMoisture-resistant connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eMechanicalSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eFemale connector at transducer end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eMonitor End Termination\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eRing lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eMinimum Length\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e2 ft (0.60 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eMaximum Length\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e99 ft (30 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eGeneralSpecification\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eStandard Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eTransducer Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eConnections\/Interfaces\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003eConnector PinFunction\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eFemale Connector\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eTransducer connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eRing Lugs\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eMonitor termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cp\u003eRoute the cable separately from high-voltage motor wiring and variable frequency drive output cables to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eMaintain cable shielding continuity throughout the installation to support signal integrity.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive cable bending near the connector termination points during installation.\u003c\/p\u003e\n\u003cp\u003eSecure the cable properly to minimize vibration-related mechanical stress.\u003c\/p\u003e\n\u003cp\u003eVerify ring lug tightening torque during monitor termination work.\u003c\/p\u003e\n\u003cp\u003eInspect connector sealing surfaces before installation in moisture-prone environments.\u003c\/p\u003e\n\u003cp\u003eUse appropriate cable routing practices to prevent abrasion or pinch damage.\u003c\/p\u003e\n\u003cp\u003eAvoid extending the cable beyond the specified maximum length.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the conductor size of this cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cable uses 0.382 mm2 (22 AWG) conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of shielding is provided?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe assembly uses shielded cable construction for industrial signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat connector is installed at the transducer end?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA moisture-resistant female connector is installed at the transducer end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the monitor end terminated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor end uses ring lug terminations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum supported cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum specified length is 99 ft (30 m).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum available cable length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe minimum specified length is 2 ft (0.60 m).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the cable be used in industrial environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The cable is intended for industrial vibration monitoring installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the cable support EMI\/RFI mitigation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe shielded construction assists with EMI\/RFI reduction.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat systems is the cable intended for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is intended for transducer and vibration monitoring system connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the cable be used outdoors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe connector is moisture resistant, but installation suitability depends on enclosure and site conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat temperature range is supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified operating range is -29 to 121 degC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cable suitable for permanent installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is suitable for permanently mounted machinery monitoring systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666624344427,"sku":"9571-50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-50-standard-interconnect-cable-tfd2n403jen_f9932837-544b-41d4-9e0b-edfee3645b51.jpg?v=1765444312","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-9571-50-standard-interconnect-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}