{"product_id":"bently-nevada-990-05-xx-01-cn-mod-165335-01-990-vibration-transmitter","title":"Bently Nevada 990-05-XX-01-CN MOD : 165335-01 | Transmetteur de vibration 990","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e990-05-XX-01-CN MOD: 165335-01\u003c\/strong\u003e is a high-reliability, two-wire \u003cstrong\u003e990 Vibration Transmitter\u003c\/strong\u003e engineered by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e to supply continuous machinery protection monitoring directly to plant control networks. This industrial component integrates the processing circuitry of a standard proximity sensor into a compact field-mount transmitter package. It accepts inputs from a non-contacting 3300 XL 8mm eddy-current proximity probe and extension cable, processing raw high-frequency micro-gap changes into a linear, proportional 4 to 20 mA current output loop. This analog signal interfaces directly with standard Distributed Control Systems (DCS), Programmable Logic Controllers (PLC), or simple process data recorders without requiring a separate rack system monitor.\u003c\/p\u003e\n\u003cp\u003eThis precise hardware configuration features a factory-calibrated \u003cstrong\u003efull-scale measurement option of 0-5 mils pp (0-125 um pp)\u003c\/strong\u003e, designed for direct tracking of radial shaft vibration amplitudes. The physical casing comes integrated with \u003cstrong\u003e35 mm DIN rail clips\u003c\/strong\u003e to allow fast, secure snap-on mounting into field marshalling junctions. This variant is engineered with the \u003cstrong\u003eCN agency option\u003c\/strong\u003e, which provides global and local industrial compliance covering ATEX\/IECEx and Chinese NEPSI hazardous area safety certifications. The assignment \u003cstrong\u003eMOD: 165335-01\u003c\/strong\u003e designates a specialized factory modification code that ensures specific internal processing tweaks or precise component matching parameters tailored to targeted machinery requirements while preserving full base-model compatibility.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-wire loop-powered architecture providing direct 4 to 20 mA analog output integration into host PLC or DCS loops.\u003c\/li\u003e\n\u003cli\u003eFactory-calibrated full-scale range measuring 0-5 mils peak-to-peak (0-125 um peak-to-peak) for high-accuracy shaft vibration logging.\u003c\/li\u003e\n\u003cli\u003eIntegral 35 mm DIN rail mounting clips allowing rapid, toolless snap-fit structural deployment on enclosure racks.\u003c\/li\u003e\n\u003cli\u003eRobust hazardous area safety design certified with combined ATEX\/IECEx and local Chinese NEPSI industrial markings.\u003c\/li\u003e\n\u003cli\u003eDedicated factory configuration label designated under MOD: 165335-01 for precise system architecture synchronization.\u003c\/li\u003e\n\u003cli\u003eOnboard BNC buffered output connector providing unconditioned dynamic eddy-current waveforms for local machinery diagnostics.\u003c\/li\u003e\n\u003cli\u003eBuilt-in non-interacting zero and span adjustments allowing clean precision calibration touch-ups under field conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect radial vibration tracking on fluid-filmed bearings of industrial centrifugal air compressors and process fans.\u003c\/li\u003e\n\u003cli\u003eContinuous asset health processing loop monitoring on medium-sized balance-of-plant electric motor or pump skids.\u003c\/li\u003e\n\u003cli\u003eDistributed, standalone field instrumentation integration on specialized gas or water utility infrastructure pumps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOption String Breakdown\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003e990 Vibration Transmitter Product Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Full-scale Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003e0-5 mils peak-to-peak (0-125 um peak-to-peak) measurement scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: System Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-XX\u003c\/td\u003e\n\u003ctd\u003eConfigurable system loop length option (Matches probe\/cable design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Mounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-CN\u003c\/td\u003e\n\u003ctd\u003eCombined ATEX\/IECEx and Chinese NEPSI hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModification Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMOD: 165335-01\u003c\/td\u003e\n\u003ctd\u003eSpecialized factory configuration modification designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-01-CN MOD: 165335-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-Wire Proximity Vibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Scale Linear Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mils pp (0 to 125 um pp) peak-to-peak displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signaling Loop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear 4 to 20 mAdc proportional current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kohm nominal (Protected against continuous short circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffered Output Scale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal 7.87 V\/mm (200 mV\/mil) corresponding to the probe gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12 Vdc to +35 Vdc loop power required at the terminal links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Core Matching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibrated for 3300 XL 8mm proximity probe and extension cable loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Connector Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePin terminals accepting wire cross-sections up to 1.5 mm squares\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Framework Build\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate body structure with integrated aluminum mounting plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.43 kg (0.9 lbm) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Index\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% maximum, non-condensing exposure boundaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROBE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial port linking to the incoming proximity transducer extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+ (SIG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive loop terminal interface receiving incoming +12 to +35 Vdc power inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e- (COM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNegative loop connection returning the regulated 4 to 20 mA measurement signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBUF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated front coaxial BNC socket providing unconditioned voltage waveforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Alignment:\u003c\/strong\u003e Position the transmitter housing directly over standard 35 mm DIN rail tracking. Apply firm downward pressure until the integrated plastic clips snap tightly over the rail flanges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Frame Isolation:\u003c\/strong\u003e Ensure the internal ground planes remain isolated from bare electrical conduit paths. The transmitter plate must remain isolated from structural rack frames to eliminate low-voltage ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length Verification:\u003c\/strong\u003e Verify that the system length option (Option -XX) perfectly matches the combined physical length of the connected 3300 XL 8mm probe and extension cable to maintain proper scaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Signal Diagnostic Check:\u003c\/strong\u003e Use the front-facing coaxial BNC connector to patch into local signal analyzers. This buffered port provides a raw voltage wave (200 mV\/mil) without altering the primary 4-20 mA control loop tracking.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666849034603,"sku":"990-05-XX-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-990-05-xx-01-cn-vibration-transmitter-e1zi1lxp55q_5212f2cd-b252-4be2-9040-fdde7be189e4.jpg?v=1765449005","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-990-05-xx-01-cn-mod-165335-01-990-vibration-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}