{"product_id":"cc-taox11-honeywell-experion-c300-analog-output-iota-16-channel","title":"CC-TAOX11 | Honeywell | Experion C300 Sortie analogique IOTA (16 canaux)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cstrong\u003e CC-TAOX11 \u003c\/strong\u003eis a high-density \u003cspan\u003eAnalog Output Field Termination Assembly (IOTA)\u003c\/span\u003e module designed for the \u003cspan\u003eHoneywell Experion C300\u003c\/span\u003e controller platform. This module serves as the physical interface for \u003cspan\u003e16 independent channels\u003c\/span\u003e, delivering a standardized \u003cspan\u003e4-20 mA\u003c\/span\u003e signal to field-side control elements such as valve positioners, variable speed drives, and actuators. Engineered for high-availability process environments, the \u003cspan\u003eCC-TAOX11\u003c\/span\u003e is widely deployed in \u003cspan\u003eoil and gas processing, large-scale power generation, and chemical manufacturing\u003c\/span\u003e. Its primary function is to convert digital control commands from the C300 processor into precise analog currents, ensuring deterministic control of critical loops while maintaining low signal noise and high thermal stability.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Technical Parameter Matrix\u003c\/h3\u003e\n\u003cp\u003eThe following table encapsulates the essential electrical and mechanical specifications for the \u003cspan\u003eCC-TAOX11\u003c\/span\u003e to support engineering design and cabinet layout planning.\u003c\/p\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eTechnical Parameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCC-TAOX11\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion C300 \/ Series C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA (DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Density\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Ripple\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 100 mV p-p (at power line frequency)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Ohm (Standard Reference)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating (Standard for Series C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompression or Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Redundant I\/O Configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries C I\/O Termination Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Performance \u0026amp; Application FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eDoes the CC-TAOX11 support redundant configurations?\u003c\/span\u003eYes. As a Series C IOTA, the \u003cspan\u003eCC-TAOX11\u003c\/span\u003e is designed to support redundant I\/O module pairs. In a redundant setup, if one Analog Output module fails, the second module maintains the \u003cspan\u003e4-20 mA\u003c\/span\u003e signal to the field without any bump in the process, ensuring continuous plant operation.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHow does the 100 mV peak-to-peak ripple specification affect performance?\u003c\/span\u003eThe low ripple content (\u003cspan\u003e\u0026lt; 100 mV p-p\u003c\/span\u003e) ensures that the control signal is \"clean.\" This is particularly important for sensitive smart positioners or actuators that might misinterpret signal noise as a control command, which could otherwise lead to \"hunting\" or premature wear of mechanical components.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIs this module suitable for corrosive environments?\u003c\/span\u003eYes. The \u003cspan\u003eCC-TAOX11\u003c\/span\u003e typically features conformal coating as part of the Series C hardware standard. This provides superior protection against humidity, salt spray, and corrosive gases (such as H2S or SO2), making it ideal for offshore platforms and wastewater treatment facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Deployment \u0026amp; Field Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTermination and Wiring:\u003c\/span\u003e When connecting field wiring to the \u003cspan\u003e16 channels\u003c\/span\u003e, ensure that high-quality twisted-pair shielded cable is used. The shield should be grounded at the IOTA end to minimize electromagnetic interference. The compression terminals are designed for ease of use, but ensure that no stray wire strands cause short circuits between adjacent channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLoad Impedance Verification:\u003c\/span\u003e The module is optimized for a \u003cspan\u003e250 Ohm\u003c\/span\u003e load. Before commissioning, verify the total loop resistance (including the field device and wire resistance). If the impedance is significantly outside the specified range, it may lead to current saturation or drive capability issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundancy Linkage:\u003c\/span\u003e When installing for a redundant application, ensure the redundancy cable is properly seated between the primary and secondary I\/O modules. The \u003cspan\u003eCC-TAOX11\u003c\/span\u003e IOTA provides the physical infrastructure to bridge these signals seamlessly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Superiority \u0026amp; System Resilience\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell CC-TAOX11\u003c\/span\u003e represents the gold standard in high-density analog control. By consolidating \u003cspan\u003e16 channels\u003c\/span\u003e into a single Series C footprint, it significantly reduces cabinet space requirements and simplifies field wiring architecture. As an \u003cspan\u003eOriginal and New\u003c\/span\u003e component, it utilizes advanced diagnostic circuitry that can detect open circuits or shorted field loops, reporting these faults directly to the Experion HMI. This proactive diagnostic capability, combined with the module's robust electrical isolation and low power dissipation, makes the \u003cspan\u003eCC-TAOX11\u003c\/span\u003e a highly reliable asset for maintaining the peak efficiency of complex industrial control strategies.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705775190379,"sku":"CC-TAOX11","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-TAOX11-1yr1kjm1j31_67d5a8ad-f940-4b64-bd13-ccf4f4e7a300.jpg?v=1766659648","url":"https:\/\/www.plcprotech.com\/fr\/products\/cc-taox11-honeywell-experion-c300-analog-output-iota-16-channel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}