{"product_id":"bently-nevada-aap1407030-00100-3300-xl-nsv-proximity-transducer-probe","title":"Sonde de transducteur de proximité NSv 3300 XL Bently Nevada AAP1407030-00100","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada AAP1407030-00100\u003c\/strong\u003e (interchangeable with factory cross-reference code \u003cstrong\u003e109548-01 P1407030-00100\u003c\/strong\u003e) is a specialized, non-contact eddy-current eddy-current proximity probe sensor belonging to the high-density \u003cstrong\u003e3300 XL NSv\u003c\/strong\u003e (Narrow Side View) Series. Engineered specifically for industrial fluid-film bearing machinery with extremely tight installation spaces, it delivers an optimized radiation footprint to mitigate counterbore, side-view, or rear-view physical restrictions. The probe operates by generating a high-frequency electromagnetic field that measures static gap voltage displacements and dynamic vibration frequencies, transferring accurate shaft position signals to a paired 3300 XL NSv Proximitor Sensor. It is primarily deployed on small-diameter rotating assemblies such as centrifugal air compressors, refrigeration chillers, and process gas turbo-compressors where conventional 5 mm or 8 mm sensor tips encounter structural interference or scale factor distortion from confined housing walls.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eTransducer Subsystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eEddy-current non-contact proximity probe sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eTarget Material Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eAISI 4140 steel (standard calibration target)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eLinear Sensing Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eLinear Range Boundaries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e0.25 mm to 1.75 mm (10 mils to 70 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eNominal Voltage Output Span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eApproximate linear voltage span from -1 VDC to -13 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% over ambient limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eDeviation From Best Fit Straight Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eLess than ±0.06 mm (±2.3 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eRecommended Operational Gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eMinimum Shaft Target Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e30 mm (1.2 in) for standard radial X-Y configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eMinimum Flat Target Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e8.9 mm (0.35 in); 13 mm (0.5 in) recommended minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eProbe Tip Base Encapsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003ePolyphenylene sulfide (PPS) engineering thermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eProbe Case Material Housing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eConnector Interface Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eGold-plated brass coaxial ClickLoc miniature connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eInternal Pressure Seal Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eIntegrated Viton O-ring for differential casing containment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e-34 °C to +177 °C (-30 °F to +351 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eStorage Temperature Profile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e-52 °C to +105 °C (-62 °F to +221 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003cstrong\u003eOperational Altitude Max Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003cstrong\u003eNet Item Component Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e0.10 kg (0.22 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale Factor Stability:\u003c\/strong\u003e For optimal eddy-current scaling, the target face must be flat and symmetric. If measuring on shaft diameters smaller than 30 mm (1.2 in) or flat profiles under 13 mm (0.5 in), reduction of the baseline gap voltage down towards the lower limit of the linear window may be necessary to correct for boundary attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSide-View Clearance:\u003c\/strong\u003e The specialized configuration allows this probe to withstand close proximity to adjacent metallic structures. However, cross-talk or field distortions can occur if the clear side-view path dips below the structural limits of the machine's counterbore geometry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterchangeability Rules:\u003c\/strong\u003e The probe must be paired exclusively with a 3300 XL NSv Proximitor Sensor and its corresponding 3300 NSv extension cable. Total electrical length configuration must be verified to prevent impedance mismatches across the channel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Terminal Torque:\u003c\/strong\u003e Hand-tighten the gold-plated coaxial connectors until a physical, tactile \"click\" is felt. Never apply pliers or wrenches to the miniature joints, as over-torqueing can fracture the internal center pin conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Protection Measures:\u003c\/strong\u003e Use the factory-supplied silicone self-fusing tape to wrap outer connector couplings exposed to moisture or particulate contamination. Avoid deploying silicone wrapping sections within the internal machinery casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBending Radius Demands:\u003c\/strong\u003e Maintain a minimum structural bending radius of 25.4 mm (1.0 in) for standard probe leads and armored extensions to prevent macro-bending fractures within the internal coax core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Procurement FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How does the AAP1407030-00100 model manage differential pressure inside process compressor casings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The sensor case features a dedicated internal Viton O-ring pressure configuration. This barrier acts as a mechanical seal to isolate differential process gases from migrating up the internal probe core and into outer terminal junction boxes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What is the main differentiator between this NSv series probe and standard Bently Nevada 8 mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The NSv series utilizes a highly narrowed electromagnetic sensing footprint. This allows it to accurate track radial vibration on miniature targets down to 8.9 mm in diameter where standard 8 mm probes would face extreme eddy-current side-loading errors from the machine walls.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Is bench calibration or matched trimming mandatory when swapping out this sensor head?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: No. The product is manufactured to meet precise factory tolerance baselines, enabling complete structural interchangeability. Components can be swapped directly in the field without requiring bench recalibration or parameter scaling adjustments at the main machinery monitor rack.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666611302763,"sku":"AAP1407030-00100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-aap1407030-00100-3300-xl-nsv-proximity-probe-d2meg0vkew2_586c6fc7-077f-4ccd-8eff-2a34f90b719e.jpg?v=1765444143","url":"https:\/\/www.plcprotech.com\/fr\/products\/bently-nevada-aap1407030-00100-3300-xl-nsv-proximity-transducer-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}