{"product_id":"cp1e-n60dr-d-omron-cp1e-cpu-unit-hardware","title":"Unité matérielle CPU CP1E Omron CP1E-N60DR-D","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Omron CP1E-N60DR-D is an all-in-one programmable logic controller (PLC) package designed for small-scale machinery and process automation applications. Operating as the core controller, it processes sequence logic and interfaces directly with field equipment through embedded digital inputs and electromechanical relay outputs. As an \"N\" type application model, this unit includes enhanced programmable capabilities and built-in communication ports for local human-machine interfaces (HMIs) and system configuration tools. The hardware relies on a low-voltage DC power grid configuration, making it well-suited for integration into standard industrial control cabinets alongside standard sensor networks and electrical motor drives.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density embedded I\/O configuration with 60 distinct control terminals.\u003c\/li\u003e\n\u003cli\u003eElectromechanical relay outputs for directly switching diverse AC and DC loads.\u003c\/li\u003e\n\u003cli\u003eIntegrated communication ports supporting interface options for programming and network telemetry.\u003c\/li\u003e\n\u003cli\u003eStandard application type controller (\"N\" model) providing comprehensive data handling functionality.\u003c\/li\u003e\n\u003cli\u003eSlotless, block-type hardware enclosure for immediate DIN rail or surface mounting.\u003c\/li\u003e\n\u003cli\u003eFlash memory backup safeguards user ladder programs and parameter states without battery reliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSorting and packaging conveyor machinery.\u003c\/li\u003e\n\u003cli\u003eDedicated material handling equipment.\u003c\/li\u003e\n\u003cli\u003eFood processing and packaging lines.\u003c\/li\u003e\n\u003cli\u003eMulti-pump municipal water management stations.\u003c\/li\u003e\n\u003cli\u003eClimate control, ventilation, and commercial HVAC panel networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePerformance and System Capacity\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eCPU Model\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCP1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eUnit Type Class\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eN = Application model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eStandard Variant\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eNone = Standard type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eTotal I\/O Capacity\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e640 points (via expansion) \/ 60 embedded points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\/Output\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTotal Embedded I\/O\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e60 I\/O points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e36 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eInput Type\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eD = DC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e24 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eOutput Type\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eR = Relays output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eDimensions (L $\\times$ W $\\times$ H)\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e8.5 cm x 19.5 cm x 9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e0.72 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e2 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eInterface \/ Terminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eUpper Terminal Block\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eScrew Terminals\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e24 VDC Power supply connections and 36 DC input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eLower Terminal Block\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eScrew Terminals\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e24 Relay output channels and functional grounding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eIntegrated Communication Ports\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSB \/ Serial Interface\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eConnection to programming workstations or local HMIs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Snap the rear alignment notch onto standard 35 mm DIN rail. Lock the unit by pressing the retention tabs upward until fully seated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Mounting:\u003c\/strong\u003e Utilize the integrated mounting screw apertures on the outer casing corners for high-vibration applications requiring structural surface installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Polarity:\u003c\/strong\u003e Double-check terminal alignment before completing the 24 VDC wiring setup. Ensure the source lines fall within the specified 20.4 to 26.4 VDC boundary to prevent component damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling and Ventilation:\u003c\/strong\u003e Maintain a clear operational space of at least 20 mm around the vertical and horizontal sides of the unit to ensure natural convection currents through the ventilation grills.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Separate high-voltage AC lines or power conductor cables from low-voltage DC inputs and serial lines to minimize industrial electromagnetic noise (EMI\/RFI).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the difference between an \"N\" type and an \"E\" type CPU in this line?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe \"N\" type (Application Model) features built-in communication ports and a more comprehensive instructions database compared to basic \"E\" types.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan this specific unit be powered by 110 or 220 VAC lines?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNo, this model requires a regulated 24 VDC power supply, functioning between an acceptable range of 20.4 to 26.4 VDC.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the capacity of the built-in digital I\/O points?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe hardware has 60 embedded points, split cleanly into 36 digital inputs and 24 relay outputs.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAre the digital outputs solid-state or electromechanical?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe unit utilizes mechanical relay outputs, allowing direct switching across a variety of voltage levels and external loads.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat programming application handles code development for this CPU?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eCX-Programmer, which is included in the unified Omron CX-One automation software installation package.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIs an independent external chassis ground connection required?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes, the functional grounding terminal must be connected to a dedicated industrial earth point using appropriate gauge wiring.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDoes this PLC require an option card to perform serial communications?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe \"N\" type CPU includes built-in communication ports, though it can be expanded further with option boards if extra links are required.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat are the physical footprint clearances of this module?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe physical base casing measurements are 8.5 cm long, 19.5 cm wide, and 9 cm high.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAre user step programs wiped if the internal battery runs dry?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe main user configuration and step logic arrays are preserved within internal non-volatile flash memory, protecting your automation code from power failures.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan expansion I\/O units be attached to this block-type controller?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eYes, the hardware can interface with supplementary expansion units to scale beyond the initial 60 built-in points.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077921530219,"sku":"CP1E-N60DR-D","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cp1e-n60dr-d-1jobqp0d4xs.png?v=1775733585","url":"https:\/\/www.plcprotech.com\/fr\/products\/cp1e-n60dr-d-omron-cp1e-cpu-unit-hardware","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}